Nissan Pathfinder. Manual — part 347
DLK-154
< DTC/CIRCUIT DIAGNOSIS >
B2623 INSIDE ANTENNA
2.
CHECK INSIDE KEY ANTENNA CIRCUIT
1. Disconnect BCM connector and inside key antenna (luggage room) connector.
2. Check continuity between BCM harness connector and inside key antenna (luggage room) harness con-
nector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK INSIDE KEY ANTENNA INPUT SIGNAL 2
1. Replace inside key antenna (luggage room). (New antenna or other antenna)
2. Connect BCM connector and inside key antenna (luggage room) connector.
3. Check signal between BCM harness connector and ground using oscilloscope.
Is the inspection result normal?
YES
>> Replace inside key antenna (luggage room). Refer to
DLK-315, "LUGGAGE ROOM : Removal
.
NO
>> Replace BCM. Refer to
BCS-80, "Removal and Installation"
BCM
Inside key antenna (luggage room)
Continuity
Connector
Terminal
Connector
Terminal
M20
100
B76
1
Yes
99
2
BCM
Ground
Continuity
Connector
Terminal
M20
100
No
99
(+)
(–)
Condition
Signal
(Reference value)
BCM
Connector
Terminal
M20
100, 99
Ground
When Intelligent Key is in the an-
tenna detection area
When Intelligent Key is not in the
antenna detection area
JMKIA3839GB
JMKIA5951GB
B26FD SHIFT LOCK SOLENOID
DLK-155
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
B26FD SHIFT LOCK SOLENOID
DTC Logic
INFOID:0000000009175694
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.
PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check “Self Diagnostic Result” mode of “BCM” using CONSULT.
Is DTC detected?
YES
>> Refer to
DLK-155, "Diagnosis Procedure"
NO
>> Shift lock solenoid is OK.
Diagnosis Procedure
INFOID:0000000009175695
Regarding Wiring Diagram information, refer to
1.
CHECK POWER SOURCE (STOP LAMP SWITCH)
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch connector.
3. Check voltage between stop lamp switch connector E38 terminal 1 and ground.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Check the following:
• Harness for short or open between fuse block (J/B) and stop lamp switch
• 10A fuse (No. 10, located in fuse block [J/B])
2.
CHECK STOP LAMP SWITCH
Check stop lamp switch. Refer to
TM-179, "Component Inspection (Stop Lamp Switch)"
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Replace stop lamp switch. Refer to
.
3.
CHECK GROUND CIRCUIT (STOP LAMP RELAY)
1. Remove the stop lamp relay.
2. Check continuity between stop lamp relay connector E39 terminal 2 and ground.
DTC
CONSULT display
description
DTC detecting condition
Possible cause
B26FD
SHIFT LOCK SOLE-
NOID
BCM shift lock solenoid output control is OFF but
shift lock solenoid output feedback is ON.
• Shift lock solenoid
• Harness or connector
• Shift lock solenoid circuit is open or
shorted
Stop lamp switch
Ground
Voltage
Connector
Terminal
E38
1
Battery voltage
Stop lamp relay
Ground
Continuity
Connector
Terminal (+)
E39
2
Yes
DLK-156
< DTC/CIRCUIT DIAGNOSIS >
B26FD SHIFT LOCK SOLENOID
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace damaged parts.
4.
CHECK HARNESS BETWEEN STOP LAMP RELAY AND BCM
1. Disconnect BCM connector M18. Check continuity between stop lamp relay connector E39 terminal 5 and
BCM connector M18 terminal 27.
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Repair or replace damaged parts.
5.
CHECK HARNESS BETWEEN STOP LAMP SWITCH AND STOP LAMP RELAY
Check continuity between stop lamp relay connector E39 terminal 2 and stop lamp switch connector E38 ter-
minal 1.
Is the inspection result normal?
YES
>> GO TO 6.
NO
>> Repair or replace damaged parts.
6.
CHECK POWER SOURCE (STOP LAMP RELAY)
Check voltage between stop lamp relay connector E39 terminal 3 and ground.
Is the inspection result normal?
YES
>> GO TO 7.
NO
>> Repair or replace damaged parts.
7.
CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR OPEN
1. Disconnect CVT shift selector connector and BCM connector M80.
2. Check continuity between BCM connector M80 terminal 108 and CVT shift selector connector M78 termi-
nal 3.
Is the inspection result normal?
YES
>> GO TO 8.
NO
>> Repair or replace damaged parts.
8.
CHECK HARNESS BETWEEN BCM AND CVT SHIFT SELECTOR FOR SHORT CIRCUIT
Check continuity between BCM connector M80 terminal 108 and ground.
BCM
stop lamp relay
Continuity
Connector
Terminal
Connector
Terminal
M18
27
E39 5
Yes
Stop lamp switch
Stop lamp relay
Continuity
Connector
Terminal
Connector
Terminal
E38
2
E39 1
Yes
Stop lamp relay
Ground
Continuity
Connector
Terminal (+)
E39
3
Battery voltage
BCM
CVT shift selector
Continuity
Connector
Terminal
Connector
Terminal
M80
108
M78
3
Yes
B26FD SHIFT LOCK SOLENOID
DLK-157
< DTC/CIRCUIT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> GO TO 9.
NO
>> Repair or replace damaged parts.
9.
CHECK GROUND CIRCUIT (CVT SHIFT SELECTOR)
Check continuity between CVT shift selector connector M78 terminal 4 and ground.
Is the inspection result normal?
YES
>> Replace CVT shift selector. Refer to
TM-189, "Removal and Installation"
NO
>> Repair or replace damaged parts.
BCM
Ground
Continuity
Connector
Terminal
M80
108
No
CVT shift selector
Ground
Continuity
Connector
Terminal
M78
4
Yes
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.