Nissan Frontier D22. Manual — part 463
DTC P0455 EVAP CONTROL SYSTEM
EC-955
[VG33E]
C
D
E
F
G
H
I
J
K
L
M
A
EC
12.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION
Without CONSULT-II
1.
Start engine and warm it up to normal operating temperature.
2.
Stop engine.
3.
Disconnect vacuum hose to EVAP canister purge volume control solenoid valve at EVAP service port.
4.
Start engine and let it idle for at least 80 seconds.
5.
Check vacuum hose for vacuum when revving engine up to 2,000 rpm.
OK or NG
OK
>> GO TO 15.
NG
>> GO TO 13.
13.
CHECK VACUUM HOSE
Check vacuum hoses for clogging or disconnection. Refer to
OK or NG
OK (With CONSULT-II)>>GO TO 14.
OK (Without CONSULT-II)>>GO TO 15.
NG
>> Repair or reconnect the hose.
14.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1.
Start engine.
2.
Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
If OK, inspection end. If NG, go to following step.
3.
Check air passage continuity.
OK or NG
OK
>> GO TO 16.
NG
>> Replace EVAP canister purge volume control solenoid
valve.
Vacuum should exist.
SEF985Y
Condition
PURG VOL CONT/V value
Air passage continuity between A
and B
100%
Yes
0%
No
SEF660U
EC-956
[VG33E]
DTC P0455 EVAP CONTROL SYSTEM
15.
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Without CONSULT-II
Check air passage continuity.
OK or NG
OK
>> GO TO 16.
NG
>> Replace EVAP canister purge volume control solenoid valve.
Condition
Air passage continuity between A
and B
12V direct current supply
between terminals 1 and 2
Yes
No supply
No
SEF661U
AEC652A
DTC P0455 EVAP CONTROL SYSTEM
EC-957
[VG33E]
C
D
E
F
G
H
I
J
K
L
M
A
EC
16.
CHECK FUEL TANK TEMPERATURE SENSOR
1.
Remove fuel level sensor unit.
2.
Check resistance between fuel level sensor unit terminals T and E by heating with hot water or heat gun
as shown in the figure.
OK or NG
OK
>> GO TO 17.
NG
>> Replace fuel tank temperature sensor.
Temperature
°C (°F)
Resistance k
Ω
20 (68)
2.3 - 2.7
50 (122)
0.79 - 0.90
PBIB1425E
LEC764
EC-958
[VG33E]
DTC P0455 EVAP CONTROL SYSTEM
17.
CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1.
Remove EVAP control system pressure sensor with its harness
connector connected.
2.
Remove hose from EVAP control system pressure sensor.
3.
Turn ignition switch ON.
4.
Use pump to apply vacuum and pressure to EVAP control sys-
tem pressure sensor as shown in figure.
5.
Check input voltage between ECM terminal 62 and ground.
CAUTION:
●
Always calibrate the vacuum pump gauge when using it.
●
Do not apply below
−93.3 kPa (−700 mmHg, −27.56 inHg) or
over 101.3 kPa (760 mmHg, 29.92 inHg) of pressure.
OK or NG
OK
>> GO TO 18.
NG
>> Replace EVAP control system pressure sensor.
18.
CHECK INTERMITTENT INCIDENT
EC-696, "TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT"
>> INSPECTION END.
AEC651A
Applied vacuum
Voltage V
Not applied
1.8 - 4.8
−26.7 kpa (−200 mmHg, −7.87 inHg)
2.1 to 2.5V lower than above value
PBIB1426E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.