Nissan Primera P11. Manual — part 263
ECM Terminals and Reference Value
NCEC0250
Specification data are reference values and are measured between each terminal and 48 (ECM ground).
TERMI-
NAL
NO.
WIRE
COLOR
ITEM
CONDITION
DATA (DC Voltage)
14
P/B
EVAP canister purge
volume control solenoid
valve (ON/OFF duty)
[Engine is running]
I
Warm-up condition
I
Idle speed
BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
I
Warm-up condition
I
2,000 rpm
5 - 12V
SEF975W
On Board Diagnosis Logic
NCEC0251
DTC No.
Malfunction is detected when ...
Check Items (Possible Cause)
P0443
0443
I
An improper voltage signal is sent to ECM through the
valve.
I
Harness or connectors
(The valve circuit is open or shorted.)
I
EVAP canister purge volume control solenoid
valve
DTC Confirmation Procedure
NCEC0252
NOTE:
If “DTC Confirmation Procedure” has been previously conducted,
always turn ignition switch “OFF” and wait at least 9 seconds
before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery
voltage is more than 11V.
With CONSULT-II
1)
Turn ignition switch “ON”.
2)
Select “DATA MONITOR” mode with CONSULT-II.
3)
Start engine and let it idle for at least 5 seconds.
4)
If
1st
trip
DTC
is
detected,
go
to
“DIAGNOSTIC
PROCEDURE”, EC-SR-253.
With GST
1)
Start engine and let it idle for at least 5 seconds.
2)
Select “MODE 7” with GST.
3)
If
1st
trip
DTC
is
detected,
go
to
“DIAGNOSTIC
PROCEDURE”, EC-SR-253.
SEF058Y
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL
SOLENOID VALVE (CIRCUIT)
SR20DE
ECM Terminals and Reference Value
EC-251
Wiring Diagram
NCEC0253
YEC843
IGNITION SWITCH
ON or START
Refer to EL-POWER.
: Detectable line for DTC
: Non-detectable line for DTC
: Hyper CVT models
: M/T models
FUSE
BLOCK
(J/B)
EVAP
CANISTER
PURGE
CONTROL
SOLENOID
VALVE
.
ECM
REFER TO THE FOLLOWING
FUSE BLOCK -
Junction Box (J/B)
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL
SOLENOID VALVE (CIRCUIT)
SR20DE
Wiring Diagram
EC-252
Diagnostic Procedure
NCEC0254
1
CHECK POWER SUPPLY
1. Turn ignition switch “OFF”.
2. Disconnect EVAP canister purge volume control solenoid valve harness connector.
SEF219X
3. Turn ignition switch “ON”.
4. Check voltage between terminals 2 and engine ground with CONSULT-II or tester.
SEF077X
Voltage: Battery voltage
OK or NG
OK
©
GO TO 3.
NG
©
GO TO 2.
2
DETECT MALFUNCTIONING PART
Check the harness connectors M50, F104 (M81, F115 for CVT models).
©
Repair harness or connectors.
3
CHECK OUTPUT SIGNAL CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between
ECM terminal 14 and terminal 1.
Refer to wiring diagram.
Continuity should exist.
4. Also check harness for short to ground and short to power.
OK or NG
OK
©
GO TO 4.
NG
©
Repair open circuit or short to ground or short to power in harness or connectors.
Harness connector
EVAP canister purge
volume control solenoid
valve
Oil filler cap
DISCONNECT
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL
SOLENOID VALVE (CIRCUIT)
SR20DE
Diagnostic Procedure
EC-253
Component Inspection
NCEC0255
EVAP CANISTER PURGE VOLUME CONTROL
SOLENOID VALVE
NCEC0255S01
With CONSULT-II
1)
Start engine.
2)
Perform “PURG VOL CONT/V” in “ACTIVE TEST” mode with
CONSULT-II. Check that engine speed varies according to the
valve opening.
If OK, inspection end. If NG, go to following step.
3)
Check air passage continuity.
Condition
PURG VOL CONT/V value
Air passage continuity
between A and B
100.0%
Yes
0.0%
No
If NG, replace the EVAP canister purge volume control sole-
noid valve.
Without CONSULT-II
Check air passage continuity.
Condition
Air passage continuity
between A and B
12V direct current supply between ter-
minals
Yes
No supply
No
If NG or operation takes more than 1 second, replace solenoid
valve.
4
CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to “Component Inspection” EC-SR-254.
OK or NG
OK
©
GO TO 5.
NG
©
Replace EVAP canister purge volume control solenoid valve.
5
CHECK INTERMITTENT INCIDENT
Perform “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-SR-114.
©
INSPECTION END
NEF111A
SEF079X
DTC P0443 EVAP CANISTER PURGE VOLUME CONTROL
SOLENOID VALVE (CIRCUIT)
SR20DE
Component Inspection