Nissan Qashqai J11. Manual — part 1047
HA-14
< PREPARATION >
[TYPE 1]
PREPARATION
Sealant or/and Lubricant
INFOID:0000000010451961
HFO-1234yf (R-1234yf) Service Tool and Equipment
• Never mix HFO-1234yf (R-1234yf) refrigerant and/or its specified lubricant with CFC-12 (R-12) and HFC-
134a (R-134a) refrigerant and/or its lubricant.
• Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
• Refrigerant container fittings, service hose fittings and service equipment fittings (equipment which handles
refrigerant and/or lubricant) are different between CFC-12 (R-12), HFC-134a (R-134a) and HFO-1234yf (R-
1234yf). This is to avoid mixed use of the refrigerants/lubricant.
• Never use adapters that convert one size fitting to another: refrigerant/lubricant contamination occurs and
compressor malfunction may result.
Service hoses
• High-pressure side hose
• Low-pressure side hose
• Utility hose
Hose fitting to gauge:
• 1/2
″
-16 ACME
Compliant with HFO-1234yf (R-1234yf)
Service couplers
• High-pressure side coupler
• Low-pressure side coupler
Hose fitting to service hose:
M14 x 1.5 fitting is optional or permanently
attached.
Compliant with HFO-1234yf (R-1234yf)
Refrigerant weight scale
For measuring of refrigerant
Fitting size: Thread size
1/2
″
-16 ACME
Compliant with HFO-1234yf (R-1234yf)
Vacuum pump
(Including the isolator valve)
Capacity:
• Air displacement: 4 CFM
• Micron rating: 20 microns
• Oil capacity: 482 g (17 oz.)
Fitting size: Thread size
• 1/2
″
-16 ACME
Compliant with HFO-1234yf (R-1234yf)
Tool name
Description
S-NT201
S-NT202
S-NT200
S-NT203
PREPARATION
HA-15
< PREPARATION >
[TYPE 1]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
Tool name
Description
HFO-1234yf (R-1234yf) refrigerant
Container color: Light blue
Container marking: HFO-1234yf (R-
1234yf)
Fitting size: Thread size
• Large container 1/2
″
-16 ACME
ND-OIL12
Type: Polyalkylene glycol oil (PAG)
Application:
HFO-1234yf (R-1234yf) swash plate
compressors
Capacity: 40 m
(1.4 Imp fl oz.)
S-NT196
JMIIA1759ZZ
HA-16
< SYSTEM DESCRIPTION >
[TYPE 1]
COMPONENT PARTS
SYSTEM DESCRIPTION
COMPONENT PARTS
Component Parts Location
INFOID:0000000010451962
Component Description
INFOID:0000000010451963
JMIIA3523ZZ
1.
Refrigerant pressure sensor
2.
Compressor
3.
Condenser
4.
Liquid tank
5.
Expansion valve
6.
Evaporator
A.
Built-in A/C unit assembly
Component
Description
Evaporator
The mist form liquid refrigerant transforms to gas by evaporation by the air conveyed from blower
motor. The air is cooled by the heat by evaporation.
Condenser
Cools refrigerant discharged from compressor, and transforms it to liquid refrigerant.
Compressor
Intakes, compresses, and discharges refrigerant, to circulate refrigerant inside the refrigerant cycle.
Refrigerant pressure sensor
HAC-19, "Refrigerant Pressure Sensor"
(AUTOMATIC AIR CONDITIONING SYSTEM) or
HAC-148, "Refrigerant Pressure Sensor"
(MANUAL AIR CINDITIONING SYSTEM).
Liquid tank
Eliminates foreign matter in refrigerant, and stores temporarily liquid refrigerant.
Expansion valve
Transforms high-pressure liquid refrigerant to mist form low-pressure liquid refrigerant by drawing
function.
SYSTEM
HA-17
< SYSTEM DESCRIPTION >
[TYPE 1]
C
D
E
F
G
H
J
K
L
M
A
B
HA
N
O
P
SYSTEM
System Diagram
INFOID:0000000010451964
System Description
INFOID:0000000010451965
REFRIGERANT CYCLE
Refrigerant Flow
The refrigerant from the compressor, flows the condenser with liquid tank, the evaporator, and returns to the
compressor. The refrigerant evaporation in the evaporator is controlled by an expansion valve.
Freeze Protection
When intake sensor detects that evaporator surface temperature is 2
°
C (36
°
F) or less, A/C auto amp. (Auto-
matic air conditioning) or A/C amp. (Manual air conditioning) requests ECM to turn the compressor OFF, and
ECM makes A/C relay to OFF, and stops the compressor.
REFRIGERANT SYSTEM PROTECTION
Refrigerant Pressure Sensor
• The refrigerant system is protected against excessively high- or low-pressures by the refrigerant pressure
sensor, installed at the high-pressure pipe 1. The refrigerant pressure sensor detects the pressure inside the
refrigerant line and sends the voltage signal to the ECM if the system pressure rises above, or falls below
the specifications.
• ECM turns the A/C relay to OFF and stops the compressor when the high-pressure side detected by refriger-
ant pressure sensor is following conditions;
- Approximately 3,120 kPa (31.2 bar, 31.8 kg/cm
2
, 452 psi) or more (Engine speed is less than 1,500 rpm.)
- Approximately 2,740 kPa (27.4 bar, 27.9 kg/cm
2
, 397 psi) or more (Engine speed is 1,500 rpm or more.)
- Approximately 140 kPa (1.4 bar, 1.4 kg/cm
2
, 20 psi) or less
Pressure Relief Valve
The refrigerant system is also protected by a pressure relief valve, located in the rear head of the compressor.
The release port on the pressure relief valve automatically opens and releases refrigerant into the atmosphere
when the pressure of refrigerant in the system increases to an unusual level [more than 3,800 kPa (38 bar,
38.8 kg/cm
2
, 551 psi)].
JMIIA3115GB