Nissan Juke F15. Instruction — part 1290
TM-350
< UNIT REMOVAL AND INSTALLATION >
[CVT: RE0F10B]
TRANSAXLE ASSEMBLY
INSPECTION AFTER INSTALLATION
• Check for CVT fluid leakage and check CVT fluid level. Refer to
.
• Check CVT position. Refer to
TM-233, "Inspection and Adjustment"
• Start and warm up the engine. Visually check that there is no leakage of engine coolant and CVT fluid.
ADJUSTMENT AFTER INSTALLATION
Perform “ADDITIONAL SERVICE WHEN REPLACE CONTROL VALVE OR TRANSAXLE ASSEMBLY”. Refer
to
.
TORQUE CONVERTER AND CONVERTER HOUSING OIL SEAL
TM-351
< UNIT DISASSEMBLY AND ASSEMBLY >
[CVT: RE0F10B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
UNIT DISASSEMBLY AND ASSEMBLY
TORQUE CONVERTER AND CONVERTER HOUSING OIL SEAL
Exploded View
INFOID:0000000012201050
Disassembly
INFOID:0000000012201051
1. Remove transaxle assembly. Refer to
TM-347, "Removal and Installation"
2. Remove torque converter from transaxle assembly.
CAUTION:
Never damage bush on the inside of torque converter sleeve when removing torque converter.
3. Remove converter housing oil seal using a flat-bladed screwdriver.
CAUTION:
Be careful not to scratch converter housing.
Assembly
INFOID:0000000012201052
Note the following, and install in the reverse order of removal.
• Drive converter housing oil seal (1) evenly using a drift (A) (commercial service tool) so that converter hous-
ing oil seal protrudes by the dimension (B) respectively.
Unit: mm (in)
1.
Transaxle assembly
2.
Converter housing oil seal
3.
Torque converter
: Always replace after every disassembly.
: Apply CVT fluid
SCIA7904J
Commercial service tool: A
Outer diameter: 65 (2.56)
Inner diameter: 60 (2.36)
2
: Transaxle assembly
SCIA7908J
TM-352
< UNIT DISASSEMBLY AND ASSEMBLY >
[CVT: RE0F10B]
TORQUE CONVERTER AND CONVERTER HOUSING OIL SEAL
Unit: mm (in)
NOTE:
Converter housing oil seal pulling direction is used as the refer-
ence.
• After completing installation, check for CVT fluid leakage and CVT
fluid level. Refer to
• Attach the pawl (A) of the torque converter to the drive sprocket
hole (B) on the transaxle assembly side.
CAUTION:
• Rotate the torque converter for installing torque converter.
• Never damage the bushing inside the torque converter
sleeve when installing the converter housing oil seal.
Inspection
INFOID:0000000012201053
INSPECTION AFTER INSTALLATION
• After inserting a torque converter to the CVT, check dimension (A)
with in the reference value limit.
Dimension B
1.0
± 0.5 (0.039 ± 0.020)
SCIA7909J
SCIA7907J
B
: Scale
C
: Straightedge
Dimension (A)
: Refer to
.
JPDIA0115ZZ
SERVICE DATA AND SPECIFICATIONS (SDS)
TM-353
< SERVICE DATA AND SPECIFICATIONS (SDS)
[CVT: RE0F10B]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
SERVICE DATA AND SPECIFICATIONS (SDS)
SERVICE DATA AND SPECIFICATIONS (SDS)
General Specification
INFOID:0000000012201054
Shift Characteristics
INFOID:0000000012201055
Numerical value data are reference values.
Unit: rpm
*: With Integrated Control System
NOTE:
Lock-up clutch is engaged when vehicle speed is approximately 18 km/h (11 MPH) to 90 km/h (56 MPH).
Stall Speed
INFOID:0000000012201056
Line Pressure
INFOID:0000000012201057
Unit: kPa (bar, kg/cm
2
, psi)
*: Reference values
Torque Converter
INFOID:0000000012201058
Heater Thermostat
INFOID:0000000012201059
Standard
Applied model
Engine
MR16DDT
Axle
AWD
Transaxle model
RE0F10B
Transmission gear ratio
D range
2.349 – 0.394
Reverse
1.750
Final drive
5.798
Recommended fluid and fluid capacity
Refer to
MA-11, "Fluids and Lubricants"
Throttle position
Shift pattern
CVT input speed
At 40 km/h (25 MPH)
At 60 km/h (37 MPH)
2/8
“D” position
1,500 – 3,100
1,600 – 3,400
ECO mode*
1,500 – 2,400
1,600 – 2,500
8/8
“D” position
3,300 – 4,200
4,300 – 5,200
ECO mode*
3,300 – 4,200
4,300 – 5,200
Stall speed
3,000 – 3,500 rpm
Engine speed
Line pressure
“R” and “D” positions
At idle
750 (7.50, 7.65, 108.8)
At stall
5,700 (57.00, 58.14, 826.5)
*
Dimension between end of converter housing and torque converter
14.4 mm (0.567 in)
Valve opening temperature
69 – 73
°C (156 –163°F)