SsangYong Musso. Manual — part 34
9T-6 REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM
Input Memory
!
When the REKES transmitter is lost
1. Connect the battery terminal No.3 and REKES terminal No.4
which are on the diagnosis socket in engine room with service
lead wire.
2. Push the lock or unlock button on the REKES transmitter.
3. Input Memory and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
!
When the transmitter is faulty
1. Replace the REKES transmitter with a new one and connect
the wiring connector.
2. Set the input switch of the REKES receiver onto the No.1 or
No.2 position and push the lock or unlock button on the
REKES transmitter.
3. Set the input switch of the REKES receiver onto the central
position and close all doors.
4. Check the operation of door locking system by pushing the
lock or unlock button on the REKES transmitter.
1
REKES Transmitter
2
Input Switch of the REKES Receive
3
REKES Switch
REMOTE KEYLESS ENTRY AND ANTI-THEFT SYSTEM 9T-7
Characteristic Signal
1. Lock or unlock all doors according to the REKES signal
when the key is removed from the key hole.
2. Characteristic Signal : Right Picture
3. Time Interval
T1 : 0.05 ± 0.02sec.(lock signal)
T2 : 0.1 ± 0.02sec.(unlock signal)
T3 : within 0.25sec.
T4 : 0.5 ± 0.1sec.
T5 : within 0.35sec.
T6,T7 : 0.5 ± 0.1sec.
T8 : 1 ± 0.25sec.
Connector Appearance and Connecting Circuit
Pin No.
1
2
3
4
5
6
Connecting Circuit
B+
Memory Terminal
Key Reminder Switch
STICS
Ground
Memory Terminal
SECTION 9U
CONTROL UNITS AND SYSTEM
Caution: Disconnect the negative battery cable before removing or installing any electrical unit or when a
tool or equipment could easily come in contact with exposed electrical terminals. Disconnecting this cable
will help prevent personal injury and damage to the vehicle. The ignition must also be in LOCK unless otherwise
noted.
TABLE OF CONTENTS
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 9U-1
STICS Specifications . . . . . . . . . . . . . . . . . . . 9U-1
Schematic and Routing Diagrams . . . . . . . . 9U-2
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-2
Function Description . . . . . . . . . . . . . . . . . . 9U-3
SPECIFICATIONS
STICS SPECIFICATIONS
Description
DC 12V
Dc 9V - 16V
Less than 1mA(key is removed and all doors locked)
-30
°
C - +80
°
C
Between terminal No.5 and 3,4,8,12,18,25
Between terminal No. 5 and 2,6,7,16,17
Between terminal No.5 and 11, 27
Application
Voltage Rating
Voltage Rating
Current Consumption
Operating Temperature
Voltage Drop
(at DC 12V)
Max. 1.2V
Max. 1.8V
Max. 2.0V
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-3
Maintenance and Repair . . . . . . . . . . . . . . 9U-10
On-Vehicle Service . . . . . . . . . . . . . . . . . . . . . 9U-10
STICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9U-10
9U-2 CONTROL UNITS AND SYSTEM
STICS
SCHEMATIC AND ROUTING DIAGRAMS
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.