Nissan Quest E52. Instruction — part 373
DLK-206
< DTC/CIRCUIT DIAGNOSIS >
B2414 AUTOMATIC SLIDING DOOR MOTOR
B2414 AUTOMATIC SLIDING DOOR MOTOR
SLIDING DOOR LH
SLIDING DOOR LH : DTC Logic
INFOID:0000000009649103
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON.
2.
Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR” using CONSULT.
Is DTC detected?
YES
>> Refer to
DLK-206, "SLIDING DOOR LH : Diagnosis Procedure"
NO
>> INSPECTION END
SLIDING DOOR LH : Diagnosis Procedure
INFOID:0000000009649104
1.
CHECK SLIDING DOOR CONTROL UNIT LH POWER SUPPLY
Check sliding door control unit LH power supply.
Refer to
DLK-239, "SLIDING DOOR CONTROL UNIT : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK CLUTCH
1.
Select “AUTO SLDE DOOR” using CONSULT.
2.
Select “CLUTCH” in “ACTIVE TEST” mode.
3.
Touch “HOLD” or “RELEASE” to check that it works normally.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 4.
3.
CHECK AUTOMATIC SLIDING DOOR MOTOR OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic sliding door unit LH connector.
3.
Check voltage between automatic sliding door unit LH harness connector and ground.
Is the inspection result normal?
DTC
CONSULT display
description
DTC detecting condition
Possible cause
B2414
ASD MTR TIME OUT
When the sliding door control unit and sliding door
motor operate in the same direction for 15 seconds
or more continuously
• Clutch
• Automatic sliding door motor
• Sliding door control unit
• Battery voltage (low battery)
(+)
(–)
Condition
Voltage
Automatic sliding door unit LH
Connector
Terminal
B33
3
Ground
Sliding door LH
Auto open opera-
tion
9 – 16 V
Other than above
0 – 1.5 V
4
Auto close opera-
tion
9 – 16 V
Other than above
0 – 1.5 V
B2414 AUTOMATIC SLIDING DOOR MOTOR
DLK-207
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
YES
>> Replace sliding door control unit LH. Refer to
DLK-500, "LH : Removal and Installation"
NO
>> GO TO 5.
4.
CHECK CLUTCH CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect sliding door control unit LH connector and automatic sliding door unit LH connector.
3.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
4.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit LH.
NO
>> Repair or replace harness.
5.
CHECK AUTOMATIC SLIDING DOOR MOTOR CIRCUIT
1.
Disconnect sliding door control unit LH connector.
2.
Check continuity between sliding door control unit LH harness connector and automatic sliding door unit
LH harness connector.
3.
Check continuity between sliding door control unit LH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit LH.
NO
>> Repair or replace harness.
SLIDING DOOR RH
SLIDING DOOR RH : DTC Logic
INFOID:0000000009649105
DTC DETECTION LOGIC
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B47
44
B33
1
Existed
47
2
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B47
44
Not existed
47
Sliding door control unit LH
Automatic sliding door unit LH
Continuity
Connector
Terminal
Connector
Terminal
B47
43
B33
3
Existed
46
4
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B47
43
Not existed
46
DTC
CONSULT display
description
DTC detecting condition
Possible cause
B2414
ASD MTR TIME OUT
When the sliding door control unit and sliding door
motor operate in the same direction for 15 seconds
or more continuously
• Clutch
• Automatic sliding door motor
• Sliding door control unit
• Battery voltage (low battery)
DLK-208
< DTC/CIRCUIT DIAGNOSIS >
B2414 AUTOMATIC SLIDING DOOR MOTOR
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1.
Turn ignition switch ON.
2.
Check “Self Diagnostic Result” mode of “AUTO SLIDE DOOR RIGHT” using CONSULT.
Is DTC detected?
YES
>> Refer to
DLK-208, "SLIDING DOOR RH : Diagnosis Procedure"
NO
>> INSPECTION END
SLIDING DOOR RH : Diagnosis Procedure
INFOID:0000000009649106
1.
CHECK SLIDING DOOR CONTROL UNIT RH POWER SUPPLY
Check sliding door control unit RH power supply.
Refer to
DLK-239, "SLIDING DOOR CONTROL UNIT : Diagnosis Procedure"
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace the malfunctioning parts.
2.
CHECK CLUTCH
1.
Select “AUTO SLDE DOOR RIGHT” using CONSULT.
2.
Select “CLUTCH” in “ACTIVE TEST” mode.
3.
Touch “HOLD” or “RELEASE” to check that it works normally.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 4.
3.
CHECK AUTOMATIC SLIDING DOOR MOTOR OUTPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic sliding door unit RH connector.
3.
Check voltage between automatic sliding door unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace sliding door control unit RH. Refer to
DLK-500, "RH : Removal and Installation"
NO
>> GO TO 5.
4.
CHECK CLUTCH CIRCUIT
1.
Turn ignition switch OFF.
2.
Disconnect sliding door control unit RH connector and automatic sliding door unit RH connector.
3.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
4.
Check continuity between sliding door control unit RH harness connector and ground.
(+)
(–)
Condition
Voltage
Automatic sliding door unit RH
Connector
Terminal
B245
3
Ground
Sliding door RH
Auto close opera-
tion
9 – 16 V
Other than above
0 – 1.5 V
4
Auto open opera-
tion
9 – 16 V
Other than above
0 – 1.5 V
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B249
44
B245
1
Existed
47
2
B2414 AUTOMATIC SLIDING DOOR MOTOR
DLK-209
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace automatic sliding door unit RH.
NO
>> Repair or replace harness.
5.
CHECK AUTOMATIC SLIDING DOOR MOTOR CIRCUIT
1.
Disconnect sliding door control unit RH connector.
2.
Check continuity between sliding door control unit RH harness connector and automatic sliding door unit
RH harness connector.
3.
Check continuity between sliding door control unit RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace automatic sliding door unit RH.
NO
>> Repair or replace harness.
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B249
44
Not existed
47
Sliding door control unit RH
Automatic sliding door unit RH
Continuity
Connector
Terminal
Connector
Terminal
B249
43
B245
4
Existed
46
3
Sliding door control unit RH
Ground
Continuity
Connector
Terminal
B249
43
Not existed
46
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.