Hyundai Tiburon (2003 year). Manual — part 145
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Blower > Blower Unit >
Repair procedures, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning >
Blower > Blower Unit > Repair procedures
REMOVAL
1. Disconnect the negative cable from the battery.
2. Remove the crash pad (see BD group - crash pad).
3. Disconnect the connectors(A) from the blower relay the blower motor, the blower resistor (or power transistor)
and the fresh and recirculation actuator.
Remove the self-tapping screws(B), the mounting nut(C), the mounting bolts(D) and the blower unit(E).
Make sure that there is no air leaking out of the blower and duct joints.
AIR FILTER REPLACEMENT
1. Remove the mounting screws on the downside of the glove box.
2. Open the glove box and remove the mounting screws on the upside of the glove box.
3. Remove the filter cover.
4. Replace the air filter with a new one.
5. Installation is the reverse of the removal.
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Blower > Blower Motor
> Schematic Diagrams, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning >
Blower > Blower Motor > Schematic Diagrams
CONNECTOR
Moter : Magnet ø70
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Blower > Blower Motor
> Description and Operation, TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air
Conditioning > Blower > Blower Motor > Description and Operation
DESCRIPTION
Item
Speccifications
Type
DC ferrite
20°C or 68°F
Rated voltage
DC 12 volts
No load speed
Min. 3300rpm
No load current
Max. 3.0A
Rated load
5.0kgf·cm
Speed in rated load
2900 ± 250rpm
Current in rated load
Continuous
Insulation resistance
Min. 1M
Ω
Rotation direction viewed from output (Mtr.
shaft)
CCW
Operation temp. range
-30° ~ +80°