8A-346 ELECTRICAL-BODY AND CHASSIS
TEMPERATURE GAUGE AND THERMO UNIT (4JA1T(L), 4JH1-TC, C24SE)
1. No temperature indicates at all
Checkpoint
Trouble
Cause
Countermeasure
Replace the thermo unit
Thermo unit malfunction
NG
Replace the case baseboard
assy
Gauge function
1. Disconnect the unit
connector then connect
3.4W bulb to wire harness
side with ground
2. Check indicating point
when starter SW. is ON
position (Temperature
should indicate)
Gauge malfunction
Repair open circuit or
connector contact
Continuity between 1
E19
(C24SE : 1
E65
) and 16
B23
(C24SE : 13
B24
)
Open circuit or poor connector
contact
NG
NG
OK
OK
Thermo unit continuity
between connector 1
E19
(C24SE : 1
E65
) and the
ground
2. Temperature gauge incorrect readings in all ranges
Replace the thermo unit
Thermo unit malfunction
NG
Thermo unit resistance
between connector 1
E19
(C24SE: 1
E65
) and the
ground when disconnecting
the connector (Specified
resistance should indicate)
ELECTRICAL-BODY AND CHASSIS 8A-347
ENGINE COOLANT TEMPERATURE GAUGE (4JJ1-TC/4JK1-TC)
Refer to “Inspection and Repair” in this Manual for a detailed description of the coolant temperature gauge self-
diagnosis procedure.
1. No engine coolant temperature indicates at all
Checkpoint
Trouble
Cause
Countermeasure
Replace the engine coolant
temperature sensor
Engine coolant temperature
sensor malfunction
NG
Replace the meter assembly
Gauge function
1. Disconnect the sensor
connector then connect
3.4W bulb to wire harness
side with ground
2. Check indicating point
when starter SW. is ON
position (Temperature
should indicate)
Gauge malfunction
Repair open circuit or
connector contact
Continuity between 3
E41
and 16
B23
Open circuit or poor connector
contact
NG
NG
OK
OK
Engine coolant temperature
sensor continuity between
connector 3
E41
and the
ground
2. Engine coolant temperature gauge incorrect readings in all ranges
Replace the sensor
The sensor malfunction
NG
Engine coolant temperature
sensor resistance between
connector 3
E41
and the
ground when disconnecting
the connector (Specified
resistance should indicate)
8A-348 ELECTRICAL-BODY AND CHASSIS
TEMPERATURE GAUGE AND THERMO UNIT (HFV6)
1. No temperature indicates at all
Checkpoint
Trouble
Cause
Countermeasure
Replace the thermo unit
Thermo unit malfunction
NG
Replace the case baseboard
assy
Gauge function
1. Disconnect the unit
connector then connect
3.4W bulb to wire harness
side with ground
2. Check indicating point
when starter SW. is ON
position (Temperature
should indicate)
Gauge malfunction
Repair open circuit or
connector contact
Continuity between 8
B96
and 16
B23
Open circuit or poor connector
contact
NG
NG
OK
OK
PIM (Thermo unit) continuity
between connector 8
B96
and the ground
2. Temperature gauge incorrect readings in all ranges
Replace the thermo unit
Thermo unit malfunction
NG
PIM (Thermo unit) resistance
between connector 8
B96
and the ground when
disconnecting the connector
(Specified resistance should
indicate)
ELECTRICAL-BODY AND CHASSIS 8A-349
FUEL GAUGE AND FUEL TANK UNIT (C24SE, 4JJA1T(L), 4JH1-TC, 4JJ1-TC/4JK1-TC)
1. No fuel level indicates at all
Checkpoint
Trouble
Cause
Countermeasure
Replace the tank unit
Open circuit inside the tank
unit
NG
Thermo unit malfunction
Replace the case baseboard
assy
Fuel gauge function
1. Disconnect the tank unit
connector then connect
3.4W bulb to wire harness
side
2. Check indicating point
when starter SW. is ON
position (Fuel level should
indicate)
Gauge malfunction
Repair open circuit or
connector contact
Continuity between
connectors 17
B23
(C24SE :
14
B24
) and 3
F2
Open circuit or poor connector
contact
NG
NG
OK
OK
Tank unit continuity between
connector 3
F2
and ground
2. Fuel gauge gives incorrect readings in all ranges
Replace the tank unit
Tank unit malfunction
NG
Tank unit resistance position
with the float at checking
points (Specified resistance
should indicate)