DIAGNOSIS 7A2-59
Gear Position & Shift Solenoid Operation
Range
TCM terminal
Gear
B8
(High clutch
solenoid)
B9
(Low clutch
solenoid)
B7
(2-4 brake
solenoid)
B6
(Low & reverse
brake solenoid)
P
×
R Reverse
×
×
N
×
D, 3, 2
1st
×
2nd
×
×
3rd
×
×
4th
×
×
L 1st
×
×
2nd
×
×
3rd
×
×
4th
×
×
: On (Operated)
×
: Off (Not operated)
Setting Condition:
•
The low clutch duty solenoid signal is open circuit or short circuit.
(The voltage different from the output ON/OFF signals was detected while the TCM monitors the solenoid output
voltage.)
Fail Safe:
•
When the vehicle is running, the operation of the low clutch duty solenoid and the lock-up solenoid is stopped
(OFF), the gear position selected at the trouble detection is held, and the lock-up is inhibited.
•
After the vehicle stopped, all solenoid operations stop (OFF) and the gear is fixed to the 3rd.
Possible Cause:
•
Low clutch duty solenoid malfunction.
•
Open (Off) circuit or short (On) circuit harness of the low clutch duty solenoid.
•
Open circuit, short circuit to battery or short circuit to ground between low clutch duty solenoid terminal 3 and
TCM terminal B9 (C95).
•
Insufficient ground condition of the low clutch duty solenoid.
•
Poor connection of each connector.
7A2-60 DIAGNOSIS
Reference:
When the low clutch duty solenoid is operated, following signal is outputs.
Measurement terminal: B9 (C95) and B22 (C95)
-AC range by circuit tester: Approximately 6.8V
Low Clutch Duty Solenoid Reference Wave Form
Measurement Terminal: B9 (+)
B22 (-)
Measurement Scale: 5V/div
20ms/div
Measurement Condition: D range 4th gear
Measurement Terminal: B9 (+)
B22 (-)
Measurement Scale: 5V/div
20ms/div
Measurement Condition: P, N range in idle
DIAGNOSIS 7A2-61
DTC P0748 (Flash Code 35) Line Pressure Solenoid Failure
Control Valve
TCM
B17
B23
BLK
Lock-up Solenoid
Terminal
Assembly
VIO
Line Pressure Solenoid
E54
(4)
(6)
H23
(14)
(6)
C95
(17)
(23)
BLK
VIO
Setting Condition:
•
The line pressure solenoid signal is open circuit or short circuit.
(The voltage different from the output ON/OFF signals was detected while the TCM monitors the solenoid output
voltage.)
Fail Safe:
•
The operation of the line pressure solenoid is stopped (OFF).
Possible Cause:
•
Line pressure solenoid malfunction.
•
Line pressure solenoid harness open (Off) circuit or short (On) circuit.
7A2-62 DIAGNOSIS
•
Open circuit, short circuit to battery or short circuit to ground between line pressure solenoid terminal 6 and TCM
terminal B23 (C95).
•
Insufficient ground condition of the line pressure solenoid.
•
Poor connection of each connector.
Reference:
When the line pressure solenoid is operated, following signal is outputted.
Measurement terminal: B23 (C95) and B22 (C95)
-At N rage: Battery voltage
-At D range: Less than 1V