Nissan Teana J32. Instruction — part 320

DOOR LOCK ACTUATOR

DLK-63

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

REAR LH : Component Function Check

INFOID:0000000003794855

1.

CHECK FUNCTION

1.

Use CONSULT-III to perform Active Test (“DOOR LOCK”).

2.

Touch “ALL LCK” or “ALL UNLK” to check that it works normally.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-63, "REAR LH : Diagnosis Procedure"

.

REAR LH : Diagnosis Procedure

INFOID:0000000003794856

1.

CHECK DOOR LOCK ACTUATOR OUTPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly LH.

3.

Check voltage between rear door lock assembly LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace rear door lock assembly LH. Refer to

DLK-202, "DOOR ASSEMBLY : Removal and

Installation"

.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and rear door lock assembly LH harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-78, "Removal and Installation"

.

NO

>> Repair or replace harness.

REAR RH

REAR RH : Description

INFOID:0000000003794857

Locks/unlocks the door with the signal from BCM.

REAR RH : Component Function Check

INFOID:0000000003794858

1.

CHECK FUNCTION

(+)

(–)

Condition

Voltage (V)

(Approx.)

Rear door lock assembly LH

Connector

Terminal

D85

1

Ground

Door lock and
unlock switch

LOCK

0

Battery voltage

0

2

UNLOCK

0

Battery voltage

0

BCM

Rear door lock assembly LH

Continuity

Connector

Terminal

Connector

Terminal

M119

8

D85

1

Existed

10

2

BCM

Ground

Continuity

Connector

Terminal

M119

8

Not existed

10

DLK-64

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

DOOR LOCK ACTUATOR

1.

Use CONSULT-III to perform Active Test (“DOOR LOCK”).

2.

Touch “ALL LCK” or “ALL UNLK” to check that it works normally.

Is the inspection result normal?

YES

>> Door lock actuator is OK.

NO

>> Refer to

DLK-64, "REAR RH : Diagnosis Procedure"

.

REAR RH : Diagnosis Procedure

INFOID:0000000003794859

1.

CHECK DOOR LOCK ACTUATOR OUTPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect rear door lock assembly RH.

3.

Check voltage between rear door lock assembly RH harness connector and ground.

Is the inspection result normal?

YES

>> Replace rear door lock assembly RH. Refer to

DLK-208, "DOOR ASSEMBLY : Removal and

Installation"

.

NO

>> GO TO 2.

2.

CHECK DOOR LOCK ACTUATOR CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and rear door lock assembly RH harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-78, "Removal and Installation"

.

NO

>> Repair or replace harness.

(+)

(–)

Condition of door lock and

unlock switch

Voltage (V)

(Approx.)

Rear door lock assembly RH

Connector

Terminal

D105

1

Ground

UNLOCK

0

Battery voltage

0

2

LOCK

0

Battery voltage

0

BCM

Rear door lock assembly RH

Continuity

Connector

Terminal

Connector

Terminal

M119

8

D105

2

Existed

10

1

BCM

Ground

Continuity

Connector

Terminal

M119

8

Not Existed

10

TRUNK LID OPENER ACTUATOR

DLK-65

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

C

D

E

F

G

H

I

J

L

M

A

B

DLK

N

O

P

TRUNK LID OPENER ACTUATOR

Description

INFOID:0000000003794860

Trunk lid opener actuator open trunk lid from BCM.

Component Function Check

INFOID:0000000003794861

1.

CHECK FUNCTION

1.

Perform Active Test (“TRUNK/GLASS HATCH”) with CONSULT-III.

2.

Touch “OPEN” and check that trunk lid opens.

Is the inspection result normal?

YES

>> Trunk lid opener actuator is OK.

NO

>> Refer to

DLK-65, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000003794862

1.

CHECK TRUNK LID OPENER INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect trunk lid lock assembly.

3.

Check voltage between trunk lid lock assembly harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 3.

NO

>> GO TO 2.

2.

CHECK TRUNK LID OPENER ACTUATOR CIRCUIT

1.

Disconnect BCM connector.

2.

Check continuity between BCM harness connector and trunk lid lock assembly (trunk lid opener actuator)
harness connector.

3.

Check continuity between BCM harness connector and ground.

Is the inspection result normal?

YES

>> Replace BCM. Refer to

BCS-78, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK TRUNK LID OPENER ACTUATOR GROUND CIRCUIT

Check continuity between trunk lid lock assembly (trunk lid opener actuator) harness connector and ground.

(+)

(–)

Condition

Voltage (V)

(Approx.)

Trunk lid lock assembly

(trunk lid opener actuator)

Connector

Terminal

T5

2

Ground

Trunk lid opener switch is ON

0

Battery voltage

0

BCM

Trunk lid lock assembly

(trunk lid opener actuator)

Continuity

Connector

Terminal

Connector

Terminal

M120

23

T5

2

Existed

BCM

Ground

Continuity

Connector

Terminal

M120

23

Not existed

DLK-66

< COMPONENT DIAGNOSIS >

[WITH INTELLIGENT KEY SYSTEM]

TRUNK LID OPENER ACTUATOR

Is the inspection normal?

YES

>> Replace trunk lid lock assembly. Refer to

DLK-214, "TRUNK LID ASSEMBLY : Removal and

Installation"

NO

>> Repair or replace harness.

Trunk lid lock assembly

Ground

Continuity

Connector

Terminal

T5

3

Existed