Nissan Titan. Manual — part 247
P0442 EVAP CONTROL SYSTEM
EC-289
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
P0442 EVAP CONTROL SYSTEM
On Board Diagnosis Logic
INFOID:0000000009886698
This diagnosis detects leaks in the EVAP purge line using engine intake manifold vacuum.
If pressure does not increase, the ECM will check for leaks in the line between the fuel tank and EVAP canister
purge volume control solenoid valve, under the following “Vacuum test” conditions.
The EVAP canister vent control valve is closed to shut the EVAP purge line off. The EVAP canister purge vol-
ume control solenoid valve will then be opened to depressurize the EVAP purge line using intake manifold
vacuum. After this occurs, the EVAP canister purge volume control solenoid valve will be closed.
CAUTION:
• Use only a genuine NISSAN fuel filler cap as a replacement. If an incorrect fuel filler cap is used, the
MIL may come on.
• If the fuel filler cap is not tightened properly, the MIL may come on.
• Use only a genuine NISSAN rubber tube as a replacement.
DTC No.
Trouble diagnosis name
DTC detecting condition
Possible cause
P0442
0442
EVAP control system
small leak detected
(negative pressure)
EVAP control system has a leak, EVAP
control system does not operate prop-
erly.
• Incorrect fuel tank vacuum relief valve
• Incorrect fuel filler cap used
• Fuel filler cap remains open or fails to close.
• Foreign matter caught in fuel filler cap.
• Leak is in line between intake manifold and EVAP
canister purge volume control solenoid valve.
• Foreign matter caught in EVAP canister vent con-
trol valve.
• EVAP canister or fuel tank leaks
• EVAP purge line (pipe and rubber tube) leaks
• EVAP purge line rubber tube bent
• Loose or disconnected rubber tube
• EVAP canister vent control valve and the circuit
• EVAP canister purge volume control solenoid
valve and the circuit
• Fuel tank temperature sensor
• Drain filter
• O-ring of EVAP canister vent control valve is
missing or damaged
• EVAP canister is saturated with water
• EVAP control system pressure sensor
• Fuel level sensor and the circuit
• Refueling EVAP vapor cut valve
• ORVR system leaks
PBIB3640E
EC-290
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0442 EVAP CONTROL SYSTEM
DTC Confirmation Procedure
INFOID:0000000009886699
NOTE:
• If DTC Confirmation Procedure has been previously conducted, always perform the following before con-
ducting the next step.
1. Turn ignition swich OFF and wait at least 10 seconds.
2. Turn ignition swich ON.
3. Turn ignition swich OFF and wait at least 10 seconds.
TESTING CONDITION:
• Perform “DTC WORK SUPPORT” when the fuel level is between 1/4 and 3/4 full, and vehicle is placed
on flat level surface.
• Always perform test at a temperature of 0 to 30
°C (32 to 86°F).
WITH CONSULT
1. Turn ignition switch ON.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT.
4. Make sure that the following conditions are met.
COOLAN TEMP/S: 0 - 70
°C (32 - 158°F)
INT/A TEMP SE: 0 - 30
°C (32 - 86°F)
5. Select “EVP V/S LEAK P0456/P1456” of “EVAPORATIVE SYSTEM” in “DTC WORK SUPPORT” mode
with CONSULT.
Follow the instruction displayed.
NOTE:
If the engine speed cannot be maintained within the range displayed on the CONSULT screen, go to
.
6. Make sure that “OK” is displayed.
If “NG” is displayed, refer to
.
NOTE:
Make sure that EVAP hoses are connected to EVAP canister purge volume control solenoid valve
properly.
WITH GST
NOTE:
Be sure to read the explanation of
before driving vehicle.
1. Start engine.
2. Drive vehicle according to
3. Stop vehicle.
4. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
5. Select Service $07 with GST.
-
If P0442 is displayed on the screen, go to
.
-
If P0441 is displayed on the screen, go to
.
Diagnosis Procedure
INFOID:0000000009886700
1.
CHECK FUEL FILLER CAP DESIGN
1. Turn ignition switch OFF.
2. Check for genuine NISSAN fuel filler cap design.
OK or NG
OK
>> GO TO 2.
NG
>> Replace with genuine NISSAN fuel filler cap.
SEF915U
P0442 EVAP CONTROL SYSTEM
EC-291
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
2.
CHECK FUEL FILLER CAP INSTALLATION
Check that the cap is tightened properly by rotating the cap clockwise.
OK or NG
OK
>> GO TO 3.
NG
>> 1. Open fuel filler cap, then clean cap and fuel filler neck threads using air blower.
2. Retighten until ratcheting sound is heard.
3.
CHECK FUEL FILLER CAP FUNCTION
Check for air releasing sound while opening the fuel filler cap.
OK or NG
OK
>> GO TO 5.
NG
>> GO TO 4.
4.
CHECK FUEL TANK VACUUM RELIEF VALVE
EC-295, "Component Inspection"
OK or NG
OK
>> GO TO 5.
NG
>> Replace fuel filler cap with a genuine one.
5.
INSTALL THE PRESSURE PUMP
To locate the EVAP leak, install EVAP service port adapter (commer-
cial service tool) and pressure pump to EVAP service port securely.
NOTE:
Improper installation of the EVAP service port adapter to the
EVAP service port may cause leaking.
With CONSULT>>GO TO 6.
Without CONSULT>>GO TO 7.
6.
CHECK FOR EVAP LEAK
With CONSULT
1. Turn ignition switch ON.
2. Select “EVAP SYSTEM CLOSE” of “WORK SUPPORT” mode with CONSULT.
3. Touch “START” and apply pressure into the EVAP line until the pressure indicator reaches the middle of
the bar graph.
CAUTION:
• Never use compressed air or a high pressure pump.
• Do not exceed 4.12 kPa (0.042 kg/cm
2
, 0.6 psi) of pressure in the system.
BBIA0366E
SEF916U
EC-292
< DTC/CIRCUIT DIAGNOSIS >
[VK56DE]
P0442 EVAP CONTROL SYSTEM
4. Using EVAP leak detector, locate the EVAP leak. For the leak
detector, refer to the instruction manual for more details.
.
OK or NG
OK
>> GO TO 8.
NG
>> Repair or replace.
7.
CHECK FOR EVAP LEAK
Without CONSULT
1. Turn ignition switch OFF.
2. Apply 12 volts DC to EVAP canister vent control valve (4). The
valve will close. (Continue to apply 12 volts until the end of test.)
3. Pressurize the EVAP line using pressure pump with 1.3 to 2.7
kPa (10 to 20 mmHg, 0.39 to 0.79 inHg), then remove pump and
EVAP service port adapter.
CAUTION:
• Never use compressed air or a high pressure pump.
• Do not exceed 4.12 kPa (0.042 kg/cm
2
, 0.6 psi) of pressure
in the system.
4. Using EVAP leak detector, locate the EVAP leak. For the leak
detector, refer to the instruction manual for more details. Refer
.
OK or NG
OK
>> GO TO 8.
NG
>> Repair or replace.
8.
CHECK DRAIN FILTER
EC-295, "Component Inspection"
OK or NG
OK
>> GO TO 9.
NG
>> Replace drain filter.
9.
CHECK EVAP CANISTER VENT CONTROL VALVE
Check the following.
• EVAP canister vent control valve is installed properly.
FL-16, "Removal and Installation"
• EVAP canister vent control valve.
EC-306, "Component Inspection"
.
OK or NG
OK
>> GO TO 10.
NG
>> Repair or replace EVAP canister vent control valve and O-ring.
10.
CHECK IF EVAP CANISTER SATURATED WITH WATER
SEF200U
1
: Drain filter
2
: EVAP control system pressure sensor
3
: EVAP canister
ALBIA0401ZZ
SEF200U