Dacia Solenza (engine E7J). Service manual — part 144
82
ACCOUSTIC WARNING - ANTI STARTING
82 - 33
Diagnostic
ALP7. UNLOCKING DOORS NOT OPERATING BY RF REMOTE CONTROL
RECOMMENDATION
Check the absence of failures with the CLIP tester.
If there are memorised failures, these must be repaired.
Are the states 11G and 11D becoming
ACTIVE when the RF remote control is
activated?
See the treatment of the states 11G
and 11D cf. chapter “Diagnostic”.
No
Check the fuse F03 condition from the cockpit
fuse box.
Is it good?
Replace the fuse.
No
Yes
Yes
See the treatment of the failure
“Doors blocking contact” and the
state 14 G cf. chapter
“Diagnostic”.
See ALP6.
Yes
No
AFTER REPAIRING
Perform a conformity checking.
Check the operation of the anti starting system.
Activate the doors’ locking switch from the
dashboard.
Are the doors blocking/ unlocking ?
82
ACCOUSTIC WARNING - ANTI STARTING
82 - 34
Diagnostic
ALP 8. TURNING LIGHTS DO NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS
RECOMMENDATION
Check the absence of the failures with the CLIP tester.
If there are failures, fix them first.
Check if the synchronisation of the RF remote control and the E.C.U. decoder has been
performed.
Are the turning lights functioning normally at the activation of the signalling switch ?
Check the continuity and the isolation
related to the mass and the +12 V of the
electric layout:
E.C.U. decoder FLASH relay
Pin B3 pole 2
Is it correct?
Repair the signalling system.
Check the fuse F03 and F04.
Fix the electric layout.
Check the fuse F02 condition from the cockpit
fuse box.
Is it good?
Replace the fuse.
Disconnect the FLASH relay. Supply with
+12, the pole 4 of the relay. Are the left turning
lights turning on? Supply with +12 V the pole
5 of the signal relay. Are the right/left turning
lights turning on?
Repair the electric layout from
poles 4 and 5 of the FLASH relay.
Replace the FLASH relay.
AFTER REPAIRING
Perform a conformity checking.
Check the operation of the anti starting system.
No
No
No
Yes
Yes
Yes
Yes
No
82
ACCOUSTIC WARNING - ANTI STARTING
82 - 35
Diagnostic
No
AFTER REPAIRING
Perform a conformity checking.
Check the operation of the anti starting system.
ALP9. THE CEILING LAMP DOES NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS OR IT REMAINS PERMANENTLY TURNED ON
RECOMMENDATION
Check the absence of failures with the CLIP tester.
If there are memorised failures, fix them first.
Check if the doors are locked?
The ceiling lamp was in
the position “permanently
lighting”?
Normal
operation.
Yes
Yes
Unlock the doors with the RF remote control.
The ceiling is in the position “ceiling delayed
lighting ”.
Has the ceiling lamp turned on?
Check the isolation of the wiring related
to the mass on the line pinA1.
decoder pin 3 ceiling lamp.
After 15 seconds, the ceiling lamp will
turn off.
Normal operation.
Was the E.C.U. decoder configured “With
ceiling delayed lamp”?
Configure the E.C.U. decoder with
the CLIP tester.
Check the continuity on the line
E.C.U. decoder pin A1 pin 3 ceiling
lamp.
Is the line good?
Repair .
Check the ceiling lamp bulb.
No
No
No
Yes
Yes
Yes
No
82
ACCOUSTIC WARNING - ANTI STARTING
82 - 36
Diagnostic
THE CONFORMITY CHECKING
Next, the checking of different states and configurations of the anti starting system is to be
performed.
RECOMMENDATION
In case of finding some failures at the diagnostic by means of
the CLIP tester, analyse them based on the diagnostic (ALP)
corresponding to the respective failure.
Crt.
Function
State/ configuration
Observations
Nr.
1. Conformity E.C.U decoder. Computer identification
Display of the E.C.U.
decoder item.
2. Remote control type
2G = remote control
IR = infrared
configuration
RF = radio frequency
3. Ceiling delayed lamp
Without ceiling delayed lamp or Validation on the blue button
with ceiling delayed lamp
on CLIP screen.
4. Key programming
3G = configuration key
With one or 2 keys.
programming
5. Configuration petrol/ diesel 3D = configuration coded diesel Without = for petrol engine
electric valve.
or diesel without electric
valve.
6. Forced starting protection
9D = forced protecting mode
ACTIVE = only after
validation on the blue button.
7. Anti starting state
10G = anti starting
ACTIVE = with the contact
taken off or after 10 seconds
from the contact taken off.
8. Key presence
8D = key present
ACTIVE at the setting on
the contact if there is a
coded key.
REMARK: the states 8D,
9D, 10 D must be ACTIVE
at a correct operation.
9. Code key receiving
9D = received key code
ACTIVE at the setting on
the contact if the key is
coded in a good format.
10. Correct key code
10D = right key code
ACTIVE at the setting on
the contact if the key is
coded in a good format and
has the correct code.
REMARK: after the analyse
of the states 8D, 9D, 10 D
the contact will be set on
when the LED indicator
blinks ( ACTIVE anti
starting).