Nissan Cube. Instruction — part 444

EXL-50

< DTC/CIRCUIT DIAGNOSIS >

TURN SIGNAL LAMP CIRCUIT

TURN SIGNAL LAMP CIRCUIT

Description

INFOID:0000000009945153

BCM performs the high flasher operation if any bulb or harness of the turn signal lamp circuit is open.
NOTE:
The turn signal lamp blinks at normal speed when using the hazard warning lamp.

Component Function Check

INFOID:0000000009945154

1.

CHECK TURN SIGNAL LAMP

CONSULT ACTIVE TEST

1.

Select “FLASHER” of BCM (FLASHER) active test item.

2.

With operating the test items, check that the turn signal lamps blink.

Does the turn signal lamps blink?

YES

>> Turn signal lamp circuit is normal.

NO

>> Refer to

EXL-50, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009945155

1.

CHECK TURN SIGNAL LAMP BULB

Check the applicable lamp bulb.

Is the bulb normal?

YES

>> GO TO 2.

NO

>> Replace the bulb.

2.

CHECK TURN SIGNAL LAMP OPEN CIRCUIT

1.

Turn the ignition switch OFF.

2.

Disconnect BCM connector.

3.

Disconnect the front turn signal lamp connector, side turn signal lamp connector, or the rear combination
lamp connector.

4.

Check continuity between the BCM harness connector and the front turn signal lamp, side turn signal
lamp or the rear combination lamp harness connector.

-

With Intelligent Key

Front turn signal lamp

Side turn signal lamp

LH

: Turn signal lamps (LH) blink

RH

: Turn signal lamps (RH) blink

Off

: Turn signal lamps OFF

BCM

Front turn signal lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M70

61

E46

1

Existed

LH

60

E27

BCM

Side turn signal lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M70

61

E40

1

Existed

LH

60

E23

TURN SIGNAL LAMP CIRCUIT

EXL-51

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

Rear turn signal lamp

-

Without Intelligent Key

Front turn signal lamp

Side turn signal lamp

Rear turn signal lamp

Does continuity exist?

YES

>> GO TO 3.

NO

>> Repair the harnesses or connectors.

3.

CHECK TURN SIGNAL LAMP SHORT CIRCUIT

Check continuity between the BCM harness connector and the ground.

With Intelligent Key

Without Intelligent Key

Does continuity exist?

YES

>> Repair the harnesses or connectors.

NO

>> GO TO 4.

4.

CHECK TURN SIGNAL LAMP GROUND OPEN CIRCUIT

Check continuity between the BCM harness connector and the front turn signal lamp, side turn signal lamp or
the rear combination lamp and the ground.

BCM

Rear combination lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M70

61

B59

4

Existed

LH

60

B80

BCM

Front turn signal lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M67

61

E46

1

Existed

LH

60

E27

BCM

Side turn signal lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M67

61

E40

1

Existed

LH

60

E23

BCM

Rear combination lamp

Continuity

Connector

Terminal

Connector

Terminal

RH

M67

61

B59

4

Existed

LH

60

B80

BCM

Ground

Continuity

Connector

Terminal

RH

M70

61

Not existed

LH

60

BCM

Ground

Continuity

Connector

Terminal

RH

M67

61

Not existed

LH

60

EXL-52

< DTC/CIRCUIT DIAGNOSIS >

TURN SIGNAL LAMP CIRCUIT

Front turn signal lamp

Side turn signal lamp

Rear turn signal lamp

Does continuity exist?

YES

>> Replace BCM. Refer to

BCS-88, "Removal and Installation"

(with Intelligent Key) or

BCS-155,

"Removal and Installation"

(without Intelligent Key).

NO

>> Repair the harnesses or connectors.

Front turn signal lamp

Ground

Continuity

Connector

Terminal

RH

E46

2

Existed

LH

E27

Side turn signal lamp

Ground

Continuity

Connector

Terminal

RH

E40

2

Existed

LH

E23

Rear combination lamp

Ground

Continuity

Connector

Terminal

RH

B59

3

Existed

LH

B80

OPTICAL SENSOR

EXL-53

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

M

A

B

EXL

N

O

P

OPTICAL SENSOR

Description

INFOID:0000000009945156

Optical sensor converts the outside brightness (lux) to voltage and transmits the optical sensor signal to BCM.

Component Function Check

INFOID:0000000009945157

1.

CHECK OPTICAL SENSOR SIGNAL BY CONSULT

CONSULT DATA MONITOR

1.

Turn the ignition switch ON.

2.

Select “OPTISEN (DTCT)” of BCM (HEADLAMP) data monitor item.

3.

Turn the lighting switch AUTO.

4.

With the optical sensor illuminating, check the monitor status.

*: Illuminates the optical sensor. The value may be less than the standard value if brightness is weak.

Is the item status normal?

YES

>> Optical sensor is normal.

NO

>> Refer to

EXL-53, "Diagnosis Procedure"

.

Diagnosis Procedure

INFOID:0000000009945158

1.

CHECK OPTICAL SENSOR POWER SUPPLY INPUT

1.

Turn the ignition switch ON.

2.

Turn the lighting switch AUTO.

3.

Check the voltage between the optical sensor harness connector and the ground.

Is the measurement value normal?

YES

>> GO TO 2.

NO

>> GO TO 4.

2.

CHECK OPTICAL SENSOR GROUND INPUT

Check the voltage between the optical sensor harness connector and the ground.

Is the measurement value normal?

YES

>> GO TO 3.

NO

>> GO TO 6.

3.

CHECK OPTICAL SENSOR SIGNAL OUTPUT

Monitor item

Condition

Voltage (Approx.)

OPTISEN
(DTCT)

Optical
sensor

When illuminating

3.1 V or more *

When shutting off light

0.6 V or less

Terminals

Voltage

(Approx.)

(+)

(

)

Optical sensor

Ground

Connector

Terminal

M17

1

5 V

Terminals

Voltage

(Approx.)

(+)

(

)

Optical sensor

Ground

Connector

Terminal

M17

3

0 V