SsangYong Stavic / SsangYong Rodius (2005 year). Manual — part 39
1D-20
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ENGINE MECHANICAL
M162 GSL ENG SM - 2005.7
1. Deaeration hose
2. Radiator
3. Inlet hose
4. Bolt
RADIATOR
Preceding Work: Removal of cooling fan shroud
5. Lower radiator insulator
6. Plate
7. Clip
8. Upper radiator insulator
1D-21
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ENGINE MECHANICAL
M162 GSL ENG SM - 2005.7
Removal & Installation Procedure
1. Drain coolant from the radiator.
2. Remove the each coolant hoses.
3. Remove the upper and lower automatic transmission oil
cooling pipes from radiator.
Installation
4. Remove the mounting bolt (9) from the automatic
transmission oil cooler pipe (5) and then disconnect the
cooler pipe (5).
Installation
7. Remove the front and upper member mounting bolts and
front end upper member.
Installation
8. Remove the radiator
9. Check the radiator pin for crack, damage, leakage and
bending and replace it if necessary.
10. Installation should follow the removal procedure in the
reverse order.
11. Check for leakage in the cooling system.
Tightening torque
25 ~ 35 Nm
(18 ~ 26 lb-ft)
5. Remove the cooling fan shroud bolts and cooling fan
shroud.
Installation
6. Remove the radiator grille mounting screw and radiator
grille.
Tightening torque
3 ~ 7 Nm
(27 ~ 62 lb-in)
Tightening torque
3 ~ 7 Nm
(27 ~ 62 lb-in)
Tightening torque
30 ~ 40 Nm
(22 ~ 30 lb-ft)
1D-22
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ENGINE MECHANICAL
M162 GSL ENG SM - 2005.7
Cooling system
Coolant
Thermostat
Cooling fan
Coolant reservoir
Water pump
Radiator
Coolant temperature
gauge
Engine coolant
temperature sensor
Anti-freeze agent
GENERAL SPECIFICATIONS
SPECIFICATION
Water cooling forced
circulation
11.3
Wax pellet type
82 (180)
95 (203)
80 (176)
7
Electric cooling
5
320
95 (203)
90 (194)
105 (221)
100 (212)
269.8 (1860)
118 ~ 147 (17.1 ~ 21.3)
9.8 (1.4)
Turbo centrifugal
65
8
Cross-flow
701
372
18
45,000
185.2
47.4
28.2
3.33 ~ 37.8
0.32 ~ 0.35
ALUTEC-P78
50 : 50
-
L
-
°C (°F)
°C (°F)
°C (°F)
mm
-
-
mm
°C (°F)
°C (°F)
°C (°F)
°C (°F)
kPa (psi)
kPa (psi)
kPa (psi)
-
mm
-
-
mm
mm
mm
Kcal/h
Ω
Ω
Ω
K
Ω
K
Ω
-
-
Type
Capacity
Type
Initial opening temp.
Fully opening temp.
Fully closing temp.
Stroke
Type
Blades
Diameter
Low speed ON temp.
Low speed OFF temp.
High speed ON temp.
High speed OFF temp.
High speed ON temp. (By A/C pressure)
Pressure valve opening pressure
Vacuum valve opening pressure
Type
Impeller diameter
Impeller blades
Type
Core width
Core height
Core thickness
Minimum radiation capability
Resistance (at 50°C (122°F))
Resistance (at 80°C (176°F))
Resistance (at 105°C (221°F))
Resistance (at 20°C (68°F))
Resistance (at 80°C (176°F))
Type
Mixture of water and good quality ethylene
glycol-base anti-freeze
Application
Gasoline Engine
Unit
1D-23
CHANGED BY
EFFECTIVE DATE
AFFECTED VIN
ENGINE MECHANICAL
M162 GSL ENG SM - 2005.7
FASTENER TIGHTENING SPECIFICATIONS
Application
Automatic transmission oil cooler pipe
Automatic transmission oil cooler pipe mounting bolt
Coolant drain plug
Cooling fan bolt
Cooling fan shroud bolt
Engine hanger bracket and coolant outlet port bolt
Radiator mounting bracket bolt
Thermostat cover bracket bolt
Viscous clutch mounting bolt
Water pump mounting bolt
Nm
20
3 ~ 7
30
9 ~ 11
3 ~ 7
22.5 ~ 27.5
3 ~ 7
9 ~ 11
40.5 ~ 49.5
22.5 ~ 27.5
Lb-Ft
15
-
22
-
-
16.6 ~ 20.3
-
-
29.8 ~ 36.5
16.6 ~ 20.3
Lb-In
-
27 ~ 62
-
80 ~ 97
27 ~ 62
-
27 ~ 62
80 ~ 97
-
-