Hyundai Tiburon (2003 year). Manual — part 137
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Air conditioning System >
Refrigerant line > Components and Components Location, TIBURON(GK) > 2003 > G 2.7 V6 DOHC >
Heating,Ventilation, Air Conditioning > Air conditioning System > Refrigerant line > Components and
Components Location
COMPONENT LOCATION
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Air conditioning
System > Triple pressure switch > Schematic Diagrams, TIBURON(GK) > 2003 > G 2.7 V6 DOHC >
Heating,Ventilation, Air Conditioning > Air conditioning System > Triple pressure switch > Schematic
Diagrams
CONNECTOR
CIRCUIT DIAGRAM
TIBURON(GK) > 2003 > G 2.7 V6 DOHC > Heating,Ventilation, Air Conditioning > Air conditioning
System > Triple pressure switch > Description and Operation, TIBURON(GK) > 2003 > G 2.7 V6 DOHC >
Heating,Ventilation, Air Conditioning > Air conditioning System > Triple pressure switch > Description
and Operation
DESCRIPTION
- Rating load : Inductive loacl DC 12V, 10~250mA
- Applicable voltage range : DC 8V ~ DC 16V
- Applicable temperature range : -30°C ~ 120°C
- Applicable refrigerant : R-134a
- Insulation resistance : Min. 100M
Ω
at DC 500V
Pressure
ON
OFF
High
32.0 ± 2.0
26.0 ± 2.0
Low
2.3 + 0.25 / -0.29
2.0 ± 0.2
Medium
18.0 ± 0.8
14.0 ± 1.2
LOW & HIGH
MEDIUM
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.