Lexus GS300/400 (2000 year). Service manual — part 3
AC0WD–01
AC–16
–
AIR CONDITIONING
DRIVE BELT
2701
INSTALLATION
Installation is in the reverse order of removal (See page
AFTER INSTALLATION, CHECK DRIVE BELT’S INSTALLATION CONDITION
I02353
GS400:
Low Pressure
Charging Hose
High Pressure
Charging Hose
I02354
GS300:
Low Pressure
Charging Hose
High Pressure
Charging Hose
AC0WE–01
N04392
Sleeve
–
AIR CONDITIONING
MANIFOLD GAUGE SET
AC–17
2702
MANIFOLD GAUGE SET
SET ON
1.
CONNECT CHARGING HOSES TO MANIFOLD
GAUGE SET
Tighten the nuts by hand.
CAUTION:
Do not connect the wrong hoses.
2.
CONNECT QUICK DISCONNECT ADAPTERS TO
CHARGING HOSES
Tighten the nuts by hand.
3.
CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
4.
REMOVE CAPS FROM SERVICE VALVE ON REFRIG-
ERANT LINES
5.
CONNECT QUICK DISCONNECT ADAPTERS TO SER-
VICE VALVES
HINT:
Push the quick disconnect adapter onto the service valve, then
slide the sleeve of the quick disconnect adapter downward to
lock it.
AC0WF–01
N06553
AC–18
–
AIR CONDITIONING
MANIFOLD GAUGE SET
2703
SET OFF
1.
CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
2.
DISCONNECT QUICK DISCONNECT ADAPTERS
FROM SERVICE VALVES ON REFRIGERANT LINE
HINT:
Slide the sleeve of the quick disconnect adapter upward to un-
lock the adapter and remove it from the service valve.
3.
INSTALL CAPS TO SERVICE VALVES ON REFRIGER-
ANT LINES
AC0WG–01
–
AIR CONDITIONING
REFRIGERANT LINE
AC–19
2704
REFRIGERANT LINE
ON–VEHICLE INSPECTION
1.
INSPECT HOSE AND TUBE CONNECTIONS FOR LOOSENESS
2.
INSPECT HOSES AND TUBES FOR LEAKAGE
Using a gas leak detector, check for leakage of refrigerant.