Nissan Murano Z51. Instruction — part 1047
MWI-46
< DTC/CIRCUIT DIAGNOSIS >
FUEL LEVEL SENSOR SIGNAL CIRCUIT
4.
Check continuity between combination meter harness connector terminal and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair harness or connector.
3.
CHECK FUEL LEVEL SENSOR GROUND CIRCUIT
Check continuity between fuel level sensor unit (main) harness connector terminal and combination meter har-
ness connector terminal.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Repair harness or connector.
Component Inspection
INFOID:0000000005524878
1.
REMOVE FUEL LEVEL SENSOR UNIT
Remove the fuel level sensor unit. Refer to
FL-6, "Removal and Installation"
.
>> GO TO 2.
2.
CHECK FUEL LEVEL SENSOR UNIT AND FUEL PUMP (MAIN)
Check the resistance between fuel level sensor unit and fuel pump (main).
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace fuel level sensor unit and fuel pump (main).
3.
CHECK FUEL LEVEL SENSOR UNIT (SUB)
Terminals
Continuity
(+)
(-)
Combination meter
Fuel level sensor unit (main)
Connector
Terminal
Connector
Terminal
M34
34
B40
2
Existed
Terminals
Continuity
(+)
(-)
Combination meter
Ground
Connector
Terminal
M34
34
Not existed
Terminals
Continuity
(+)
(-)
Fuel level sensor unit (main)
Combination meter
Connector
Terminal
Connector
Terminal
B40
5
M34
24
Existed
Terminals
Condition
Resistance (
Ω
)
(Approx.)
Height [mm (in)]
(Approx.)
Fuel level sensor unit
(main)
5
6
Full (A)
2.5
193 (7.6)
Empty (B)
81.5
15 (0.59)
2
7
—
0
—
JPNIA1323ZZ
MWI
FUEL LEVEL SENSOR SIGNAL CIRCUIT
MWI-47
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
Inspect the resistance of fuel level sensor unit (sub).
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace fuel level sensor unit (sub).
Terminals
Condi-
tion
Resistance (
Ω
)
(Approx.)
Height [mm (in)]
(Approx.)
Fuel level sen-
sor unit (sub)
(+)
(-)
6
7
Full (A)
2.5
198 (7.8)
Empty
(B)
45.2
10 (0.39)
JPNIA0738ZZ
MWI-48
< DTC/CIRCUIT DIAGNOSIS >
METER CONTROL SWITCH SIGNAL CIRCUIT
METER CONTROL SWITCH SIGNAL CIRCUIT
Description
INFOID:0000000005524879
Transmits the following signals to the combination meter.
Diagnosis Procedure
INFOID:0000000005524880
1.
CHECK METER CONTROL SWITCH INPUT SIGNAL
1.
Turn the ignition switch ON.
2.
Check voltage between the following terminals of the combination meter.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> GO TO 2.
2.
CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
1.
Turn the ignition switch OFF.
2.
Disconnect the combination meter and meter control switch connectors.
3.
Check continuity between combination meter harness connector terminals and meter control switch har-
ness connector terminals.
•
(Illumination control) switch signal (+)
•
(Illumination control) switch signal (–)
• Trip reset switch signal
•
(select) switch signal
•
(enter) switch is pressed
Terminals
Condition
Voltage
(Approx.)
Combination meter
(+)
(-)
Connector
Terminal
Connector
Terminal
M34
12
M34
10
When
(select) switch is pressed
0 V
Other than the above
5 V
11
When
(enter) switch is pressed
0 V
Other than the above
5 V
8
When trip reset switch is pressed
0 V
Other than the above
5 V
14
When
(illumination control) switch is pressed
0 V
Other than the above
5 V
13
When
(illumination control) switch is pressed
0 V
Other than the above
5 V
MWI
METER CONTROL SWITCH SIGNAL CIRCUIT
MWI-49
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
K
L
M
B
A
O
P
4.
Check continuity between combination meter harness connector terminals and ground.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Repair harness or connector.
Component Inspection
INFOID:0000000005524881
1.
CHECK METER CONTROL SWITCH
1.
Turn the ignition switch OFF.
2.
Disconnect the meter control switch connector.
3.
Check continuity between the following terminals of the meter control switch.
Is the inspection result normal?
YES
>> INSPECTION END
Terminals
Continuity
Combination meter
Meter control switch
(+)
(-)
Connector
Terminal
Connector
Terminal
M34
8
M83
11
Existed
10
5
11
12
12
1
13
6
14
4
Terminals
Continuity
(+)
(-)
Combination meter
Ground
Connector
Terminal
M34
8
Not existed
10
11
12
13
14
Terminal No.
Operation and status
Continuity
1
5
Press the
(select) switch
Existed
Other than the above
Not existed
12
5
Press the
(enter) switch
Existed
Other than the above
Not existed
11
5
Press the trip reset switch.
Existed
Other than the above
Not existed
4
5
Press the
(illumination control) switch
Existed
Other than the above
Not existed
6
5
Press the
(illumination control) switch
Existed
Other than the above
Not existed
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.