Nissan Quest E52. Instruction — part 982

PWC-40

< DTC/CIRCUIT DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

SLIDING DOOR POWER WINDOW SWITCH

Is the inspection result normal?

YES

>> Replace power window main switch. Refer to

PWC-68, "Removal and Installation"

.

NO

>> Repair or replace harness.

3.

CHECK SLIDING DOOR POWER WINDOW SWITCH

Check sliding door power window switch.
Refer to

PWC-40, "Component Inspection"

.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to

GI-42, "Intermittent Incident"

.

NO

>> Replace sliding door power window switch. Refer to

PWC-69, "Removal and Installation"

.

Component Inspection

INFOID:0000000009653302

1.

CHECK SLIDING DOOR POWER WINDOW SWITCH

1.

Turn ignition switch OFF.

2.

Disconnect sliding door power window switch connector.

3.

Check sliding door power window switch terminals under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace sliding door power window switch. Refer to

PWC-69, "Removal and Installation"

.

Sliding door power window switch

Ground

Continuity

Connector

Terminal

LH

D88

2

Not existed

3

RH

D108

2

3

Sliding door power window switch

Condition

Continuity

Terminal

1

5

UP

Existed

3

4

2

5

NEUTRAL

3

4

1

4

DOWN

2

5

POWER WINDOW MOTOR

PWC-41

< DTC/CIRCUIT DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

POWER WINDOW MOTOR

DRIVER SIDE

DRIVER SIDE : Component Function Check

INFOID:0000000009653303

1.

CHECK FUNCTION

Check front power window motor (driver side) operation with power window main switch.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Refer to

PWC-41, "DRIVER SIDE : Diagnosis Procedure"

.

DRIVER SIDE : Diagnosis Procedure

INFOID:0000000009653304

1.

CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front power window motor (driver side) connector.

3.

Turn ignition switch ON.

4.

Check voltage between front power window motor (driver side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front power window motor (driver side). Refer to

GW-29, "Removal and Installation"

.

NO

>> GO TO 2.

2.

CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect power window main switch connector.

3.

Check continuity between front power window motor (driver side) harness connector and power window
main switch harness connector.

4.

Check continuity between front power window motor (driver side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace power window main switch. Refer to

PWC-68, "Removal and Installation"

.

NO

>> Repair or replace harness.

PASSENGER SIDE

(+)

(-)

Condition

Voltage (V)

Front power window motor (driver side)

Connector

Terminal

D7

1

Ground

Power window main
switch
(driver side)

NEUTRAL

0 – 1

DOWN

9 – 16

2

NEUTRAL

0 – 1

UP

9 – 16

Front power window motor (driver side)

Power window main switch

Continuity

Connector

Terminal

Connector

Terminal

D7

1

D5

11

Existed

2

8

Front power window motor (driver side)

Ground

Continuity

Connector

Terminal

D7

1

Not existed

2

PWC-42

< DTC/CIRCUIT DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

POWER WINDOW MOTOR

PASSENGER SIDE : Component Function Check

INFOID:0000000009653305

1.

CHECK FUNCTION

Check front power window motor (passenger side) operation with power window main switch or front power
window switch (passenger side).

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Refer to

PWC-42, "PASSENGER SIDE : Diagnosis Procedure"

.

PASSENGER SIDE : Diagnosis Procedure

INFOID:0000000009653306

1.

CHECK FRONT POWER WINDOW MOTOR (PASSENGER SIDE) INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect front power window motor (passenger side) connector.

3.

Turn ignition switch ON.

4.

Check voltage between front power window motor (passenger side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front power window motor (passenger side). Refer to

GW-29, "Removal and Installation"

.

NO

>> GO TO 2.

2.

CHECK FRONT POWER WINDOW MOTOR (PASSENGER SIDE) CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect front power window switch (passenger side) connector.

3.

Check continuity between front power window motor (passenger side) harness connector and front power
window switch (passenger side) harness connector.

4.

Check continuity between front power window motor (passenger side) harness connector and ground.

Is the inspection result normal?

YES

>> Replace front power window switch (passenger side). Refer to

PWC-68, "Removal and Installa-

tion"

.

NO

>> Repair or replace harness.

SLIDING DOOR LH

(+)

(-)

Condition

Voltage (V)

Front power window motor (passenger side)

Connector

Terminal

D46

1

Ground

Front power window
switch
(passenger side)

NEUTRAL

0 – 1

DOWN

9 – 16

2

NEUTRAL

0 – 1

UP

9 – 16

Front power window motor (passenger side)

Front power window switch (passenger side)

Continuity

Connector

Terminal

Connector

Terminal

D46

1

D55

9

Existed

2

8

Front power window motor (passenger side)

Ground

Continuity

Connector

Terminal

D46

1

Not existed

2

POWER WINDOW MOTOR

PWC-43

< DTC/CIRCUIT DIAGNOSIS >

[FRONT WINDOW ANTI-PINCH]

C

D

E

F

G

H

I

J

L

M

A

B

PWC

N

O

P

SLIDING DOOR LH : Component Function Check

INFOID:0000000009653307

1.

CHECK FUNCTION

Check sliding door power window motor LH operation with power window main switch or sliding door power
window switch LH.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Refer to

PWC-43, "SLIDING DOOR LH : Diagnosis Procedure"

.

SLIDING DOOR LH : Diagnosis Procedure

INFOID:0000000009653308

1.

CHECK SLIDING DOOR POWER WINDOW MOTOR LH INPUT SIGNAL

1.

Turn ignition switch OFF.

2.

Disconnect sliding door power window motor LH connector.

3.

Turn ignition switch ON.

4.

Check voltage between sliding door power window motor LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door power window motor LH.

NO

>> GO TO 2.

2.

CHECK SLIDING DOOR POWER WINDOW MOTOR LH CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect sliding door power window switch LH connector.

3.

Check continuity between sliding door power window motor LH harness connector and sliding door power
window switch LH harness connector.

4.

Check continuity between sliding door power window motor LH harness connector and ground.

Is the inspection result normal?

YES

>> Replace sliding door power window switch LH. Refer to

PWC-69, "Removal and Installation"

.

NO

>> Repair or replace harness.

SLIDING DOOR RH

SLIDING DOOR RH : Component Function Check

INFOID:0000000009653309

1.

CHECK FUNCTION

(+)

(-)

Condition

Voltage (V)

Sliding door power window motor LH

Connector

Terminal

D82

1

Ground

Sliding door power
window switch LH

NEUTRAL

0 – 1

UP

9 – 16

3

NEUTRAL

0 – 1

DOWN

9 – 16

Sliding door power window motor LH

Sliding door power window switch LH

Continuity

Connector

Terminal

Connector

Terminal

D82

1

D88

5

Existed

3

4

Sliding door power window motor LH

Ground

Continuity

Connector

Terminal

D82

1

Not existed

3