Hyundai Santa Fe (2006 year). Manual — part 154
ETACS (ELECTRONIC TIME AND ALARM CONTROL SYSTEM)
BE -77
11. KEY OPERATED WARNING
1)
In state of KEY IN SW is IN, if the DRIVER DOOR
is opened, then the CHIME BUZZER output shall
be continued with the cycle of 0.7 seconds.
2)
If KEY IN SW is OUT or the driver’s door is closed
during the Chime Buzzer output, then the output
shall be OFF.
ON
OFF
KEY IN
SW
DRIVER
DOOR SW
CHIME
BUZZER
IN
OUT
OPEN
CLOSE
T1
SCMBE6163L
T1 : 0.7 ± sec.
12. OVER SPEED WARNING
In the IGN 2 ON state, if the over speed SW of the
cluster is On, the chime buzzer output shall be ON.
If the over speed SW is OFF, the chime buzzer output
shall be OFF.
OVER
SPEED
SW
ON
OFF
CHIME
BUZZER
ON
OFF
IGN 2
ON
OFF
T1 T1
SCMBE6904L
T1 : 0.5 ± 0.1 sec.
13. PARKING START WARNING
In the state that the IGN1 is ON or the Parking Brake
is pulled, if the speed of vehicle is maintained over 10
km/h for 2~3 seconds or more, then the Chime Buzzer
output shall be continued with 1 second cycle of the
ON/OFF (0.3/0.7 seconds). But, after the speed of
vehicle is maintained over 10 km/h for 2~3 seconds
or more, if the Parking Brake is pulled, output imme-
diately.
ON
OFF
ON
OFF
ON
OFF
T2
T1
T3
IGN1
P/BRAKE
SW
VEHICLE
SPEED
CHIME
BUZZER
OVER
10KPH
UNDER
10KPH
SCMBE6164L
T1 : 2.5±0.5 sec, T2 : 0.3±0.1 sec,
T3 : 0.7±0.1 sec.
BE -78
BODY ELECTRICAL SYSTEM
14. IGN KEY HOLE ILLUMINATION
1)
If the driver’s door (or assist’ s door) is opened
in the state that the IGN1 SW is OFF, then the
IGN Key Hole Illumination shall be ON.
2)
In the (1) state, if the driver’s door (or assist’s
door) is closed, then the IGN Key Hole Illumina-
tion shall be OFF after it is in the ON state for 30
seconds.
3)
During the (1) and (2) operating, if the IGN1 SW
is On, the IGN Key Hole Illumination shall be OFF
immediately.
4)
But, if it is in the ARM Mode, then the IGN Key
Hole Illumination shall be OFF immediately.
ON
OFF
ON
OFF
OPEN
CLOSE
IGN1
DRIVER
or ASSIST
DOOR SW
KEY ILL.
LAMP
T1
T1
T1
SCMBE6165L
T1 : 30 ± 1 sec.
15. DEFOGGER TIMER
1)
If the Defogger SW is ON after the ALT "L" is ON
in the state that the IGN1 SW is ON, then the De-
fogger output shall be ON for 20 minutes. (Oper-
ating in the state of the ENGINE RUNNING)
2)
If the DEFOGGER SW is ON again while the DE-
FOGGER output is ON, then the DEFOGGER
output shall be OFF.
3)
If the ALT "L" is OFF or IGN1 is OFF while the
DEFOGGER output is ON, then the DEFOGGER
output shall be OFF.
4)
If the ALT "L" > 10 volts, then it shall be in the
Engine Running State (ALT "L" shall be ON); if
the ALT "L" < 5 volts, then it shall be in the En-
gine Stop State (ALT "L" shall be OFF). Also, if
the ALT "L" is more than 5 and less than 10 volts,
then the former state shall be maintained.
5)
If the defogger SW is pressed and the ALT "L"
is ON, there shall be no the DEFOGGER RLY
output.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
IGN1
ATL 'L'
DEICER
SW
DEICER
RELAY
T1
T1
T1
T2
T2
T2
SCMBE6166L
T1 : 60 ± 20 msec, T2 : 20 ± 1 min.
ETACS (ELECTRONIC TIME AND ALARM CONTROL SYSTEM)
BE -79
16. DECAYED ROOM LAMP & KEYLESS UNLOCK
TIMER
CONDITION 1
State
Description
Initial Condition
Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE
Transition Condition
In the state that all doors are closed, the 4DOOR or T/GATE is opened over 0.1 seconds.
Operating
-
Entry into the ROOM LAMP ON state for 20 min
-
ROOM LAMP ON for 20 ± 1 min
CONDITION 2
State
Description
Initial Condition
Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE
Transition Condition
In case of UNLOCK by the TX
Operating
-
Entry into the ROOM LAMP ON state for 30s
-
ROOM LAMP ON for 30 ± 3seconds
CONDITION 3
State
Description
Initial Condition
Room lamp OFF & IGN1 OFF & 4DOOR AND T/GATE CLOSE
Transition Condition
IGN1 ON and 4 DOOR or T/GATE OPEN over 0.1 seconds
Operating
-
Entry into the ROOM LAMP ON state
-
ROOM LAMP ON
ON
OFF
ON
OFF
ON
OFF
OPEN
CLOSE
IGN1
T1
T2
T3
DOOR
UNLOCK
ROOM
LAMP
SCMBE6167L
T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
BE -80
BODY ELECTRICAL SYSTEM
CONDITION 4
State
Description
Initial Condition
ROOM LAMP ON for 30s & IGN1 OFF
Transition Condition
In the state that all doors are closed, the 4DOOR or T/GATE is opened over 0.1 seconds.
Operating
-
Entry into the ROOM LAMP ON state for 20 min
-
ROOM LAMP ON for 20 ± 1min.
CONDITION 5
State
Description
Initial Condition
ROOM LAMP ON for 30s & IGN1 OFF
Transition Condition
In case of UNLOCK by the TX.
Operating
-
Maintain in the ROOM LAMP ON state for 30s
-
Extend the ROOM LAMP ON state for 30 seconds.
CONDITION 6
State
Description
Initial Condition
ROOM LAMP ON for 30s & IGN1 OFF
Transition Condition
IGN1 ON, or after 30 seconds, or when entered into the ARM state,
or when all doors are locked.
Operating
-
Entry into the ROOM LAMP DECAYING state
-
After the ROOM LAMP is decayed for 2 ± 0.2 seconds, it shall be OFF.
DOOR
OPEN
CLOSE
IGN 1
ON
OFF
UNLOCK
ON
OFF
ROOM
LAMP
ON
OFF
T2
T1
All DOOR
LOCK
SW
LOCK
UNLOCK
T2
T2
T2
T3
T2
SCMBE6905L
T1 : 20 ± 1 min, T2 : 30 ± 3 sec,
T3 : 100 ms.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.