SsangYong Korando II (1996-2006 year). Manual — part 389
MANUAL & SEMIAUTO-HVAC 7C-25
SSANGYONG MY2002
KAA7C300
KAA7C310
Removel & Installation Procedure
1. Remove the switch panel.
Notice: Be careful not to damage the switch panel.
2. Remove the fixing screws (4 screws) of the control
box.
3. Disconnect the wire connectors and remove the
control box.
4. Installation is reverse order of the removal.
KAA7D130
KAA7D140
AIR FILTER
Removal and Installation Procedures
Notice: Replace earlier if air pollution is heavy.
1. Open the glove box and pull it inward to release
the upper left and right locking portion.
Notice: Remove the glove box by unscrewing
lower 2 screws, if necessary.
2. Press the 2 filter cover holds and remove the air
filter cover.
3. Remove the 2 air filters.
Notice: For installation, remember the installed
direction of the air filter before removal.
Replacement Interval
Every 10,000 km
SECTION 7D
FULL AUTOMATIC TEMPERATURE
CONTROL HEATING, VENTILATION AND
AIR CONDITIONING SYSTEM
FATC (Full Automatic Temperature Control) is full automatic heater and airconditioning system that detects
incar temperature, ambient temperature, sun load and coolant temperature and controls airconditioner
system blowing capacity, outlet temperature and intaking/outlet mode to maintain interior comfort.
TABLE OF CONTENTS
Specifications . . . . . . . . . . . . . ... 7D-2
Refrigerant . . . . . . . . . . . . . . .. 7D-2
Evaporator Unit . . . . . . . . . . . . . 7D-2
Blower Unit . . . . . . . . . . . . . . .. 7D-2
Compressor . . . . . . . . . . . . . . . 7D-2
Condenser . . . . . . . . . . . . . . ... 7D-2
Receiver Drier . . . . . . . . . . . . . .. 7D-2
Pressure Switch . . . . . . . . . . . . ... 7D-3
Air Filter . . . . . . . . . . . . . . . ... 7D-3
Heater Unit . . . . . . . . . . . . . . .. 7D-3
Service Specifications . . . . . . . . . . .. 7D-4
Fastener Tightening Specifications . . . . . ... 7D-4
Schematic and Routing Diagrams . . . . . ... 7D-5
Circuit Diagram . . . . . . . . . . . . . 7D-5
FATC Block Diagram . . . . . . . . . . ... 7D-6
Component Locator . . . . . . . . . . . . 7D-7
Ventilation System . . . . . . . . . . . ... 7D-7
Function Description . . . . . . . . . . . 7D-8
Diagnosis . . . . . . . . . . . . . . . .. 7D-9
Diagnosis Test . . . . . . . . . . . . . . 7D-9
Maintenance and Repair . . . . . . . . ... 7D-13
FATC Control Panel . . . . . . . . . . . 7D-13
Air Filter . . . . . . . . . . . . . . . . 7D-16
Troubleshooting . . . . . . . . . . . . . 7D-17
SSANGYONG MY2002
7D-2 FATC-HAVC
SPECIFICATIONS
REFRIGERANT
Core Size (LxWxT)
Core Type
Expansion Valve Type
Thermostat
Resister Type
Cooling Capacity
Application
Description
237.0 x 232.0 x 92.0
Aluminum plate
Angle
ON:4.5 ± 0.6°C, OFF:1.5 ± 0.6°C
Aluminum plate
4,300 Kcal/h (AT 420 CMH)
Capacity
Type
Application
Description
650 - 750 g
R134a
EVAPORATOR UNIT
BLOWER UNIT
Motor Type
Motor Size
Application
Description
Magnetic
φ
70 x 145
COMPRESSOR
Model
Type
Displacement (cc/rev.)
PCD (Pulley Center Diameter)
Oil
Magnetic clutch output
Application
Description
FK-II (DKV 14C)
Vane rotary type
140.5 (cc/rev)
φ
143
ZXL 200 PG (PAG Oil)
45 W
CONDENSER
Size (WxHxT)
Capacity
Type
Application
Description
650 x 339.2 x 22.0
11,000 Kcal/h
Parallel Flow
RECEIVER DRIER
Material
Capacity
Desiccant
Application
Description
Aluminum
250 cc
XH-9 (35 g)
FATC-HAVC 7D-3
SSANGYONG MY2002
PRESSURE SWITCH
Type
High (OFF)
Low (ON)
Application
Description
Direct
OFF : 32 ± 2 Kgf/cm
2
, DIFF : 6 ± 2 Kgf/cm
2
OFF : 2.0 ± 0.2 Kgf/cm
2
, ON : 2.1 ± 0.2 Kgf/cm
2
AIR FILTER
Replacement
Application
Description
Every 12,000 km (replace earlier if air pollution is heavy)
HEATER UNIT
Heater Core Type
Heating Capacity
Heater Core Size (L x W x T)
Application
Description
2-ROW
4,600 Kcal/h (AT 300 CMH)
219.5 x 151.8 x 52