Nissan Qashqai J11. Manual — part 1525
SUNSHADE SYSTEM
RF-11
< WIRING DIAGRAM >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
JRKWE4043GB
RF-12
< WIRING DIAGRAM >
SUNSHADE SYSTEM
JRKWE4044GB
DIAGNOSIS AND REPAIR WORKFLOW
RF-13
< BASIC INSPECTION >
C
D
E
F
G
H
I
J
L
M
A
B
RF
N
O
P
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000010427877
DETAILED FLOW
1.
OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain the malfunction information (conditions and environment when the malfunc-
tion occurred) as much as possible when the customer brings the vehicle in.
>> GO TO 2.
2.
REPRODUCE THE MALFUNCTION INFORMATION
Check the malfunction on the vehicle that the customer describes.
Inspect the relation of the symptoms and the condition when the symptoms occur.
>> GO TO 3.
3.
IDENTIFY THE MALFUNCTIONING SYSTEM WITH “SYMPTOM DIAGNOSIS”
Use “Symptom diagnosis” from the symptom inspection result in step 2 and then identify where to start per-
forming the diagnosis based on possible causes and symptoms.
>> GO TO 4.
4.
IDENTIFY THE MALFUNCTIONING PARTS WITH “COMPONENT DIAGNOSIS”
Perform the diagnosis with “Component diagnosis” of the applicable system.
>> GO TO 5.
5.
REPAIR OR REPLACE THE MALFUNCTIONING PARTS
Repair or replace the specified malfunctioning parts.
>> GO TO 6.
6.
FINAL CHECK
Check that malfunctions are not reproduced when obtaining the malfunction information from the customer,
referring to the symptom inspection result in step 2.
Are the malfunctions corrected?
YES
>> INSPECTION END
NO
>> GO TO 3.
RF-14
< BASIC INSPECTION >
SYSTEM INITIALIZATION
SYSTEM INITIALIZATION
Description
INFOID:0000000010286632
Initialization of system should be conducted after the following conditions. Refer to
• When the sunshade motor assembly is changed.
• When the sunshade does not operate normally. (Incomplete initialization conditions)
Work Procedure
INFOID:0000000010286633
1.
STEP 1
1.
Return sunshade to closed position.
2.
Release the close switch once, press the close switch again, press and hold the switch until shade is fully
closed. (About 30 seconds)
3.
Release the switch again, and press the close switch within the first 10 seconds. (keep pressing the
switch)
4.
After 3 or 4 seconds, the shade will be automatically operated in sequence of slide open and slide close.
After the shade stops, release the switch 0.5 second later.
>> GO TO 2.
2.
STEP 2
1.
Operate sunshade switch and check that sunshade automatically operates normally.
2.
Perform anti-pinch function check. Refer to
>> INSPECTION END