Isuzu D-Max / Isuzu Rodeo (TFR/TFS). Manual — part 600

ENGINE ELECTRICAL 6D – 7

SYMBOLS AND ABBREVIATIONS

DESCRIPTION

The symbols and abbreviations used in the circuit diagram
make the diagram easier to read and understand.

SYMBOLS

The illustration at the left shows a typical symbol



used

in circuit diagrams.
Refer to the following table.

SYMBOL AND MEANING

Symbol Meaning Symbol Meaning

Fuse

Single filament bulb

Main fuse

Double filament bulb

Fusible link wire

Motor

Switch

Variable resistor

Switch

Coil (Inductor)

6D – 8 ENGINE ELECTRICAL

Symbol Meaning Symbol Meaning

Contact wiring

Battery

Relay

Note:
Relay contact shown in the
wiring diagram indicates
condition before actuation.

Diode

Connector

Electronic part

Light emitting diode

Resistor

Reed switch

Speaker

Condenser

ABBREVIATIONS

The illustration at the left shows a typical abbreviation



used in circuit diagrams.
These same abbreviations may also appear in the next.
Refer to the following table.

ABBREVIATION AND MEANING

Abbreviation Meaning Abbreviation Meaning

RH

LH

SW

M/T

A/T

FT

RR

FLW

TEMP

ECM

Right-hand side
Left-hand side
Switch
Manual transmission
Automatic transmission
Front
Rear
Fusible link wire
Temperature
Electronic control module

STD

OPT

W/

WO/

OD

ACC

A/C

ATF

VSV

Standard equipment
Optional equipment
With
Without
Overdrive
Accessories
Air conditioner
Automatic transmission fluid
Vacuum switching valve

ENGINE ELECTRICAL 6D – 9

TORQUE SPECIFICATIONS

GENERATOR

kg

m(ft. lbs/N m)






















STARTER MOTOR

kg

m(ft. lbs/N m)

0.65

±±±± 0.5(4.7 ±±±± 3.6/6.3 ±±±± 4.9)

6D – 10 ENGINE ELECTRICAL

GENERATOR

REMOVAL AND INSTALLATION

Read this Section carefully before performing any removal and installation procedure. This Section gives you
important points as well as the order of operation. Be sure that you understand everything in this Section before you
begin.















































Important Operations-Removal

Cooling Fan Belt

1) Disconnect the battery cables at the battery terminals.
2) Loosen and remove the fan belt adjusting plate bolts.
3) Remove the fan belt from the generator drive pulley.


Generator

Remove the generator bolt and the generator from the
bracket.


Important Operations-Installation

Follow the removal procedure in the reverse order to
perform the installation procedure. Pay careful attention to
the important points during the installation procedure.


Generator

1) Install the generator to the bracket.
2) Tighten the generator bolt to the specified torque.

Generator Bolt Torque

kg·m (lb·ft/N·m)



1.9

± 0.5 (13.7 ± 3.6/18.6 ± 4.9)

‚

4.1

± 0.6 (29.6 ± 4.3/40.2 ± 5.9)

066L200001