Nissan Frontier D40. Manual — part 911
PWC-26
< COMPONENT DIAGNOSIS >
POWER WINDOW MOTOR
YES
>> Check intermittent incident. Refer to
GI-46, "Intermittent Incident"
.
NO
>> Replace rear power window motor RH. Refer to
GW-20, "Rear Door Glass Regulator"
.
REAR RH : Component Inspection
INFOID:0000000005274635
COMPONENT INSPECTION
1.
CHECK REAR POWER WINDOW MOTOR RH
Does motor operate by connecting the battery voltage directly to rear power window motor RH?
Is the inspection result normal?
YES
>> Rear power window motor RH is OK.
NO
>> Replace rear power window motor RH. Refer to
GW-20, "Rear Door Glass Regulator"
.
Terminal
Motor condition
(+)
(–)
2
1
DOWN
1
2
UP
DOOR SWITCH
PWC-27
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
DOOR SWITCH
KING CAB
KING CAB : Description
INFOID:0000000005274636
Detects door open/close condition.
KING CAB : Component Function Check
INFOID:0000000005274637
1.
CHECK FUNCTION
With CONSULT-III
Check door switches in data monitor mode with CONSULT-III.
Is the inspection result normal?
YES
>> Door switch is OK.
NO
>> Refer to
PWC-27, "KING CAB : Diagnosis Procedure"
.
KING CAB : Diagnosis Procedure
INFOID:0000000005274638
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-III
Check door switches ("DOOR SW-DR", "DOOR SW-AS") in DATA MONITOR mode with CONSULT–III. Refer
to
BCS-15, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)"
• When any doors are open:
• When any doors are closed:
Without CONSULT-III
Check voltage between BCM connector M18 or M19 terminals 12,
47 and ground.
Is the inspection result normal?
YES
>> Door switch circuit is OK.
NO
>> GO TO 2
Monitor item
Condition
DOOR SW-DR
CLOSE
→
OPEN: OFF
→
ON
DOOR SW-AS
DOOR SW-DR
:ON
DOOR SW-AS
:ON
DOOR SW-DR
:OFF
DOOR SW-AS
:OFF
Connec-
tor
Item
Terminals
Condition
Voltage (V)
(Approx.)
(+)
(–)
M19
Front door
switch LH
47
Ground
Open
↓
Closed
0
↓
Battery voltage
M18
Front door
switch RH
12
LIIA1174E
PWC-28
< COMPONENT DIAGNOSIS >
DOOR SWITCH
2.
CHECK BCM OUTPUT VOLTAGE
1.
Turn ignition switch OFF.
2.
Disconnect door switches.
3.
Check voltage between BCM connector M18, M19 terminals 12,
47 and ground.
Is the inspection result normal?
YES
>> GO TO 3
NO
BCS-54, "Removal and Installa-
.
3.
CHECK DOOR SWITCH CIRCUIT
1.
Disconnect BCM.
2.
Check continuity between door switch connector D213 (Front
LH), D314 (Front RH) terminal 2 and BCM connector M18, M19
terminals 12, and 47.
3.
Check continuity between door switch connector D213 (Front
LH), D314 (Front RH) terminal 2 and ground.
Is the inspection result normal?
YES
>> GO TO 4
NO
>> Repair or replace harness.
4.
CHECK DOOR SWITCHES GROUND CIRCUIT
Check continuity between door switch connector D213 (Front LH),
D314 (Front RH) terminal 3 and ground.
Is the inspection result normal?
YES
>> GO TO 5
NO
>> Repair or replace harness.
5.
CHECK DOOR SWITCHES
Check continuity between door switch terminals.
Is the inspection result normal?
YES
>> Check condition of harness and connector.
NO
>> Replace door switch.
CREW CAB
12 - Ground
: Battery voltage
47 - Ground
: Battery voltage
LIIA1174E
2 - 47
: Continuity should exist
2 - 12
: Continuity should exist
2 - Ground
: Continuity should not exist
LIIA0947E
3 - Ground
: Continuity should not exist
ALKIA1848ZZ
Item
Terminal
Condition
Continuity
Door switches
(front)
2 – 3
Open
Yes
Closed
No
ALKIA1849ZZ
DOOR SWITCH
PWC-29
< COMPONENT DIAGNOSIS >
C
D
E
F
G
H
I
J
L
M
A
B
PWC
N
O
P
CREW CAB : Description
INFOID:0000000005274639
Detects door open/close condition.
CREW CAB : Component Function Check
INFOID:0000000005274640
1.
CHECK FUNCTION
With CONSULT-III
Check door switches in data monitor mode with CONSULT-III.
Is the inspection result normal?
YES
>> Door switch is OK.
NO
>> Refer to
PWC-29, "CREW CAB : Diagnosis Procedure"
.
CREW CAB : Diagnosis Procedure
INFOID:0000000005274641
Regarding Wiring Diagram information, refer to
.
1.
CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-III
Check door switches ("DOOR SW-DR", "DOOR SW-AS") in DATA MONITOR mode with CONSULT–III. Refer
to
BCS-15, "DOOR LOCK : CONSULT-III Function (BCM - DOOR LOCK)"
• When any doors are open:
• When any doors are closed:
Without CONSULT-III
Check voltage between BCM connector M18 or M19 terminals 12,
47 and ground.
Is the inspection result normal?
YES
>> Door switch circuit is OK.
NO
>> GO TO 2
2.
CHECK BCM OUTPUT VOLTAGE
Monitor item
Condition
DOOR SW-DR
CLOSE
→
OPEN: OFF
→
ON
DOOR SW-AS
DOOR SW-DR
: ON
DOOR SW-AS
: ON
DOOR SW-DR
: OFF
DOOR SW-AS
: OFF
Connec-
tor
Item
Terminals
Condition
Voltage (V)
(Approx.)
(+)
(–)
M19
Front door
switch LH
47
Ground
Open
↓
Closed
0
↓
Battery voltage
M18
Front door
switch RH
12
LIIA0946E
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.