Nissan Qashqai J11. Manual — part 2180
DAS-134
< DTC/CIRCUIT DIAGNOSIS >
[DRIVER ASSISTANCE SYSTEM]
U111B SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
LHD models
RHD models
Is the inspection result normal?
YES
>> Replace around view monitor control unit. Refer to
AV-267, "Removal and Installation"
NO
>> Replace side camera RH. Refer to
AV-269, "Removal and Installation"
WITHOUT PUMP CONTROL UNIT
1.
CHECK SIDE CAMERA RH POWER SUPPLY AND GROUND CIRCUIT CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect around view monitor control unit and side camera RH connectors.
3.
Check continuity between around view monitor control unit connector and side camera RH connector.
LHD models
RHD models
4.
Check continuity between around view monitor control unit connector and ground.
LHD models
Around view monitor control unit connector
Condition
Reference value
(+)
(
−
)
Terminal
Terminal
65
66
CAMERA switch is ON or se-
lector lever in R (reverse).
Around view monitor control unit connector
Condition
Reference value
(+)
(
−
)
Terminal
Terminal
59
60
CAMERA switch is ON or se-
lector lever in R (reverse).
JSNIA0834GB
JSNIA0834GB
Around view monitor control unit
Side camera RH
Continuity
Connector
Terminals
Connector
Terminals
M95
34
D27
7
Existed
33
8
Around view monitor control unit
Side camera RH
Continuity
Connector
Terminals
Connector
Terminals
M95
30
D40
7
Existed
29
8
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M95
34
Not existed
DAS
U111B SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
DAS-135
< DTC/CIRCUIT DIAGNOSIS >
[DRIVER ASSISTANCE SYSTEM]
C
D
E
F
G
H
I
J
K
L
M
B
N
P
A
RHD models
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness or connectors.
2.
CHECK SIDE CAMERA RH POWER SUPPLY VOLTAGE
1.
Connect around view monitor control unit and side camera RH connectors.
2.
Turn ignition switch ON.
3.
Check voltage between around view monitor control unit connector and ground.
LHD models
RHD models
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace around view monitor control unit. Refer to
AV-267, "Removal and Installation"
3.
CHECK SIDE CAMERA RH IMAGE SIGNAL AND IMAGE SIGNAL GROUND CIRCUIT CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect around view monitor control unit and side camera RH connectors.
3.
Check continuity between around view monitor control unit connector and side camera RH connector.
LHD models
RHD models
4.
Check continuity between around view monitor control unit connector and ground.
LHD models
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M95
30
Not existed
Around view monitor control unit
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
M95
34
—
CAMERA switch is ON or
selector lever in R (re-
verse).
6.0 V
Around view monitor control unit
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
M95
30
—
CAMERA switch is ON or
selector lever in R (re-
verse).
6.0 V
Around view monitor control unit
Side camera RH
Continuity
Connector
Terminals
Connector
Terminals
M95
36
D27
16
Existed
35
15
Around view monitor control unit
Side camera RH
Continuity
Connector
Terminals
Connector
Terminals
M95
32
D40
16
Existed
31
15
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M95
36
Not existed
DAS-136
< DTC/CIRCUIT DIAGNOSIS >
[DRIVER ASSISTANCE SYSTEM]
U111B SIDE CAMERA RH IMAGE SIGNAL CIRCUIT
RHD models
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness or connectors.
4.
CHECK SIDE CAMERA RH IMAGE SIGNAL
1.
Connect around view monitor control unit and side camera RH connectors.
2.
Turn ignition switch ON.
3.
Check signal between the terminals of around view monitor control unit connector.
LHD models
RHD models
Is the inspection result normal?
YES
>> Replace around view monitor control unit. Refer to
AV-267, "Removal and Installation"
NO
>> Replace side camera RH. Refer to
AV-269, "Removal and Installation"
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M95
32
Not existed
Around view monitor control unit connector
Condition
Reference value
(+)
(
−
)
Terminal
Terminal
36
35
CAMERA switch is ON or se-
lector lever in R (reverse).
Around view monitor control unit connector
Condition
Reference value
(+)
(
−
)
Terminal
Terminal
32
31
CAMERA switch is ON or se-
lector lever in R (reverse).
JSNIA0834GB
JSNIA0834GB
DAS
U111C FRONT CAMERA IMAGE SIGNAL CIRCUIT
DAS-137
< DTC/CIRCUIT DIAGNOSIS >
[DRIVER ASSISTANCE SYSTEM]
C
D
E
F
G
H
I
J
K
L
M
B
N
P
A
U111C FRONT CAMERA IMAGE SIGNAL CIRCUIT
DTC Logic
INFOID:0000000010416872
DTC DETECTION LOGIC
Diagnosis Procedure
INFOID:0000000010416873
WITH PUMP CONTROL UNIT
1.
CHECK FRONT CAMERA POWER SUPPLY AND GROUND CIRCUIT CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect around view monitor control unit and front camera connectors.
3.
Check continuity between around view monitor control unit connector and front camera connector.
4.
Check continuity between around view monitor control unit connector and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Repair or replace harness or connectors.
2.
CHECK FRONT CAMERA POWER SUPPLY VOLTAGE
1.
Connect around view monitor control unit and front camera connectors.
2.
Turn ignition switch ON.
3.
Check voltage between around view monitor control unit connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace around view monitor control unit. Refer to
AV-267, "Removal and Installation"
3.
CHECK FRONT CAMERA IMAGE SIGNAL AND IMAGE SIGNAL GROUND CIRCUIT CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect around view monitor control unit and front camera connectors.
3.
Check continuity between around view monitor control unit connector and front camera connector.
CONSULT Display
DTC Detection Condition
Possible Cause
FRONT CAMERA IMAGE SIG-
NAL
[U111C]
Front camera image signal circuit open or short.
Check front camera image signal circuit.
Around view monitor control unit
Front camera
Continuity
Connector
Terminals
Connector
Terminals
M8
68
E106
2
Existed
70
1
Around view monitor control unit
Ground
Continuity
Connector
Terminal
M8
68
Not existed
Around view monitor control unit
Ground
Condition
Voltage
(Approx.)
Connector
Terminal
M8
68
—
CAMERA switch is ON or
selector lever in R (re-
verse).
6.0 V
Around view monitor control unit
Front camera
Continuity
Connector
Terminals
Connector
Terminals
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.