Nissan Frontier D40. Manual — part 910
PWC-22
< COMPONENT DIAGNOSIS >
POWER WINDOW MOTOR
1.
Disconnect front power window motor RH.
2.
Turn ignition switch ON.
3.
Check voltage between front power window motor RH connector
and ground.
Is the measurement value within the specification?
YES
>> GO TO 2
NO
>> Replace power window and door lock/unlock switch RH. Refer to
PWC-66, "Removal and Installa-
.
2.
CHECK HARNESS CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect power window and door lock/unlock switch RH.
3.
Check continuity between power window and door lock/unlock
switch RH connector and front power window motor RH connec-
tor.
4.
Check continuity between power window and door lock/unlock switch RH connector and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK FRONT POWER WINDOW MOTOR RH
Check front power window motor RH.
Refer to
PWC-22, "PASSENGER SIDE : Component Inspection"
.
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-46, "Intermittent Incident"
.
NO
>> Replace front power window motor RH. Refer to
GW-16, "Front Door Glass Regulator"
.
PASSENGER SIDE : Component Inspection
INFOID:0000000005274627
COMPONENT INSPECTION
1.
CHECK FRONT POWER WINDOW MOTOR RH
Does motor operate by connecting the battery voltage directly to front power window motor RH?
Terminal
Front power
window motor
RH condition
Voltage (V)
(Approx.)
(+)
(–)
Front power window
motor RH connector
Terminal
D104
2
Ground
UP
Battery voltage
DOWN
0
1
UP
0
DOWN
Battery voltage
PIIB6431E
Power window and
door lock/unlock
switch RH connector
Terminal
Front power window
motor RH connector
Terminal
Continuity
D105
6
D104
1
Yes
7
2
Power window and door
lock/unlock switch RH con-
nector
Terminal
Ground
Continuity
D105
6
No
7
LIIA2057E
POWER WINDOW MOTOR
PWC-23
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
Is the inspection result normal?
YES
>> Front power window motor RH is OK.
NO
>> Replace front power window motor RH. Refer to
GW-16, "Front Door Glass Regulator"
.
REAR LH
REAR LH : Description
INFOID:0000000005274628
Door glass moves UP/DOWN by receiving the signal from power window main switch or rear power window
switch LH.
REAR LH : Component Function Check
INFOID:0000000005274629
1.
CHECK REAR POWER WINDOW MOTOR LH CIRCUIT
Does rear power window motor LH operate with main power window and door lock/unlock switch or rear
power window switch LH?
Is the inspection result normal?
YES
>> Rear power window motor LH is OK.
NO
>> Refer to
PWC-23, "REAR LH : Diagnosis Procedure"
.
REAR LH : Diagnosis Procedure
INFOID:0000000005274630
Regarding Wiring Diagram information, refer to
.
1.
CHECK REAR POWER WINDOW SWITCH OUTPUT SIGNAL
1.
Disconnect rear power window motor LH.
2.
Turn ignition switch ON.
3.
Check voltage between rear power window motor LH connector
and ground.
Is the measurement value within the specification?
YES
>> GO TO 2
NO
>> Check rear power window switch LH. Refer to
PWC-17, "REAR POWER WINDOW SWITCH :
.
2.
CHECK HARNESS CONTINUITY
Terminal
Motor condition
(+)
(–)
1
2
DOWN
2
1
UP
Terminal
Window
condition
Voltage (V)
(Approx.)
(+)
(–)
Rear power window
motor LH connector
Terminal
D204
1
Ground
UP
Battery voltage
DOWN
0
2
UP
0
DOWN
Battery voltage
LIIA2228E
PWC-24
< COMPONENT DIAGNOSIS >
POWER WINDOW MOTOR
1.
Turn ignition switch OFF.
2.
Disconnect rear power window switch LH.
3.
Check continuity between rear power window switch LH connec-
tor (A) and rear power window motor LH connector (B).
4.
Check continuity between rear power window switch LH connec-
tor (A) and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK REAR POWER WINDOW MOTOR LH
Check rear power window motor LH.
Refer to
PWC-24, "REAR LH : Component Inspection"
Is the inspection result normal?
YES
>> Check intermittent incident. Refer to
GI-46, "Intermittent Incident"
.
NO
>> Replace rear power window motor LH. Refer to
GW-20, "Rear Door Glass Regulator"
REAR LH : Component Inspection
INFOID:0000000005274631
COMPONENT INSPECTION
1.
CHECK REAR POWER WINDOW MOTOR LH
Does motor operate by connecting the battery voltage directly to rear power window motor LH?
Is the inspection result normal?
YES
>> Rear power window motor LH is OK.
NO
>> Replace rear power window motor LH. Refer to
GW-20, "Rear Door Glass Regulator"
REAR RH
REAR RH : Description
INFOID:0000000005274632
Door glass moves UP/DOWN by receiving the signal from main power window and door lock/unlock switch or
rear power window switch RH.
REAR RH : Component Function Check
INFOID:0000000005274633
1.
CHECK REAR POWER WINDOW MOTOR RH CIRCUIT
Does rear power window motor RH operate with operating main power window and door lock/unlock switch or
rear power window switch RH?
Is the inspection result normal?
Rear power window
switch LH connector
Terminal
Rear power window
motor LH connector
Terminal
Continuity
D203 (A)
6
D204 (B)
1
Yes
7
2
Rear power window switch
LH connector
Terminal
Ground
Continuity
D203 (A)
6
No
7
LIIA2229E
Terminal
Motor condition
(+)
(–)
2
1
DOWN
1
2
UP
POWER WINDOW MOTOR
PWC-25
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
YES
>> Rear power window motor RH is OK.
NO
>> Refer to
PWC-25, "REAR RH : Diagnosis Procedure"
.
REAR RH : Diagnosis Procedure
INFOID:0000000005274634
Regarding Wiring Diagram information, refer to
.
1.
CHECK REAR POWER WINDOW SWITCH RH OUTPUT SIGNAL
1.
Disconnect rear power window motor RH.
2.
Turn ignition switch ON.
3.
Check voltage between rear power window motor RH connector
and ground.
Is the measurement value within the specification?
YES
>> GO TO 2
NO
>> Check rear power window switch RH. Refer to
PWC-17, "REAR POWER WINDOW SWITCH :
.
2.
CHECK HARNESS CONTINUITY
1.
Turn ignition switch OFF.
2.
Disconnect rear power window switch RH.
3.
Check continuity between rear power window switch RH con-
nector (A) and rear power window motor RH connector (B).
4.
Check continuity between rear power window switch RH con-
nector (A) and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
>> Repair or replace harness.
3.
CHECK REAR POWER WINDOW MOTOR RH
Check rear power window motor RH.
Refer to
PWC-26, "REAR RH : Component Inspection"
.
Is the inspection result normal?
Terminal
Rear power
window switch
RH condition
Voltage (V)
(Approx.)
(+)
(–)
Rear power window
motor RH connector
Terminal
D304
1
Ground
UP
Battery voltage
DOWN
0
2
UP
0
DOWN
Battery voltage
LIIA2228E
Rear power window
switch RH connector
Terminal
Rear power window
motor RH connector
Terminal
Continuity
D303 (A)
6
D304 (B)
1
Yes
7
2
Rear power window switch
RH connector
Terminal
Ground
Continuity
D303 (A)
6
No
7
LIIA2229E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.