Nissan Qashqai J11. Manual — part 2034

MWI-72

< DTC/CIRCUIT DIAGNOSIS >

OIL LEVEL SENSOR SIGNAL CIRCUIT

OIL LEVEL SENSOR SIGNAL CIRCUIT

Component Function Check

INFOID:0000000010329989

1.

CHECK COMBINATION METER INPUT SIGNAL

Select the “Data Monitor” for the “METER/M&A” and check the “OIL W/L” monitor value.

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000010329990

1.

CHECK OIL LEVEL SENSOR CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect combination meter connector and oil level sensor connector.

3.

Check continuity between combination meter connector and oil level sensor harness connector.

*1: K9K engine models

*2: R9M engine models

*3: MR16DDT engine models

4.

Check continuity between combination meter harness connector and ground.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Repair harness or connector.

Component Inspection

INFOID:0000000010329991

1.

CHECK OIL LEVEL SENSOR

Check continuity between oil level sensor and ground.

Is the inspection result normal?

“OIL W/L”

Ignition switch ON

: On

Engine running

: Off

Terminals

Continuity

(+)

(

)

Combination meter

Oil level sensor

Connector

Terminal

Connector

Terminal

M52

49

F141

*1

F142

*2

F216

*3

1

Existed

Terminals

Continuity

(+)

(

)

Combination meter

Ground

Connector

Terminal

M52

49

Not existed

Condition

Continuity

Engine stopped

Existed

Engine running

Not existed

MWI

OIL LEVEL SENSOR SIGNAL CIRCUIT

MWI-73

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

YES

>> INSPECTION END

NO

>> Replace oil level sensor.

MWI-74

< DTC/CIRCUIT DIAGNOSIS >

AMBIENT SENSOR SIGNAL CIRCUIT

AMBIENT SENSOR SIGNAL CIRCUIT

Diagnosis Procedure

INFOID:0000000010329992

1.

CHECK AMBIENT SENSOR CIRCUIT

1.

Turn ignition switch OFF.

2.

Disconnect combination meter connector and ouotside temperature sender connector.

3.

Check continuity between combination meter harness connector and ambient sensor harness connector.

4.

Check continuity between combination meter harness connector and ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Repair harness or connector.

2.

CHECK AMBIENT SENSOR GROUND CIRCUIT

Check continuity between combination meter harness connector and ambient sensor harness connector.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Repair harness or connector.

Component Inspection

INFOID:0000000010329993

Refer to

HAC-130, "Removal and Installation"

.

Terminals

Continuity

(+)

(

)

Combination meter

Ambient sensor

Connector

Terminal

Connector

Terminal

M51

15

E12

1

Existed

Terminals

Continuity

(+)

(

)

Combination meter

Ground

Connector

Terminal

M51

1

Not existed

Terminals

Continuity

(+)

(

)

Combination meter

Ambient sensor sender

Connector

Terminal

Connector

Terminal

M51

20

E12

2

Existed

MWI

METER CONTROL SWITCH SIGNAL CIRCUIT

MWI-75

< DTC/CIRCUIT DIAGNOSIS >

C

D

E

F

G

H

I

J

K

L

M

B

A

O

P

METER CONTROL SWITCH SIGNAL CIRCUIT

Diagnosis Procedure

INFOID:0000000010435886

Regarding Wiring Diagram information, refer to

MWI-42, "Wiring Diagram"

.

1.

CHECK METER CONTROL SWITCH SIGNAL

1.

Turn ignition switch ON.

2.

Check voltage between the following terminals of the meter control switch harness connector M53.

Is the inspection result normal?

YES

>> Inspection End.

NO

>> GO TO 2.

2.

CHECK METER CONTROL SWITCH HARNESS

1.

Turn ignition switch OFF.

2.

Disconnect combination meter harness connector M51 and meter control switch harness connector M53.

3.

Check continuity between combination meter harness connector M51 and meter control switch harness
connector M53.

4.

Check continuity between combination meter harness connector and ground.

Is the inspection result normal?

YES

>> Inspection End.

NO

>> Repair or replace harness or connectors.

Meter control switch

Condition

Voltage

(Approx.)

Connector

Terminals

(+)

(

)

M53

7

4

When illumination control switch (

) is pressed

0 V

Other than the above

5 V

5

When trip reset switch is pressed

0 V

Other than the above

5 V

6

When illumination control switch (+) is pressed

0 V

Other than the above

5 V

Combination meter

Meter control switch

Continuity

Connector

Terminal

Connector

Terminal

M51

18

M53

5

Yes

37

7

36

6

17

4

Combination meter

Ground

Continuity

Connector

Terminal

M51

18

No

37

36

17