Nissan Qashqai J11. Manual — part 1048
HA-18
< BASIC INSPECTION >
[TYPE 1]
DIAGNOSIS AND REPAIR WORKFLOW
BASIC INSPECTION
DIAGNOSIS AND REPAIR WORKFLOW
Work Flow
INFOID:0000000010451966
OVERALL SEQUENCE
DETAILED FLOW
1.
INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
NNIIA0143GB
DIAGNOSIS AND REPAIR WORKFLOW
HA-19
< BASIC INSPECTION >
[TYPE 1]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
>> GO TO 2.
2.
SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the inter-
viewed symptom.
Insufficient cooling/heating>>GO TO 3.
Refrigerant leakage>>GO TO 6.
Noise >> GO TO 7.
3.
CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system. Refer to
(AUTOMATIC AIR
CONDITIONING SYSTEM) or
(MANUAL AIR CONDITIONING SYSTEM),
(MANUAL HEATER).
Is A/C control system normal?
YES
>> GO TO 4.
NO
>> GO TO 8.
4.
PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Refer to
>> GO TO 5.
5.
TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify
the malfunctioning part. Refer to
.
Low refrigerant charge>>GO TO 6.
Except above>>GO TO 8.
6.
CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Refer to
.
>> GO TO 8.
7.
TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Refer to
>> GO TO 8.
8.
MALFUNCTION PART REPAIR
Repair or replace the malfunctioning part.
>> GO TO 9.
9.
REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES
>> INSPECTION END
NO
>> GO TO 2.
HA-20
< BASIC INSPECTION >
[TYPE 1]
REFRIGERANT
REFRIGERANT
Description
INFOID:0000000010451967
CONNECTION OF SERVICE TOOLS AND EQUIPMENT
Leak Test
INFOID:0000000010451968
CHECK REFRIGERANT LEAKAGE USING ELECTRICAL LEAK DETECTOR
WARNING:
Never check refrigerant leakage while the engine is running.
CAUTION:
Be careful of the following items so that inaccurate checks or misidentifications are avoided.
• Never allow refrigerant vapor, shop chemical vapors, cigarette smoke, or others around the vehicle.
• Always check refrigerant leakage in a low air flow environment so that refrigerant may not disperse
when leakage occurs.
1.
Stop the engine.
2.
Connect recovery/recycling/recharging equipment or manifold gauge set to A/C service valve.
3.
Check that A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or more when temperature
is 16
°
C (61
°
F) or more. When pressure is lower than the specified value, recycle refrigerant completely
and fill refrigerant to the specified level.
NOTE:
Leakages may not be detected if A/C refrigerant pressure is 345 kPa (3.45 bar, 3.52 kg/cm
2
, 50 psi) or
less when temperature is less than 16
°
C (61
°
F).
4.
Clean area where refrigerant leakage check is performed, and check refrigerant leakage along all sur-
faces of pipe connections and A/C system components using electrical leak detector probe.
CAUTION:
• Continue checking when a leakage is found. Always continue and complete checking along all
pipe connections and A/C system components for additional leakage.
• When a leakage is detected, clean leakage area using compressed air and check again.
• When checking leakage of cooling unit inside, always clean inside of drain hose so that the
probe surface may not be exposed to water or dirt.
NOTE:
1.
Shut-off valve
2.
A/C service valve
3.
Recovery/recycling recharging
equipment
4.
Vacuum pump
5.
Manifold gauge set
6.
Refrigerant container (HFO-1234yf)
7.
Weight scale
A.
Preferred (best) method
B.
Alternative method
C.
For charging
JSIIA0258ZZ
REFRIGERANT
HA-21
< BASIC INSPECTION >
[TYPE 1]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
• Always check leakage starting from high-pressure side and continue to low-pressure side.
• When checking leakage of cooling unit inside, operate blower fan motor for 15 minutes or more at the
maximum fan speed while the engine is stopped, and then insert electrical leak detector probe into drain
hose and hold for 10 minutes or more.
• When disconnecting shut-off valve that is connected to A/C service valve, always evacuate remaining
refrigerant so that misidentification can be avoided.
5.
Repair or replace parts where refrigerant leakage is detected. (Leakage is detected but leakage area is
unknown. GO TO 6.)
6.
Start the engine and set A/C control in the following conditions.
• A/C switch ON
• Air flow: VENT (ventilation)
• Intake door position: Recirculation
• Temperature setting: Full cold
• Fan speed: Maximum speed set
7.
Run the engine at approximately 1,500 rpm for 2 minutes or more.
8.
Stop the engine. Check again for refrigerant leakage. GO TO 4.
WARNING:
Never get burned when the engine is hot.
NOTE:
• Start refrigerant leakage check immediately after the engine is
stopped.
• When refrigerant circulation is stopped, pressure on the low-
pressure side rises gradually, and after this, pressure on the
high-pressure side falls gradually.
• The higher the pressure is, the easier it is to find the refriger-
ant leakage.
Recycle Refrigerant
INFOID:0000000010451969
WARNING:
• Always use HFO-1234yf for A/C refrigerant. If CFC-12 or HFC-134a is accidentally charged, compres-
sor is damaged due to insufficient lubrication.
• Always observe and follow precautions described on refrigerant container. Incorrect handling may
result in an explosion of refrigerant container, frostbite, or the loss of eyesight.
• Never breathe A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose, or
throat.
• Never allow HFO-1234yf to be exposed to an open flame or others because it generates poisonous
gas when in contact with high temperature objects. Keep workshop well ventilated.
1.
Perform lubricant return operation. Refer to
HA-23, "Perform Lubricant Return Operation"
. (If refrigerant or
lubricant leakage is detected in a large amount, omit this step, and then GO TO 2.)
CAUTION:
Never perform lubricant return operation if a large amount of refrigerant or lubricant leakage is
detected.
2.
Check gauge pressure readings of recovery/recycling/recharging equipment. When remaining pressure
exists, recycle refrigerant from high-pressure hose and low-pressure hose.
NOTE:
Follow manufacturer instructions for the handling or maintenance of the equipment. Never fill the equip-
ment with non-specified refrigerant.
3.
Remove A/C service valve cap from the vehicle.
4.
Connect recovery/recycling/recharging equipment to A/C service valve.
5.
Operate recovery/recycling/recharging equipment, and recycle refrigerant from the vehicle.
6.
Evacuate air for 10 minutes or more to remove any remaining refrigerant integrated to compressor lubri-
cant, etc.
7.
Refrigerant recycle operation is complete.
SHA839E