SsangYong Rodius (2013 year). Service manual — part 74
10-8
(2) Pre-heating time control based on battery voltage
GCU monitors the battery voltage. If it is low, GCU extends the pre-heating time.
GCU monitors the energy to glow plugs (the amount of pre-heating energy is always same).
-
-
GCU monitors the battery voltage. If it is low, GCU extends the pre-heating time to get enough
energy.
-
GCU monitors the battery voltage. If it is low, GCU increases PWM duty..
-
10-9
1413-00
(3) Power control
GCU PWM control
This describes the voltage supplying types to glow plugs.
-
GCU estimates the temperature of glow plug for pre-heating. To avoid the power loss and overheat,
GCU supplies the lowest power for getting target temperature when turning ON the ignition from
OFF.
-
(4) Operation
Frequency: 20~33Hz
PWM control duty ratio
- 1st step: 100%
- 2~3 step: 35%
- 4th step: 23%
10-10
(5) Pre-glow and Post-glow
This shows the pre-glow and post-glow step as a chart.
11-3
1461-01
1. SPECIFICATION
Description
Specification
Capacity
12V 2.3kW
Engagement
Meshed type
Rotating direction
Clockwise
Pinion gear manufacturing
Cooled forging
Solenoid operating voltage
Max. 8 V
Weight
2.5 kg
Bracket manufacturing
Aluminum die casting