Nissan Leaf. Instruction — part 1203
P325C DRIVE MOTOR A POSITION
TMS-93
< DTC/CIRCUIT DIAGNOSIS >
D
E
F
G
H
I
J
K
L
M
A
B
TMS
N
O
P
P325C DRIVE MOTOR A POSITION
DTC Logic
INFOID:0000000010120999
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always power switch OFF and wait
at least 10 seconds before conducting the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
With CONSULT
1. Power switch OFF and wait for 10 seconds or more.
2. Power switch ON and wait for 10 seconds or more.
3. Check DTC.
Is “P325C” detected?
YES
>> Go to
.
NO-1 >> To check malfunction symptom before repair: Refer to
GI-53, "Intermittent Incident"
NO-2 >> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010121000
1.
RECORDING THE TRACTION MOTOR RESOLVER OFSET THAT IS STAMPED ON THE TRACTION MO-
TOR
1. Power switch OFF.
2. Write down the traction motor resolver correction value inscribed on traction motor.
NOTE:
For the traction motor stamp location, refer to
.
>> GO TO 2.
2.
WRITING OF TRACTION MOTOR RESOLVER OFFSET
Write the traction motor resolver offset to the traction motor inverter. Refer to
.
>> GO TO 3.
3.
READING AND CHECKING TRACTION MOTOR RESOLVER OFFSET
1. Power switch OFF and wait for 10 seconds or more.
2. Power switch ON.
3. Use CONSULT to read the traction motor offset that is written to the traction motor inverter.
4. Check whether or not the read value matches the value which is stamped on the traction motor.
>> INSPECTION END
DTC
CONSULT screen terms
(Trouble diagnosis content)
Malfunction detected condition
Possible causes
P325C
DRIVE MOTOR A POSITION
(Drive Motor “A” Position Value
Unrecorded)
When correction value memorized by traction
motor inverter is the initial value
The traction motor resolver offset
has not been written to the traction
motor inverter
TMS-94
< DTC/CIRCUIT DIAGNOSIS >
P325D DRIVE MOTOR A POSITION
P325D DRIVE MOTOR A POSITION
DTC Logic
INFOID:0000000010121001
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always power switch OFF and wait
at least 10 seconds before conducting the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
With CONSULT
1. Power switch ON and wait for 10 seconds or more.
2. Check DTC.
Is “P325D” detected?
YES
>> Go to
NO-1 >> To check malfunction symptom before repair: Refer to
GI-53, "Intermittent Incident"
.
NO-2 >> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010121002
1.
REPLACE TRACTION MOTOR INVERTER
Replace the traction motor inverter. Refer to
TMS-103, "Removal and Installation"
.
>> END
DTC
CONSULT screen terms
(Trouble diagnosis content)
Malfunction detected condition
Possible causes
P325D
DRIVE MOTOR A POSITION
(Drive Motor “A” Position Offset
Value Error)
If the traction motor resolver angle data stored by
the traction motor inverter is abnormal
Traction motor inverter
P325E DRIVE MOTOR A POSITION
TMS-95
< DTC/CIRCUIT DIAGNOSIS >
D
E
F
G
H
I
J
K
L
M
A
B
TMS
N
O
P
P325E DRIVE MOTOR A POSITION
DTC Logic
INFOID:0000000010121003
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always power switch OFF and wait
at least 10 seconds before conducting the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
With CONSULT
1. Power switch ON and wait for 10 seconds or more.
2. Check DTC.
Is “P325E” detected?
YES
>> Go to
.
NO-1 >> To check malfunction symptom before repair: Refer to
GI-53, "Intermittent Incident"
NO-2 >> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010121004
1.
REPLACE TRACTION MOTOR INVERTER
Replace the traction motor inverter. Refer to
TMS-103, "Removal and Installation"
.
>> END
DTC
CONSULT screen terms
(Trouble diagnosis content)
Malfunction detected condition
Possible causes
P325E
DRIVE MOTOR A POSITION
(Drive Motor “A” Position Value
Error 1)
If the traction motor resolver offset stored by the
traction motor inverter is abnormal
Traction motor inverter
TMS-96
< DTC/CIRCUIT DIAGNOSIS >
P325F DRIVE MOTOR A POSITION
P325F DRIVE MOTOR A POSITION
DTC Logic
INFOID:0000000010121005
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PRECONDITIONING
If “DTC CONFIRMATION PROCEDURE” has been previously conducted, always power switch OFF and wait
at least 10 seconds before conducting the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
With CONSULT
1. Power switch ON and wait for 10 seconds or more.
2. Check DTC.
Is “P325F” detected?
YES
>> Go to
NO-1 >> To check malfunction symptom before repair: Refer to
GI-53, "Intermittent Incident"
.
NO-2 >> Confirmation after repair: INSPECTION END
Diagnosis Procedure
INFOID:0000000010121006
1.
REPLACE TRACTION MOTOR INVERTER
Replace the traction motor inverter. Refer to
TMS-103, "Removal and Installation"
.
>> END
DTC
CONSULT screen terms
(Trouble diagnosis content)
Malfunction detected condition
Possible causes
P325F
DRIVE MOTOR A POSITION
(Drive Motor “A” Position Value
Error)
If the traction motor resolver offset stored by the
traction motor inverter is abnormal
Traction motor inverter
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.