Dacia SuperNova (engine E7J). Service manual — part 40
E7J-A-2/60 ENGINE
17
IGNITION AND INJECTION
17 - 70
DIAGNOSING-BREAKDOWN LOCALIZATION ALGORITHM
Check if the clapper body is not clogged.
Check if there are cases of lack of watertightness (noise)
on the power-brakes.
Connect the tester “CLIP” and do the test corresponding
to the check-up of the rotation signal.
Check if the spurs, the brake cylinders and the wheel ball-
rings are not seized-up.
Check the body of
the clapper
♦
Check the power-brakes
Check the engine
flywheel
Check the running
train
Check the cooling
of the engine
♦
♦
♦
Check if there is enough engine cooling.
♦
Check the canister
draining valve
Disconnect the tube between the draining valve and the in-
take collector and strangle it up. If the disturbances disap-
pear, the cause was the draining valve.
Check the engine
compression
Connect the “CLIP TEHNIC” device to do this test in accor-
dance with the usual manner of work.
AFTER REPAIR
Erase the defects memorized. If there are no other problems,
erase the parameters memorized by the calculator.
♦
♦
A
19 - 1
19
COOLING - EXHAUST - FUEL TANK
QUANTITY AND QUALITY OF COOLING LIQUID
TYPE ENGINE
QUANTITY
(
L
) C
ALITATE
PECULIARITIES
E7J 6
Anti-freeze type D Protection up to -40
0
C
GLACEOL RX
THERMOSTAT
TYPE ENGINE
START OF OPENING
(0C) END OF OPENING
(0C)
DRIVE
(
MM
)
E7J
89
101
7,5
CHARACTERISTICS
19 - 02
FILLING AND DRAINING
The heating radiator does not have a tap.
The circulation of the cooling liquid is done continuosly within the heating radiator, which con-
tributes to the heating of the engine.
F
ILLING
The tightening of the emptying stopper is checked.
The draining screw placed on the tube between the engine and the air-conditioning radiator is
taken off.
The circuit is filled through the hole of the de-gassing pot.
The draining screw is fastened when the liquid flows in a continuous jet.
The engine is set into motion (2500 rot/min).
The level is adjusted for approx. 4 minutes.
The stopper of the de-gassing pot is closed.
D
RAINING
The engine is let to run for 10 minutes at 2500 rot/min until the motor-ventilator starts (i.e. the
time for the automatic de-gassing).
Check if thelevel of the liquid is close to “Max”.
Do not open the draining screw when the engine is running.
Fasten again the stopper of the de-gassing pot with the engine still hot.
FILLING AND DRAINING
19
COOLING - EXHAUST - FUEL TANK
1.
CHECKING WATERTIGHTNESS OF CIRCUIT
The MS 554-01 adapter is mounted instead of the valve of the de-gassing pot.
The MS 554-07 device is connected to the adapter.
The engine is heated, and then stopped.
the pump is used in order to put the circuit under pressure.
The pumping is stopped at a value 0.1 bar smaller than the tare value of the valve (1.2 bar).
The pressure must not go down; otherwise, the leak is looked for.
The junction of the device for cooling system decompression is progressively unscrewed,
then the apparatus is taken off and the valve of the de-gassing pot, equipped with a new fitting,
is mounted.
2.
CHECKING WATERTIGHTNESS OF CIRCUIT
The MS 554-06 device, then the pressure in the circuit is reestablished; this pressure must
become stable at the tare value of the valve with the control tolerance of +/-0.1 bar.
The tare value of the valve of the de-gassing pot: 1.2 bar.
19
COOLING - EXHAUST - FUEL TANK
CONTROL
19 - 03