Ford Focus RS (2011 year). Manual — part 80
Measurements
Roof Opening Panel Control Switch
Terminals
Roof Opening Panel
Control Switch Posi-
tion
Multimeter Negative
Lead
Multimeter Positive
Lead
Less than 5 ohms
4
2
Fully Up/Close
Greater than 10,000 ohms
4
2
First detente Down/Open
Less than 5 ohms
4
2
Fully Down/Open
Less than 5 ohms
4
3
First detente Down/Open
Less than 5 ohms
4
3
Fully Down/Open
Greater than 10,000 ohms
4
3
First detente Up/Close
Less than 5 ohms
4
3
Fully Up/Close
2. If all measurements of the roof opening panel
control switch are as noted, return to the
Pinpoint Test. Otherwise install a new roof
opening panel control switch.
G330089en
501-17-
10
Roof Opening Panel
501-17-
10
DIAGNOSIS AND TESTING
Water Drainage System Check and Water Leak
Corrections(41 002 0)
1. If a drain hose blockage or obstruction is
suspected, check the drain hoses by pouring
500 ml of water into the drain trough and
checking the flow from under the vehicle
rocker panels. Attempt to clear any blockage
or obstruction using a drain clearing wire
(nylon). If the blockage or obstruction cannot
be cleared the drain hose must be removed.
For additional information,
refer to Roof
Opening Panel Front Drain Hose -
/ Roof Opening Panel Rear Drain Hose -
in
this section.
2. If a drain hose leak is suspected the drain
hose must be removed and inspected for
cracks or splits.
For additional information,
refer to Roof
Opening Panel Front Drain Hose -
/ Roof Opening Panel Rear Drain Hose -
in
this section.
G167713en
501-17-
11
Roof Opening Panel
501-17-
11
GENERAL PROCEDURES
Roof Opening Panel Alignment(41 113 0)
1. NOTE: The roof opening panel must be in
the closed position for alignment.
Starting at the rear of the roof opening panel,
remove the roof opening panel guide arm
covers (left-hand side shown).
1. Release the lower clip.
2. Release the upper clip.
TIE39805
1
2
2. Adjust the rear edge of the roof opening
panel glass.
1. Loosen the retaining screws on both sides
(left-hand side shown).
2. Push the rear edge up or down to give the
correct alignment (flush to + 1 mm).
E49456
2
2
1
3. Make sure that the roof opening panel glass
is located centrally in the roof panel opening.
4. Tighten the roof opening panel glass rear
retaining screws (left-hand side shown).
E49937
5. Adjust the front edge of the roof opening
panel glass.
1. Push the front edge up or down to give the
correct alignment (flush to -1 mm).
2. Tighten the front retaining screws (left-hand
side shown).
E49457
1
1
2
6. NOTE: An audible click can be heard when
the lower edge of the guide arm cover is
correctly located.
Starting at the front of the roof opening
panel, install the roof opening panel guide
arm covers (left-hand side shown).
1. Install the upper clip.
G323976en
501-17-
12
Roof Opening Panel
501-17-
12
GENERAL PROCEDURES
2. Install the lower clip.
TIE39806
1
2
7. Operate the roof opening panel and check
the alignment.
G323976en
501-17-
13
Roof Opening Panel
501-17-
13
GENERAL PROCEDURES
Roof Opening Panel Motor Initialization
Updating Roof Opening Panel Motor
Initialization
WARNING: The roof opening panel
anti-trap function will not operate during
the updating roof opening panel motor
initialization procedure. Make sure that the
roof opening panel opening is free of all
foreign material. Failure to follow this
instruction may result in personal injury.
NOTE: This procedure should only be carried out
when the roof opening panel motor has not been
disconnected.
NOTE: The roof opening panel alignment must be
carried out prior to carrying out roof opening panel
motor initialization.
For additional information,
refer to: Roof Opening
Panel Alignment
(501-17 Roof Opening Panel,
General Procedures).
1. Operate the roof opening panel control
switch to the up/close position until the roof
opening panel is in the fully vent position.
2. Release the roof opening panel control
switch.
3. Operate the roof opening panel control
switch to the up/close position and hold for
30 seconds until there is a small movement
(approximately 2 mm) and the roof opening
panel motor stops.
4. Release the roof opening panel control
switch.
5. NOTE: In one complete cycle the roof
opening panel will close, fully open and
return to the fully closed position.
Operate the roof opening panel control
switch to the up/close position again within
3 seconds until the roof opening panel stops
(one complete cycle).
Initial Roof Opening Panel Motor
Initialization
WARNING: The roof opening panel
anti-trap function will not operate during
the updating roof opening panel motor
initialization procedure. Make sure that the
roof opening panel opening is free of all
foreign material. Failure to follow this
instruction may result in personal injury.
NOTE: This procedure must be carried out when
installing any roof opening panel motor or roof
opening panel.
NOTE: The roof opening panel alignment must be
carried out prior to carrying out roof opening panel
motor initialization.
For additional information,
refer to: Roof Opening
Panel Alignment
(501-17 Roof Opening Panel,
General Procedures).
1. Operate the roof opening panel control
switch to the up/close position.
2. Release the roof opening panel control
switch.
3. NOTE: In one complete cycle the roof
opening panel will close, fully open and
return to the fully closed position.
Operate the roof opening panel control
switch to the up/close position again within
3 seconds until the roof opening panel stops
(one complete cycle).
Erasing Roof Opening Panel Motor
Initialization
NOTE: The erasing procedure is to be carried out
only when the roof opening panel motor has been
detached from the roof opening panel.
NOTE: This procedure must be carried out before
installing a previously used roof opening panel
motor.
1. Operate the roof opening panel control
switch to the up/close position until the roof
opening panel motor stops.
2. Release the roof opening panel control
switch.
3. Operate the roof opening panel control
switch again to the up/close position and
hold for 30 seconds. With the roof opening
panel control switch held, the roof opening
panel motor will rotate in one direction.
4. Release the roof opening panel control
switch.
5. Operate the roof opening panel control
switch to the down/open position. If the roof
opening panel motor does not rotate, the
erasing procedure has been carried out
successfully.
G323977en
501-17-
14
Roof Opening Panel
501-17-
14
GENERAL PROCEDURES
6. If the roof opening panel motor rotates (with
the roof opening panel control switch in the
down/open position), repeat the procedure.
G323977en
501-17-
15
Roof Opening Panel
501-17-
15
GENERAL PROCEDURES
Roof Opening Panel Glass
1. Move the roof opening panel shield
rearwards.
2. Remove the components in the order
indicated in the following illustration(s) and
table(s).
TIE39804
1
1
2
3
2
Description
Item
Roof opening panel guide arm covers
See Removal Detail
See Installation Detail
1
Roof opening panel glass retaining screws
See Installation Detail
2
Roof opening panel glass
3
3. To install, reverse the removal procedure.
Removal Details
Item 1
Roof opening panel guide arm covers
1. NOTE: Make sure the roof opening panel is
in the closed position.
Starting at the rear of the roof opening panel,
remove the roof opening panel guide arm
covers (left-hand side shown).
1. Release the lower clip.
G296325en
501-17-
16
Roof Opening Panel
501-17-
16
REMOVAL AND INSTALLATION
2. Release the upper clip.
TIE39805
1
2
Installation Details
Item 2
Roof opening panel glass retaining
screws
1. NOTE: Do not fully tighten the retaining
screws at this stage.
Install the roof opening panel glass retaining
screws on both sides (left-hand side shown).
E49936
2. Adjust the rear edge of the roof opening
panel glass.
• Push the rear edge up or down to give the
correct alignment (flush to + 1 mm).
E50044
3. Make sure that the roof opening panel glass
is located centrally in the roof panel opening.
4. Tighten the roof opening panel glass rear
retaining screws (left-hand side shown).
E49937
5. Adjust the front edge of the roof opening
panel glass.
1. Push the front edge up or down to give the
correct alignment (flush to -1 mm).
2. Tighten the front retaining screws (left-hand
side shown).
E49457
1
1
2
G296325en
501-17-
17
Roof Opening Panel
501-17-
17
REMOVAL AND INSTALLATION
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.
Текст