Lexus RX300 (MCU15). Service manual — part 108
AX11B–01
D03284
SST
D03285
SST
D03287
SST
AX–16
–
AUTOMATIC TRANSAXLE
DIFFERENTIAL OIL SEAL
LEXUS RX300 (RM785E)
DIFFERENTIAL OIL SEAL
ON–VEHICLE REPAIR
1.
DRAIN ATF
2.
DRAIN TRANSFER OIL
3.
REMOVE LH AND RH DRIVE SHAFT
(See page SA–17)
4.
REMOVE LH AND RH SIDE OIL SEAL
Using SST, drive out both the side oil seals.
SST
09308–00010
5.
INSTALL LH SIDE OIL SEAL
(a)
Using SST and a hammer, drive in a new oil seal until its
surface is flush until the case surface.
SST
09350–32014 (09351–32111, 09351–32130)
Oil seal drive in depth: 0 ± 0.5 mm (0 ± 0.020 in.)
(b)
Coat the oil seal lip with MP grease.
6.
INSTALL RH SIDE OIL SEAL
(a)
Using SST and a hammer, drive in a new oil seal.
SST
09223–46011
Oil seal drive in depth: 1 ± 0.3 mm (0.039 ± 0.012 in.)
(b)
Coat the oil seal lip with MP grease.
7.
INSTALL LH AND RH DRIVE SHAFT
(See page SA–24)
8.
FILL TRANSFER OIL
9.
FILL ATF AND CHECK ATF LEVEL
(See page DI–144)
AX09V–01
D02962
Stop Light Switch
Key Interlock Solenoid
Shift Lock Control
Unit Assembly
–
AUTOMATIC TRANSAXLE
SHIFT LOCK SYSTEM
AX–17
LEXUS RX300 (RM785E)
SHIFT LOCK SYSTEM
COMPONENTS
AX09W–01
Q09455
Wire Harness Side
5 (IG)
4 (KLS
+
)
3 (E)
2 (STP)
1 (ACC)
Q09456
1 (KLS
+
)
2 (E)
Q09457
(–)
(+)
1 (KLS
+
)
2 (E)
AX–18
–
AUTOMATIC TRANSAXLE
SHIFT LOCK SYSTEM
LEXUS RX300 (RM785E)
INSPECTION
1.
INSPECT SHIFT LOCK CONTROL UNIT ASSEMBLY
Using a voltmeter, measure the voltage at each terminal.
HINT:
Do not disconnect the shift lock control unit assembly connec-
tor.
Terminal
Measuring Condition
Voltage (V)
1 – 3 (ACC – E)
Ignition switch ACC
10 – 14
5 – 3 (IG – E)
Ignition switch ON
10 – 14
2 – 3 (STP – E)
Depressing brake pedal
10 – 14
4 – 3 (KLS
+
– E)
(1) Ignition switch ACC and P position
(2) Ignition switch ACC and except P position
(3) Ignition switch ACC and except P position (After approx. 1 second)
0
7.5 – 11
6 – 9.5
2.
INSPECT KEY INTERLOCK SOLENOID
(a)
Disconnect the solenoid connector.
(b)
Using an ohmmeter, measure resistance between termi-
nals.
Standard resistance: 12.5 – 16.5 Ω
If resistance value is not as specified, replace the solenoid.
(c)
Apply battery positive voltage between terminals. Check
that an operation noise can be heard from the solenoid.
If the solenoid does not operated, replace the solenoid.
AX09S–03
D03250
Center Floor Carpet
Cover RH
No.2 Lower Panel
Center Floor Carpet
Cover LH
x 6
No.2 Under Cover
Lower Center Finish Panel
Lower Insert
Floor Shift Lever Assembly
Lower Center Cluster
Panel with Ornament
Hood Lock Release Lever
Lower Finish Panel
12 (120, 9)
N·m (kgf·cm, in.·lbf) : Specified torque
Lower Cluster Finish Panel
–
AUTOMATIC TRANSAXLE
FLOOR SHIFT ASSEMBLY
AX–19
LEXUS RX300 (RM785E)
FLOOR SHIFT ASSEMBLY
COMPONENTS