Isuzu KB P190. Manual — part 198

TROUBLESHOOTING 6 – 7

4. Excessive Fuel Consumption

Step Action Value(s)

Yes

No

1

Was the air cleaner element clogged?

Clean

or

replace the air

cleaner

element. Go

to

Step 2

2

Was the air leakage found from the air intake side of
the turbocharger?

Repair

or

replace the air

intake side of

the

turbocharger. Go

to

Step 3

3

Was the turbocharger working completely?

Go to Step 4

Replace the

turbocharger

4

Was there the fuel leakage?

Repair

or

replace the fuel

leakage part.

Go to Step 5

5

Was the compression pressure OK?

3.0 MPa

(31.0 kg/cm

2

,

441 psi) at

200 rpm

Go to Step 6

Readjust the

valve clearance

or replace the

cylinder head

gasket or

cylinder liner or
piston or piston

ring or valve

and valve seat

6

Was the injection nozzle pressure or spray pattern
normal?

Go to Step 7

Replace the

injection nozzle

7

Are any DTC stored?

Go

to

indicated

DTC Solved

6 – 8 TROUBLESHOOTING

5. Excessive Oil Consumption

Step Action Value(s)

Yes

No

1

Does the air cleaner element conditon OK? (Clogged
or not)

Go to Step 2

Clean or

replace the air

cleaner

element

2

Does PCV (Positive Crankcase Ventilation) Valve
has problem?

Repair

or

replace the

relation parts.

Go to Step 3

3

Was the oil pressure value more than normal value?

Less than

588 kPa (6.0

kg/cm

2

,

85

psi)

Repair or

replace the oil

relief valve

Go to Step 4

4

Inspect the front and rear crankshaft oil seal.

Was the oil leakage found?

Replace the

failure part.

Go to Step 5

5

Was the oil leakage found from any gasket?

Replace

the

wrong gasket

Go to Step 6

6

Inspect the valve stem seal, the valve stem and the
valve guide for worn.
Were any worn found?

Replace the

worn part.

Go to Step 7

7

Was the oil leakage found from the turbocharger oil
seal?

Replace the oil

seal. Go

to

Step 8

8

Was the oil drain pipe of the turbocharger restricted?

Repair

or

replace the oil

drain pipe.

Go to Step 9

9

Was the oil drain passage in the turbocharger center
housing restricted?

Clean

the

center housing

Go to Step 10

10

Does turbine wheel has any impact damage?

Replace

the

turbocharger Go

to

Step 11

11

Are any DTC stored?

Go

to

indicated

DTC Solved

TROUBLESHOOTING 6 – 9

6. Overheating

Step Action Value(s)

Yes

No

1

Was the engine coolant level OK?

Go to Step 2

Replenish the

coolant

2

Was the water leakage or the radiator restriction
found? (Include radiator cap)

Repair

or

replace the

leakage part.

Go to Step 3

3

Was the fan belt slippage found?

Tension

or

replace the fan

belt. Go

to

Step 4

4

Was the fan clutch working completely?

Go to Step 5

Replace the fan

clutch

assembly.

5

Was the oil leakage found from fan clutch?

Replace the fan

clutch

assembly Go

to

Step 6

6

Was the thermostat working normally?

Go to Step 7

Replace the

thermostat.

7

Was the water pump working OK?

Go to Step 8

Replace the

water pump

assembly.

8

Was the restriction by the foreign materials in the
cooling system found? For example, clog the water
hose between the cylinder body and radiator etc..

Clean

or

replace the

clog part.

Go to Step 9

9

Was the water leakage found from the sealing cap
on the cylinder body?

Replace

the

sealing cap or

replace the

cylinder body.

Go to Step 10

10

Are any DTC stored?

Go

to

indicated

DTC. Solved

7. White Exhaust Smoke

Step Action Value(s)

Yes

No

1

Was the compression pressure OK?

3.0 MPa

(31.0 kg/cm

2

,

441 psi) at

200 rpm

Go to Step 2

Readjust the

valve clearance

or replace the

cylinder head

gasket or

cylinder liner or
piston or piston

ring or valve

and relation

parts.

2

Was the PCV (Positive Crankcase Ventilation) valve
working completely?

Go to Step 3

Repair or

replace the
PCV valve.

3

Was the turbocharger working completely?

Go to Step 4

Replace the

turbocharger.

4

Are any DTC stored?

Go

to

indicated

DTC Solved

6 – 10 TROUBLESHOOTING

8. Dark Exhaust Smoke

Step Action Value(s)

Yes

No

1

Was the air cleaner element normal condition?

Go to Step 2

Clean or

replace the air

cleaner

element

2

Was the EGR valve sticking?

Replace

the

EGR valve

Go to Step 3

3

Was the injection nozzle pressure or the injection
spray pattern OK?

Go to Step 4

Replace the

injection nozzle

4

Was the oil leakage found from the turbocharger oil
seal?

Replace the oil

seal Go

to

Step 5

5

Was the oil drain pipe of the turbocharger restricted?

Repair

or

replace the oil

drain pipe

Go to Step 6

6

Was restricted the oil drain passage in the
turbocharger center housing restricted?

Clean

the

center housing

Go to Step 7

7

Does turbine wheel has any impact damage?

Replace

the

turbocharger Go

to

Step 8

8

Does PCV (Positive Crankcase Ventilation) Valve
has problem?

Repair

or

replace the

relation parts

Go to Step 9

9

Are any DTC stored?

Go

to

indicated

DTC Solved