Nissan Juke F15. Instruction — part 1331
TM-514
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F10D]
P0965 PRESSURE CONTROL SOLENOID B
CAUTION:
Be careful of the driving speed.
1.
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
1. Start the engine.
2. Drive the vehicle.
3. Maintain the following conditions for 20 seconds or more.
4. Stop the vehicle.
5. Check the first trip DTC.
Is “P0965”detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000012201213
1.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
Is the inspection result normal?
YES
>> Replace transaxle assembly. Refer to
TM-577, "Removal and Installation"
.
NO
>> Repair or replace malfunctioning parts.
Vehicle speed
: 40 km/h (25 MPH) or more
P0966 PRESSURE CONTROL SOLENOID B
TM-515
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F10D]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
P0966 PRESSURE CONTROL SOLENOID B
DTC Logic
INFOID:0000000012201214
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
1. Start the engine and wait for 5 seconds or more.
2. Check the first trip DTC.
Is “P0966” detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000012201215
1.
CHECK CIRCUIT BETWEEN TCM AND CVT UNIT
1. Turn ignition switch OFF.
2. Disconnect TCM connector and CVT unit connector.
3. Check continuity between TCM harness connector terminal and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace damaged parts.
2.
CHECK CIRCUIT BETWEEN CVT UNIT AND GROUND
Check continuity between CVT unit harness connector terminal and ground.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-45, "Intermittent Incident"
.
DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
Possible causes
P0966
PC SOLENOID B
(Pressure Control Solenoid B
Control Circuit Low)
When all of the following conditions are satis-
fied and this state is maintained for 0.48 sec-
onds:
• TCM power supply voltage: More than 11 V
• TCM judges that solenoid valve circuit is
shorted to ground.
• Harness or connector
(Primary pressure solenoid valve cir-
cuit shorted to ground)
• Primary pressure solenoid valve
TCM
—
Continuity
Connector
Terminal
F83
40
Ground
Not existed
CVT unit
—
Condition
Resistance
Connector
Terminal
F250
2
Ground
CVT fluid temperature: 20
°C (68°F)
5.5 – 7.0
Ω
CVT fluid temperature: 50
°C (122°F)
6.0 – 8.0
Ω
CVT fluid temperature: 80
°C (176°F)
6.5 – 8.5
Ω
TM-516
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F10D]
P0966 PRESSURE CONTROL SOLENOID B
NO
>> There is malfunction of primary pressure solenoid valve. Replace transaxle assembly. Refer to
P0967 PRESSURE CONTROL SOLENOID B
TM-517
< DTC/CIRCUIT DIAGNOSIS >
[CVT: RE0F10D]
C
E
F
G
H
I
J
K
L
M
A
B
TM
N
O
P
P0967 PRESSURE CONTROL SOLENOID B
DTC Logic
INFOID:0000000012201216
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PREPARATION BEFORE WORK
If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at
least 10 seconds, then perform the next test.
>> GO TO 2.
2.
CHECK DTC DETECTION
1. Start the engine and wait for 5 seconds or more.
2. Check the first trip DTC.
Is “P0967” detected?
YES
>> Go to
NO
>> INSPECTION END
Diagnosis Procedure
INFOID:0000000012201217
1.
CHECK CIRCUIT BETWEEN TCM AND CVT UNIT
1. Turn ignition switch OFF.
2. Disconnect TCM connector and CVT unit connector.
3. Check continuity between TCM harness connector terminal and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace damaged parts.
2.
CHECK CIRCUIT BETWEEN CVT UNIT AND GROUND
Check continuity between CVT unit harness connector terminal and ground.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-45, "Intermittent Incident"
.
DTC
CONSULT screen terms
(Trouble diagnosis content)
DTC detection condition
Possible causes
P0967
PC SOLENOID B
(Pressure Control Solenoid B
Control Circuit High)
When all of the following conditions are satis-
fied and this state is maintained for 0.2 sec-
onds:
• TCM power supply voltage: More than 11 V
• P0966 is not detected
• TCM judges that solenoid valve circuit is
open.
• Harness or connector
(Primary pressure solenoid valve cir-
cuit open or shorted to power supply)
• Primary pressure solenoid valve
TCM
CVT unit
Continuity
Connector
Terminal
Connector
Terminal
F83
40
F82
2
Existed
CVT unit
—
Condition
Resistance
Connector
Terminal
F250
2
Ground
CVT fluid temperature: 20
°C (68°F)
5.5 – 7.0
Ω
CVT fluid temperature: 50
°C (122°F)
6.0 – 8.0
Ω
CVT fluid temperature: 80
°C (176°F)
6.5 – 8.5
Ω
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст