Nissan Quest E52. Instruction — part 392
DLK-282
< DTC/CIRCUIT DIAGNOSIS >
AUTOMATIC BACK DOOR CLOSE SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
DLK-282, "Component Inspection"
.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic back door close switch.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000009649204
1.
CHECK AUTOMATIC BACK DOOR CLOSE SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect automatic back door close switch connector.
3.
Check continuity between automatic back door close switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace automatic back door close switch.
Automatic back door close switch
Ground
Continuity
Connector
Terminal
D169
2
Existed
Automatic back door close switch
Condition
Continuity
Terminal
1
2
Automatic back door
close switch
Pressed
Existed
Released
Not existed
AUTOMATIC DOOR MAIN SWITCH
DLK-283
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
AUTOMATIC DOOR MAIN SWITCH
AUTOMATIC BACK DOOR CONTROL MODULE
AUTOMATIC BACK DOOR CONTROL MODULE : Component Function Check
INFOID:0000000009649205
1.
CHECK FUNCTION
1.
Select “AUTO BACK DOOR” using CONSULT.
2.
Select “MAIN SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Automatic door main switch is OK.
NO
>> Refer to
DLK-283, "AUTOMATIC BACK DOOR CONTROL MODULE : Diagnosis Procedure"
.
AUTOMATIC BACK DOOR CONTROL MODULE : Diagnosis Procedure
INFOID:0000000009649206
1.
CHECK AUTOMATIC DOOR MAIN SWITCH INPUT SIGNAL
1.
Turn ignition switch OFF.
2.
Disconnect automatic door main switch connector.
3.
Check voltage between automatic door main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC DOOR MAIN SWITCH CIRCUIT
1.
Disconnect automatic back door control module connector.
2.
Check continuity between automatic back door control module harness connector and automatic door
main switch harness connector.
3.
Check continuity between automatic back door control module connector and ground.
Is the inspection result normal?
YES
>> Replace automatic back door control module. Refer to
DLK-495, "Removal and Installation"
.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC DOOR MAIN SWITCH GROUND CIRCUIT
Check continuity between automatic door main switch connector and ground.
Monitor item
Condition
Status
MAIN SW
Automatic door main switch
ON
ON
OFF
OFF
(+)
(–)
Voltage
Automatic door main switch
Connector
Terminal
M29
1
Ground
9 - 16 V
Automatic back door control module
Automatic door main switch
Continuity
Connector
Terminal
Connector
Terminal
B8
17
M29
1
Existed
Automatic back door control module
Ground
Continuity
Connector
Terminal
B8
17
Not existed
DLK-284
< DTC/CIRCUIT DIAGNOSIS >
AUTOMATIC DOOR MAIN SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC DOOR MAIN SWITCH
DLK-284, "AUTOMATIC BACK DOOR CONTROL MODULE : Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic door main switch.
5.
CHECK INTERMITTENT INCIDENT
GI-42, "Intermittent Incident"
>> INSPECTION END
AUTOMATIC BACK DOOR CONTROL MODULE : Component Inspection
INFOID:0000000009649207
1.
CHECK AUTOMATIC DOOR MAIN SWITCH
1.
Turn ignition switch OFF.
2.
Disconnect automatic door main switch connector.
3.
Check continuity between automatic door main switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace automatic door main switch.
SLIDING DOOR CONTROL UNIT
SLIDING DOOR CONTROL UNIT : Component Function Check
INFOID:0000000009649208
1.
CHECK FUNCTION
1.
Select “AUTO SLDE DOOR” (LH) or “AUTO SLDE DOOR RIGHT” (RH) using CONSULT.
2.
Select “MAIN SW” in “DATA MONITOR” mode.
3.
Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Automatic door main switch is OK.
NO
>> Refer to
DLK-284, "SLIDING DOOR CONTROL UNIT : Diagnosis Procedure"
SLIDING DOOR CONTROL UNIT : Diagnosis Procedure
INFOID:0000000009649209
1.
CHECK AUTOMATIC DOOR MAIN SWITCH POWER SUPPLY
1.
Turn ignition switch OFF.
2.
Disconnect automatic door main switch connector.
Automatic door main switch
Ground
Continuity
Connector
Terminal
M29
3
Existed
Automatic door main switch
Condition
Continuity
Terminal
1
3
Automatic door main
switch
ON
Existed
OFF
Not existed
Monitor item
Condition
Status
MAIN SW
Automatic door main switch
ON
ON
OFF
OFF
AUTOMATIC DOOR MAIN SWITCH
DLK-285
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
3.
Check voltage between automatic door main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK AUTOMATIC DOOR MAIN SWITCH CIRCUIT
1.
Disconnect sliding door control unit connector.
2.
Check continuity between sliding door control unit harness connector and automatic door main switch har-
ness connector.
Sliding door LH
Sliding door RH
3.
Check continuity between sliding door control unit connector and ground.
Sliding door LH
Sliding door RH
Is the inspection result normal?
YES
>> Replace sliding door control unit.
NO
>> Repair or replace harness.
3.
CHECK AUTOMATIC DOOR MAIN SWITCH GROUND CIRCUIT
Check continuity between automatic door main switch connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK AUTOMATIC DOOR MAIN SWITCH
DLK-286, "SLIDING DOOR CONTROL UNIT : Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace automatic door main switch.
(+)
(–)
Voltage
(Approx.)
Automatic door main switch
Connector
Terminal
M29
1
Ground
8 – 16 V
Sliding door control unit LH
Automatic door main switch
Continuity
Connector
Terminal
Connector
Terminal
B45
1
M29
1
Existed
Sliding door control unit LH
Automatic door main switch
Continuity
Connector
Terminal
Connector
Terminal
B247
1
M29
1
Existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B45
1
Not existed
Sliding door control unit LH
Ground
Continuity
Connector
Terminal
B247
1
Not existed
Automatic door main switch
Ground
Continuity
Connector
Terminal
M29
3
Existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст