Nissan Murano Z50 (2003 year). Manual — part 101
DTC P0340, P0345 CMP SENSOR (PHASE)
EC-335
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
Component Inspection
ABS004GB
CAMSHAFT POSITION SENSOR (PHASE)
1.
Loosen the fixing bolt of the sensor.
2.
Disconnect camshaft position sensor (PHASE) harness connector.
3.
Remove the sensor.
4.
Visually check the sensor for chipping.
5.
Check resistance as shown in the figure.
Removal and Installation
ABS004GC
CAMSHAFT POSITION SENSOR (PHASE)
Refer to
PBIB0563E
Terminal No. (Polarity)
Resistance
Ω
[at 25
°
C (77
°
F)]
1 (+) - 2 (-)
Except 0 or
∞
1 (+) - 3 (-)
2 (+) - 3 (-)
PBIB0564E
EC-336
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision; 2004 April
2003 Murano
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
PFP:20905
On Board Diagnosis Logic
ABS004GD
The ECM monitors the switching frequency ratio of heated oxygen
sensors 1 and 2.
A three way catalyst (manifold) with high oxygen storage capacity
will indicate a low switching frequency of heated oxygen sensor 2.
As oxygen storage capacity decreases, the heated oxygen sensor 2
switching frequency will increase.
When the frequency ratio of heated oxygen sensors 1 and 2
approaches a specified limit value, the three way catalyst (manifold)
malfunction is diagnosed.
DTC Confirmation Procedure
ABS004GE
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
WITH CONSULT-II
TESTING CONDITION:
Do not hold engine speed for more than the specified minutes below.
1.
Turn ignition switch “ON” and select “DATA MONITOR” mode
with CONSULT-II.
2.
Start engine and warm it up to the normal operating tempera-
ture.
3.
Turn ignition switch “OFF” and wait at least 10 seconds.
4.
Start engine and keep the engine speed between 3,500 and
4,000 rpm for at least one minute under no load.
5.
Let engine idle for one minutes.
6.
Make sure that “COOLAN TEMP/S” indicates more than 70
°
C
(158
°
F).
If not, warm up engine and go to next step when “COOLAN
TEMP/S” indication reaches to 70
°
C (158
°
F).
7.
Open engine hood.
SEF484YF
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0420
0420
(Bank 1)
Catalyst system effi-
ciency below threshold
●
Three way catalyst (manifold) does not oper-
ate properly.
●
Three way catalyst (manifold) does not have
enough oxygen storage capacity.
●
Three way catalyst (manifold)
●
Exhaust tube
●
Intake air leaks
●
Fuel injectors
●
Fuel injector leaks
●
Spark plug
●
Improper ignition timing
P0430
0430
(Bank 2)
SEF189Y
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-337
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
8.
Select “DTC & SRT CONFIRMATION” then “SRT WORK SUP-
PORT” mode with CONSULT-II.
9.
Rev engine up to 2,000 to 3,000 rpm and hold it for 3 consecu-
tive minutes then release the accelerator pedal completely.
If “INCMP” of “CATALYST” changed to “CMPLT”, go to step 12.
10. Wait 5 seconds at idle.
11. Rev engine up to 2,000 to 3,000 rpm and maintain it until
“INCMP” of “CATALYST” changes to “CMPLT” (It will take
approximately 5 minutes).
If not “CMPLT”, stop engine and cool it down to less than 70
°
C
(158
°
F) and then retest from step 1.
12. Select “SELF-DIAG RESULTS” mode with CONSULT-II.
13. Confirm that the 1st trip DTC is not detected.
If the 1st trip DTC is detected, go to
.
Overall Function Check
ABS004GF
Use this procedure to check the overall function of the three way catalyst (manifold). During this check, a DTC
might not be confirmed.
WITH GST
1.
Turn ignition switch “OFF” and wait at least 10 seconds.
2.
Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
3.
Let engine idle for one minutes.
4.
Open engine hood.
5.
Set voltmeters probes between ECM terminals 35 [HO2S1
(bank 1) signal], 16 [HO2S1 (bank 2) signal] and engine ground,
and ECM terminals 74 [HO2S2 (bank 1) signal], 55 [HO2S2
(bank 2) signal] and engine ground.
6.
Keep engine speed at 2,000 rpm constant under no load.
SEF940Z
SEF941Z
SEF535Z
PBIB1107E
EC-338
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision; 2004 April
2003 Murano
7.
Make sure that the voltage switching frequency (high & low)
between ECM terminals 74 and engine ground, or 55 and
engine ground is very less than that of ECM terminals 35 and
engine ground, or 16 and engine ground.
Switching frequency ratio = A/B
A: Heated oxygen sensor 2 voltage switching frequency
B: Heated oxygen sensor 1 voltage switching frequency
This ratio should be less than 0.75.
If the ratio is greater than above, it means three way catalyst
(manifold) does not operate properly. Go to
.
NOTE:
If the voltage at terminal 35 or 16 does not switch periodically more than 5 times within 10 seconds at step 7,
perform trouble diagnosis for “DTC P0133, P0153” first. (See
Diagnostic Procedure
ABS004GG
1.
CHECK EXHAUST SYSTEM
Visually check exhaust tubes and muffler for dent.
OK or NG
OK
>> GO TO 2.
NG
>> Repair or replace.
2.
CHECK EXHAUST GAS LEAK
1.
Start engine and run it at idle.
2.
Listen for an exhaust gas leak before the three way catalyst (manifold).
OK or NG
OK
>> GO TO 3.
NG
>> Repair or replace.
3.
CHECK INTAKE AIR LEAK
Listen for an intake air leak after the mass air flow sensor.
OK or NG
OK
>> GO TO 4.
NG
>> Repair or replace.
PBIB1108E
SEC502D
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
EC-339
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
4.
CHECK IGNITION TIMING
Check the following items. Refer to
OK or NG
OK
>> GO TO 5.
NG
>> Follow the
5.
CHECK INJECTORS
1.
Stop engine and then turn ignition switch “ON”.
2.
Check voltage between ECM terminals 21, 22, 23, 40, 41, 42
and ground with CONSULT-II or tester.
Refer to Wiring Diagram for Injectors,
OK or NG
OK
>> GO TO 6.
NG
>> Perform
EC-619, "Diagnostic Procedure"
6.
CHECK IGNITION SPARK
1.
Turn ignition switch “OFF”.
2.
Disconnect ignition coil assembly from rocker cover.
3.
Connect a known-good spark plug to the ignition coil assembly.
4.
Disconnect injector harness connectors.
5.
Place end of spark plug against a suitable ground and crank engine.
6.
Check for spark.
OK or NG
OK
>> GO TO 7.
NG
>> Check ignition coil with power transistor and their circuit.
Refer to
.
Items
Specifications
Target idle speed
650
±
50 rpm (in “P” or “N” position)
Ignition timing
15
±
5
°
BTDC (in “P” or “N” position)
Battery voltage should exist.
PBIB1172E
SEF575Q
EC-340
DTC P0420, P0430 THREE WAY CATALYST FUNCTION
Revision; 2004 April
2003 Murano
7.
CHECK INJECTOR
1.
Turn ignition switch “OFF”.
2.
Remove injector assembly.
Refer to
EM-38, "FUEL INJECTOR AND FUEL TUBE"
Keep fuel hose and all injectors connected to injector gallery.
3.
Reconnect all injector harness connectors.
4.
Disconnect all ignition coil harness connectors.
5.
Turn ignition switch “ON”.
Make sure fuel does not drip from injector.
OK or NG
OK (Does not drip.)>>GO TO 8.
NG (Drips.)>>Replace the injector(s) from which fuel is dripping.
8.
CHECK INTERMITTENT INCIDENT
Refer to
EC-151, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
.
Trouble is fixed.>>INSPECTION END
Trouble is not fixed.>>Replace three way catalyst (manifold).
DTC P0441 EVAP CONTROL SYSTEM
EC-341
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
DTC P0441 EVAP CONTROL SYSTEM
PFP:14950
System Description
ABS004GH
NOTE:
If DTC P0441 is displayed with other DTC such as P2122, P2123, P2127, P2128 or P2138, first perform
trouble diagnosis for other DTC.
In this evaporative emission (EVAP) control system, purge flow occurs during non-closed throttle conditions.
Purge volume is related to air intake volume. Under normal purge conditions (non-closed throttle), the EVAP
canister purge volume control solenoid valve is open to admit purge flow. Purge flow exposes the EVAP con-
trol system pressure sensor to intake manifold vacuum.
On Board Diagnosis Logic
ABS004GI
Under normal conditions (non-closed throttle), sensor output voltage indicates if pressure drop and purge flow
are adequate. If not, a malfunction is determined.
DTC Confirmation Procedure
ABS004GJ
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Always perform test at a temperature of 5
°
C (41
°
F) or more.
PBIB1026E
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0441
0441
EVAP control system
incorrect purge flow
EVAP control system does not operate prop-
erly, EVAP control system has a leak between
intake manifold and EVAP control system pres-
sure sensor.
●
EVAP canister purge volume control
solenoid valve stuck closed
●
EVAP control system pressure sensor
and the circuit
●
Loose, disconnected or improper con-
nection of rubber tube
●
Blocked rubber tube
●
Cracked EVAP canister
●
EVAP canister purge volume control
solenoid valve circuit
●
Accelerator pedal position sensor
●
Blocked purge port
●
EVAP canister vent control valve
EC-342
DTC P0441 EVAP CONTROL SYSTEM
Revision; 2004 April
2003 Murano
WITH CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Turn ignition switch “OFF” and wait at least 10 seconds.
3.
Start engine and let it idle for at least 70 seconds.
4.
Select “PURG FLOW P0441” of “EVAPORATIVE SYSTEM” in “DTC CONFIRMATION” mode with CON-
SULT-II.
5.
Touch “START”.
If “COMPLETED” is displayed, go to step 7.
6.
When the following conditions are met, “TESTING” will be displayed on the CONSULT-II screen. Maintain
the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take at least 35 seconds.)
If “TESTING” is not changed for a long time, retry from step 2.
7.
Make sure that “OK” is displayed after touching “SELF-DIAG RESULTS”. If “NG” is displayed, refer to
.
Overall Function Check
ABS004GK
Use this procedure to check the overall monitoring function of the EVAP control system purge flow monitoring.
During this check, a DTC might not be confirmed.
WITH GST
1.
Lift up drive wheels.
2.
Start engine (VDC switch “OFF”) and warm it up to normal operating temperature.
3.
Turn ignition switch “OFF”, wait at least 10 seconds.
4.
Start engine and wait at least 70 seconds.
5.
Set voltmeter probes to ECM terminals 32 (EVAP control system
pressure sensor signal) and ground.
6.
Check EVAP control system pressure sensor value at idle speed
and note it.
7.
Establish and maintain the following conditions for at least 1
minute.
8.
Verify that EVAP control system pressure sensor value stays 0.1V less than the value at idle speed (mea-
sured at step 6) for at least 1 second.
Selector lever
Suitable position
Vehicle speed
32 - 120 km/h (20 - 75 MPH)
ENG SPEED
500 - 3,000 rpm
B/FUEL SCHDL
1.3 - 9.0 msec
Engine coolant temperature
70 - 100
°
C (158 - 212
°
F)
PBIB0826E
Air conditioner switch
ON
Headlamp switch
ON
Rear window defogger switch
ON
Engine speed
Approx. 3,000 rpm
Gear position
Any position other than “P”, “N” or “R”
PBIB1109E
DTC P0441 EVAP CONTROL SYSTEM
EC-343
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
9.
EC-343, "Diagnostic Procedure"
Diagnostic Procedure
ABS004GL
1.
CHECK EVAP CANISTER
1.
Turn ignition switch “OFF”.
2.
Check EVAP canister for cracks.
OK or NG
OK (With CONSULT-II)>>GO TO 2.
OK (Without CONSULT-II)>>GO TO 3.
NG
>> Replace EVAP canister.
2.
CHECK PURGE FLOW
With CONSULT-II
1.
Disconnect vacuum hose connected to EVAP canister purge volume control solenoid valve at EVAP ser-
vice port and install vacuum gauge. For the location of EVAP service port, refer to
2.
Start engine and let it idle.
3.
Select “PURG VOL CONT/V” in “ACTIVE TEST” mode with CONSULT-II.
4.
Rev engine up to 2,000 rpm.
5.
Touch “Qd” and “Qu” on CONSULT-II screen to adjust “PURG
VOL CONT/V” opening and check vacuum existence.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 4.
3.
CHECK PURGE FLOW
Without CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Stop engine.
3.
Disconnect vacuum hose connected to EVAP canister purge volume control solenoid valve at EVAP ser-
vice port and install vacuum gauge. For the location of EVAP service port, refer to
4.
Start engine and let it idle for at least 80 seconds.
5.
Check vacuum gauge indication when revving engine up to 2,000 rpm.
6.
Release the accelerator pedal fully and let idle.
OK or NG
OK
>> GO TO 7.
NG
>> GO TO 4.
PURG VOL CONT/V
Vacuum
100.0%
Should exist.
0.0%
Should not exist.
PBIB0147E
Vacuum should exist.
Vacuum should not exist.
EC-344
DTC P0441 EVAP CONTROL SYSTEM
Revision; 2004 April
2003 Murano
4.
CHECK EVAP PURGE LINE
1.
Turn ignition switch “OFF”.
2.
Check EVAP purge line for improper connection or disconnection.
Refer to
EC-653, "EVAPORATIVE EMISSION LINE DRAWING"
.
OK or NG
OK
>> GO TO 5.
NG
>> Repair it.
5.
CHECK EVAP PURGE HOSE AND PURGE PORT
1.
Disconnect purge hoses connected to EVAP service port A and
EVAP canister purge volume control solenoid valve B .
2.
Blow air into each hose and EVAP purge port C .
3.
Check that air flows freely.
OK or NG
OK (With CONSULT-II)>>GO TO 6.
OK (Without CONSULT-II)>>GO TO 7.
NG
>> Repair or clean hoses and/or purge port.
6.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1.
Start engine.
2.
Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
OK or NG
OK
>> GO TO 8.
NG
>> GO TO 7.
7.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to
EC-361, "Component Inspection"
OK or NG
OK
>> GO TO 8.
NG
>> Replace EVAP canister purge volume control solenoid valve.
SEF367U
SEF368U
PBIB0147E
DTC P0441 EVAP CONTROL SYSTEM
EC-345
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
8.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
1.
Disconnect EVAP control system pressure sensor harness connector.
2.
Check connectors for water.
OK or NG
OK
>> GO TO 9.
NG
>> Replace EVAP control system pressure sensor.
9.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR FUNCTION
Refer to “DTC Confirmation Procedure” for DTC P0452
, P0453
.
OK or NG
OK
>> GO TO 10.
NG
>> Replace EVAP control system pressure sensor.
10.
CHECK RUBBER TUBE FOR CLOGGING
1.
Disconnect rubber tube connected to EVAP canister vent control valve.
2.
Check the rubber tube for clogging.
OK or NG
OK
>> GO TO 11.
NG
>> Clean the rubber tube using an air blower.
11.
CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to
EC-368, "Component Inspection"
OK or NG
OK
>> GO TO 12.
NG
>> Replace EVAP canister vent control valve.
12.
CHECK EVAP PURGE LINE
Inspect EVAP purge line (pipe and rubber tube). Check for evidence of leaks.
Refer to
EC-653, "EVAPORATIVE EMISSION LINE DRAWING"
.
OK or NG
OK
>> GO TO 13.
NG
>> Replace it.
13.
CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
>> GO TO 14.
14.
CHECK INTERMITTENT INCIDENT
Refer to
EC-151, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END
Water should not exist.
EC-346
DTC P0442 EVAP CONTROL SYSTEM
Revision; 2004 April
2003 Murano
DTC P0442 EVAP CONTROL SYSTEM
PFP:14950
On Board Diagnosis Logic
ABS004GM
This diagnosis detects leaks in the EVAP purge line using engine intake manifold vacuum.
If pressure does not increase, the ECM will check for leaks in the line between the fuel tank and EVAP canister
purge volume control solenoid valve, under the following “Vacuum test” conditions.
The EVAP canister vent control valve is closed to shut the EVAP purge line off. The EVAP canister purge vol-
ume control solenoid valve will then be opened to depressurize the EVAP purge line using intake manifold
vacuum. After this occurs, the EVAP canister purge volume control solenoid valve will be closed.
PBIB1026E
DTC P0442 EVAP CONTROL SYSTEM
EC-347
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
CAUTION:
●
Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect fuel filler cap is used,
the MIL may come on.
●
If the fuel filler cap is not tightened properly, the MIL may come on.
●
Use only a genuine NISSAN rubber tube as a replacement.
DTC Confirmation Procedure
ABS004VH
NOTE:
●
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and
wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
●
Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is
placed on flat level surface.
●
Always perform test at a temperature of 0 to 30
°
C (32 to 86
°
F).
WITH CONSULT-II
1.
Turn ignition switch “ON”.
2.
Turn ignition switch “OFF” and wait at least 10 seconds.
3.
Turn ignition switch “ON” and select “DATA MONITOR” mode with CONSULT-II.
4.
Make sure that the following conditions are met.
COOLAN TEMP/S: 0 - 70
°
C (32 - 158
°
F)
INT/A TEMP SE: 0 - 30
°
C (32 - 86
°
F)
5.
Select “EVAP SML LEAK P0442/P1442” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode
with CONSULT-II.
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0442
0442
EVAP control system
small leak detected
(negative pressure)
EVAP control system has a leak, EVAP
control system does not operate prop-
erly.
●
Incorrect fuel tank vacuum relief valve
●
Incorrect fuel filler cap used
●
Fuel filler cap remains open or fails to close.
●
Foreign matter caught in fuel filler cap.
●
Leak is in line between intake manifold and
EVAP canister purge volume control solenoid
valve.
●
Foreign matter caught in EVAP canister vent
control valve.
●
EVAP canister or fuel tank leaks
●
EVAP purge line (pipe and rubber tube) leaks
●
EVAP purge line rubber tube bent
●
Blocked or bent rubber tube to EVAP control sys-
tem pressure sensor
●
Loose or disconnected rubber tube
●
EVAP canister vent control valve and the circuit
●
EVAP canister purge volume control solenoid
valve and the circuit
●
Fuel tank temperature sensor
●
O-ring of EVAP canister vent control valve is
missing or damaged
●
EVAP canister is saturated with water
●
EVAP control system pressure sensor
●
Fuel level sensor and the circuit
●
Refueling EVAP vapor cut valve
●
ORVR system leaks
EC-348
DTC P0442 EVAP CONTROL SYSTEM
Revision; 2004 April
2003 Murano
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within the range displayed on the CONSULT-II screen, go to
6.
Make sure that “OK” is displayed.
If “NG” is displayed, refer to
EC-349, "Diagnostic Procedure"
NOTE:
Make sure that EVAP hoses are connected to EVAP canister
purge volume control solenoid valve properly.
WITH GST
NOTE:
Be sure to read the explanation of “Driving Pattern” on
before driving vehicle.
1.
Start engine.
2.
Drive vehicle according to “Driving Pattern”,
3.
Stop vehicle.
4.
Select “MODE 1” with GST.
●
If SRT of EVAP system is not set yet, go to the following step.
●
If SRT of EVAP system is set, the result will be OK.
5.
Turn ignition switch “OFF” and wait at least 10 seconds.
6.
Start engine.
It is not necessary to cool engine down before driving.
7.
Drive vehicle again according to the “Driving Pattern”,
8.
Stop vehicle.
9.
Select “MODE 3” with GST.
●
If P0442 is displayed on the screen, go to
EC-349, "Diagnostic Procedure"
●
If P0441 is displayed on the screen, go to “Diagnostic Procedure” for DTC P0441,
●
If P0441 and P0442 are not displayed on the screen, go to the following step.
10. Select “MODE 1” with GST.
●
If SRT of EVAP system is set, the result will be OK.
●
If SRT of EVAP system is not set, go to step 6.
PBIB0829E
SEC763C
DTC P0442 EVAP CONTROL SYSTEM
EC-349
C
D
E
F
G
H
I
J
K
L
M
A
EC
Revision; 2004 April
2003 Murano
Diagnostic Procedure
ABS004GO
1.
CHECK FUEL FILLER CAP DESIGN
1.
Turn ignition switch “OFF”.
2.
Check for genuine NISSAN fuel filler cap design.
OK or NG
OK
>> GO TO 2.
NG
>> Replace with genuine NISSAN fuel filler cap.
2.
CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
OK or NG
OK
>> GO TO 3.
NG
>> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
3.
CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK
>> GO TO 5.
NG
>> GO TO 4.
4.
CHECK FUEL TANK VACUUM RELIEF VALVE
Refer to
EC-655, "FUEL TANK VACUUM RELIEF VALVE (BUILT INTO FUEL FULLER CAP)"
.
OK or NG
OK
>> GO TO 5.
NG
>> Replace fuel filler cap with a genuine one.
SEF915U
EC-350
DTC P0442 EVAP CONTROL SYSTEM
Revision; 2004 April
2003 Murano
5.
INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter and pres-
sure pump to EVAP service port securely. For the location of EVAP
service port, refer to
EC-653, "EVAPORATIVE EMISSION LINE
NOTE:
Improper installation of the EVAP service port adapter to the EVAP service port may cause leaking.
Models with CONSULT-II>>GO TO 6.
Models without CONSULT-II>>GO TO 7.
PBIB1355E
SEF916U
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.