Nissan March K13. Instruction — part 538
PG-140
< BASIC INSPECTION >
BATTERY CHARGING CHART
• Keep battery away from open flame while it is being charged.
• When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
• If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tem-
perature is below 55
°
C (131
°
F).
Standard Charge
INFOID:0000000005911879
1.
DETERMINE INITIAL CHARGING CURRENT
1.
Determine initial charging current from specific gravity.
2.
Check battery type and determine the specified current using the table.
NOTE:
After starting charging, adjustment of charging current is not necessary.
Initial Charging Current Setting (Standard Charge)
>> GO TO 2.
2.
CHARGE BATTERY
Charge battery for 8 hours.
>> GO TO 3.
3.
CHECKING SPECIFIC GRAVITY
Check specific gravity. Refer to
PG-130, "How to Handle Battery"
Is the specific gravity 1.240 or more?
YES
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to
.
NO
>> GO TO 4.
4.
CONDUCT ADDITIONAL CHARGE
Add charging time depending on specific gravity.
Additional Charge (Standard Charge)
>> Complete standard charge. Perform “CAPACITY TEST”. Refer to
.
CAUTION:
CONVERTED SPECIFIC
GRAVITY
BATTERY TYPE
28
B19
L
/R
34
B19
L
/R
46
B24
L
/R
55
B24
L
/R
50
D23
L
/R
55
D23
L
/R
025 [YUASA type code]
027 [YUASA type code]
80
D23
L
/R
65
D26
L
/R
80
D26
L
/R
067 [YUASA type code]
096 [YUASA type code]
75
D31
L
/R
95
D31
L
/R
1
1
5
D
31
L/R
1
1
0
D
26
L/R
95
E41
L
/R
13
0E4
1
L
/R
1.100 - 1.130
4.0 (A)
5.0 (A)
6.0 (A)
7.0 (A)
8.0
(A)
9.0 (A)
13.0
(A)
1.130 - 1.160
3.0 (A)
4.0 (A)
5.0 (A)
6.0 (A)
7.0
(A)
8.0 (A)
11.0
(A)
1.160 - 1.190
2.0 (A)
3.0 (A)
4.0 (A)
5.0 (A)
6.0
(A)
7.0 (A)
9.0
(A)
1.190 - 1.220
2.0 (A)
2.0 (A)
3.0 (A)
4.0 (A)
5.0
(A)
5.0 (A)
7.0
(A)
SPECIFIC GRAVITY
CHARGING TIME (h)
Below 1.150
3.5
1.150 - 1.200
2.5
1.200 - 1.240
1.5
PG
BATTERY CHARGING CHART
PG-141
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
• Never use standard charge method on a battery whose specific gravity is less than 1.100.
• Set charging current to value specified in “Initial Charging Current Setting (Standard Charge)”. If
charger is not capable of producing specified current value, set its charging current as close to that
value as possible.
• Keep battery away from open flame while it is being charged.
• When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
• If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tem-
perature is below 55
°
C (131
°
F).
Quick Charge
INFOID:0000000005911880
1.
DETERMINE INITIAL CHARGING CURRENT
1.
Determine initial charging current setting and charging time from specific gravity.
2.
Check battery type and determine the specified current using the table.
NOTE:
After starting charging, adjustment of charging current is not necessary.
Initial Charging Current Setting and Charging Time (Quick Charge)
CAUTION:
• Never use quick charge method on a battery whose specific gravity is less than 1.100.
• Set initial charging current to value specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”. If charger is not capable of producing specified current value, set its charging cur-
rent as close to that value as possible.
• Keep battery away from open flame while it is being charged.
• When connecting charger, connect leads first, then turn on charger. Never turn on charger first, as
this may cause a spark.
• Be careful of a rise in battery temperature because a large current flow is required during quick-
charge operation.
If battery temperature rises above 55
°
C (131
°
F), stop charging. Always charge battery when its tem-
perature is below 55
°
C (131
°
F).
• Never exceed the charging time specified in “Initial Charging Current Setting and Charging Time
(Quick Charge)”, because charging battery over the charging time can cause deterioration of the
battery.
>> GO TO 2.
2.
CHARGE BATTERY
Charge battery.
BATTERY TYPE
28
B1
9L/
R
34
B1
9L/
R
46
B2
4L/
R
55
B2
4L/
R
50
D2
3L
/R
55
D2
3L
/R
80
D2
3L
/R
65
D2
6L
/R
80
D2
6L
/R
0
2
5
[YUAS
A
type
cod
e
]
0
2
7
[YUAS
A
type
cod
e
]
0
6
7
[YUAS
A
type
cod
e
]
0
9
6
[YUAS
A
type
cod
e
]
75
D3
1L
/R
95
D3
1L
/R
1
1
5D31
L/
R
1
1
0D26
L/
R
95
E4
1L/
R
13
0E4
1
L
/R
CURRENT [A]
10
15
20
25
30
40
C
O
NVER
TED S
PECIFIC
GRA
V
IT
Y
1.100 -
1.130
2.5 hours
1.130 -
1.160
2.0 hours
1.160 -
1.190
1.5 hours
1.190 -
1.220
1.0 hour
Above
1.220
0.75 hour (45 min.)
PG-142
< BASIC INSPECTION >
BATTERY CHARGING CHART
>> Complete quick charge. Perform “CAPACITY TEST”. Refer to
.
PG
BATTERY
PG-143
< REMOVAL AND INSTALLATION >
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
REMOVAL AND INSTALLATION
BATTERY
Exploded View
INFOID:0000000005911881
Removal and Installation
INFOID:0000000005911882
REMOVAL
1.
Remove cover of battery positive terminal.
2.
Loosen battery terminal nuts, and disconnect both battery cables from battery terminals.
CAUTION:
When disconnecting, disconnect the battery cable from the negative terminal first.
3.
Remove battery fix frame mounting nuts and battery fix frame.
4.
Remove battery.
INSTALLATION
Install in the reverse order of removal.
CAUTION:
When connecting, connect the battery cable to the positive terminal first.
Reset electronic systems as necessary. Refer to
GI-46, "ADDITIONAL SERVICE WHEN REMOVING BAT-
TERY NEGATIVE TERMINAL : Required Procedure After Battery Disconnection"
1
: Battery fix frame
for symbols in the figure.
JSMIA0235GB