Nissan Qashqai (2007-2010). Manual — part 1132
BACK DOOR OPENER SWITCH
DLK-607
< COMPONENT DIAGNOSIS >
[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BACK DOOR OPENER SWITCH
Description
INFOID:0000000001115824
Sends the back door opening signal to BCM.
Component Function Check
INFOID:0000000001115825
1.
CHECK FUNCTION
With CONSULT-III
Check “TRNK OPNR SW” in “Data Monitor” mode with CONSULT-III.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-607, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000001115826
1.
CHECK BCM INPUT SIGNAL
Check voltage between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 2.
2.
CHECK BACK DOOR OPENER SWITCH CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect BCM connector and back door opener switch connector.
3.
Check continuity between BCM connector and back door opener switch connector.
4.
Check continuity between BCM connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
Check voltage between BCM connector and ground.
Monitor item
Condition
TRNK OPNR SW
Back door opener switch is pressed
:ON
Back door opener switch is released
:OFF
Terminals
Condition of back door
opener switch
Voltage (V)
(Approx.)
(+)
(–)
BCM connector
Terminal
M65
12
Ground
Pressed
0
Released
Battery voltage
BCM connector
Terminal
Back door opener switch
connector
Terminal
Continuity
M65
12
D186
1
Exists
BCM connector
Terminal
Ground
Continuity
M65
12
Does not exist
DLK-608
< COMPONENT DIAGNOSIS >
[WITHOUT I-KEY & SUPER LOCK]
BACK DOOR OPENER SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Replace BCM. Refer to
4.
CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT
Check continuity between back door opener switch connector and ground.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace harness.
5.
CHECK BACK DOOR OPENER SWITCH
Check back door opener switch.
Refer to
DLK-608, "Component Inspection"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> Replace back door opener switch. Refer to
Component Inspection
INFOID:0000000001115827
1.
CHECK BACK DOOR OPENER SWITCH
Check back door opener switch.
Is the inspection result normal?
YES
>> Back door opener switch is OK.
NO
>> Replace back door opener switch. Refer to
Terminals
Voltage (V)
(Approx.)
(+)
(–)
BCM connector
Terminal
M65
12
Ground
Battery voltage
Back door opener switch
connector
Terminal
Ground
Continuity
D186
2
Exists
Back door opener switch connector
Terminal
Back door opener switch condition
Continuity
D186
1
2
Pressed
Exists
Released
Does not exist
BUZZER (COMBINATION METER)
DLK-609
< COMPONENT DIAGNOSIS >
[WITHOUT I-KEY & SUPER LOCK]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BUZZER (COMBINATION METER)
Description
INFOID:0000000001099053
Performs operation method guide and warning with buzzer.
Component Function Check
INFOID:0000000001099054
1.
CHECK FUNCTION
With CONSULT-III
1.
Check the operation with “WARNING BUZZER” in the Active Test.
2.
Touch “KEY REMINDER WARN” on screen.
Is the inspection result normal?
Yes
>> Warning buzzer into combination meter is OK.
No
>> Refer to
DLK-609, "Diagnosis Procedure"
Diagnosis Procedure
INFOID:0000000001099055
1.
CHECK METER BUZZER CIRCUIT
WCS-20, "Component Function Check"
.
Is the inspection result normal?
Yes
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
No
>> Repair or replace meter buzzer circuit.
DLK-610
< COMPONENT DIAGNOSIS >
[WITHOUT I-KEY & SUPER LOCK]
HAZARD WARNING LAMPS
HAZARD WARNING LAMPS
Description
INFOID:0000000001099056
Perform answer-back for each operation with number of blinks.
Component Function Check
INFOID:0000000001099057
1.
CHECK FUNCTION
With CONSULT-III
Check hazard warning lamp “FLASHER” in Active test.
Is the inspection result normal?
YES
>> Hazard warning lamp circuit is OK.
NO
>> Refer to
DLK-610, "Diagnosis Procedure"
.
Diagnosis Procedure
INFOID:0000000001099058
1.
CHECK HAZARD SWITCH CIRCUIT
Check hazard switch circuit.
Refer to
EXL-72, "Component Function Check"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-39, "Intermittent Incident"
.
NO
>> Repair or replace hazard warning switch circuit.