SSANGYONG MY2002
7D-4 FATC-HAVC
SERVICE SPECIFICATIONS
Input Section
Incar Sensor
Ambient Sensor
Coolant Temperature Sensor
Application
Description
Resistance (25°C)
Voltage Rating
Current Rating
Resistance (25°C)
Voltage Rating
Current Rating
Resistance (25°C)
Voltage Rating
Current Rating
Evaporator Unit
2.186 k
Ω
± 0.07 k
Ω
5 V
3 mA
1.0 k
Ω
± 0.03 k
Ω
5 V
3 mA
0.55 k
Ω
± 0.02 k
Ω
5 V
3 mA
Intake Actuator
Mode Actuator
Mix Actuator
Power TR
Blower Motor Power Consumption
Application
Description
Current Rating (at 12 V)
LOCK Current
Current Rating (at 12 V)
LOCK Current
Current Rating (at 12 V)
LOCK Current
Ic
Pc
70 ± 30 mA
Less than 500 mA
100 ± 40 mA
Less than 500 mA
100 ± 40 mA
Less than 500 mA
30 A
200 W
220 W
FASTENER TIGHTENING SPECIFICATIONS
N • m
4 - 6
4 - 6
4 - 6
5 - 8
4 - 6
20 - 30
20 - 26
Lb-Ft
2.9 - 4.4
2.9 - 4.4
2.9 - 4.4
3.7 - 5.9
2.9 - 4.4
14.7 - 22.1
14.7 - 19.1
Condenser Bolt
Condenser Fan Nut
Condenser Bolt
Receiver Drier Pipe Bolt
Receiver Drier Pipe Bolt (Condenser)
Pressure Pipe Bolt
Pressure Mounting Bolt
Lb-In
35.4 - 53.1
35.4 - 53.1
35.4 - 53.1
44.2 - 70.8
35.4 - 53.1
177.0 - 265.5
177.0 - 230.1
Application
FATC-HAVC 7D-5
SSANGYONG MY2002
SCHEMATIC AND ROUTING DIAGRAMS
CIRCUIT DIAGRAM
KAA7D010
SSANGYONG MY2002
7D-6 FATC-HAVC
FATC BLOCK DIAGRAM
INCAR SENSOR
AMBIENT SENSOR
WATER TEMPERATURE SENSOR
SUN LOAD SENSOR
TEMPERATURE SWITCH
BLOWER SWITCH
MODE SWITCH
DEFROSTER SWITCH
INTAKE SWITCH
AUTO SWITCH
A/CON SWITCH
OFF SWITCH
TEMP DOOR POSITION FEEDBACK
VOLTAGE
POWER TRANSISTOR COLLECTOR
VOLTAGE
VFD
MAX HI RELAY
POWER T/R
BLOWER
MOTOR
ECU
COMPRESSOR
MIX ACTUATOR
MIX DOOR
INTAKE ACTUATOR
INTAKE DOOR
MODE ACTUATOR
MODE DOOR
Airconditioner output
C
O
N
T
R
O
L
U
N
I
T
FATC-HAVC 7D-7
SSANGYONG MY2002
KAA7D020
COMPONENT LOCATOR
VENTILATION SYSTEM