Dacia SuperNova (engine E7J). Service manual — part 40

E7J-A-2/60 ENGINE

17

IGNITION AND INJECTION

17 - 70

DIAGNOSING-BREAKDOWN LOCALIZATION ALGORITHM

Check if the clapper body is not clogged.

Check if there are cases of lack of watertightness (noise)
on the power-brakes.

Connect the tester “CLIP” and do the test corresponding
to the check-up of the rotation signal.

Check if the spurs, the brake cylinders and the wheel ball-
rings are not seized-up.

Check the body of
the clapper

Check the power-brakes

Check the engine
flywheel

Check the running
train

Check the cooling
of the engine

Check if there is enough engine cooling.

Check the canister
draining valve

Disconnect the tube between the draining valve and the in-
take collector and strangle it up. If the disturbances disap-
pear, the cause was the draining valve.

Check the engine
compression

Connect the “CLIP TEHNIC” device to do this test in accor-
dance with the usual manner of work.

AFTER REPAIR

Erase the defects memorized. If there are no other problems,
erase the parameters memorized by the calculator.

A

19 - 1

19

COOLING - EXHAUST - FUEL TANK

QUANTITY AND QUALITY OF COOLING LIQUID

TYPE ENGINE

QUANTITY

(

L

) C

ALITATE

PECULIARITIES

E7J 6

Anti-freeze type D Protection up to -40

0

C

GLACEOL RX

THERMOSTAT

TYPE ENGINE

START OF OPENING

(0C) END OF OPENING

(0C)

DRIVE

(

MM

)

E7J

89

101

7,5

CHARACTERISTICS

19 - 02

FILLING AND DRAINING

The heating radiator does not have a tap.
The circulation of the cooling liquid is done continuosly within the heating radiator, which con-
tributes to the heating of the engine.

F

ILLING

The tightening of the emptying stopper is checked.
The draining screw placed on the tube between the engine and the air-conditioning radiator is
taken off.
The circuit is filled through the hole of the de-gassing pot.
The draining screw is fastened when the liquid flows in a continuous jet.
The engine is set into motion (2500 rot/min).
The level is adjusted for approx. 4 minutes.
The stopper of the de-gassing pot is closed.

D

RAINING

The engine is let to run for 10 minutes at 2500 rot/min until the motor-ventilator starts (i.e. the
time for the automatic de-gassing).
Check if thelevel of the liquid is close to “Max”.
Do not open the draining screw when the engine is running.
Fasten again the stopper of the de-gassing pot with the engine still hot.

FILLING AND DRAINING

19

COOLING - EXHAUST - FUEL TANK

1.

CHECKING WATERTIGHTNESS OF CIRCUIT

The MS 554-01 adapter is mounted instead of the valve of the de-gassing pot.
The MS 554-07 device is connected to the adapter.
The engine is heated, and then stopped.

the pump is used in order to put the circuit under pressure.

The pumping is stopped at a value 0.1 bar smaller than the tare value of the valve (1.2 bar).
The pressure must not go down; otherwise, the leak is looked for.
The junction of the device for cooling system decompression is progressively unscrewed,

then the apparatus is taken off and the valve of the de-gassing pot, equipped with a new fitting,
is mounted.

2.

CHECKING WATERTIGHTNESS OF CIRCUIT

The MS 554-06 device, then the pressure in the circuit is reestablished; this pressure must

become stable at the tare value of the valve with the control tolerance of +/-0.1 bar.

The tare value of the valve of the de-gassing pot: 1.2 bar.

19

COOLING - EXHAUST - FUEL TANK

CONTROL

19 - 03