Nissan Frontier D40. Manual — part 463
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
EC-543
< COMPONENT DIAGNOSIS >
[VQ40DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
OK
>> INSPECTION END
NG
>> GO TO 15.
15.
DISCONNECT AND RECONNECT ECM HARNESS CONNECTOR
1.
Stop the engine.
2.
Disconnect ECM harness connector. Check pin terminal and connector for damage, and then reconnect it.
>> GO TO 16.
16.
CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”
1.
Start engine.
2.
Select “A/F ALPHA-B1”, “A/F ALPHA-B2” in “SPEC” of “DATA MONITOR” mode, and make sure that
each indication is within the SP value.
OK or NG
OK
>> INSPECTION END
NG
>> Detect malfunctioning part according to
EC-943, "Symptom Matrix Chart"
17.
CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and make sure that the indication is within the
SP value.
OK or NG
OK
>> INSPECTION END
NG (More than the SP value)>>GO TO 18.
NG (Less than the SP value)>>GO TO 25.
18.
DETECT MALFUNCTIONING PART
1.
Check for the cause of large engine friction. Refer to the following.
-
Engine oil level is too high
-
Engine oil viscosity
-
Belt tension of power steering, alternator, A/C compressor, etc. is excessive
-
Noise from engine
-
Noise from transmission, etc.
2.
Check for the cause of insufficient combustion. Refer to the following.
-
Valve clearance malfunction
-
Intake valve timing control function malfunction
-
Camshaft sprocket installation malfunction, etc.
>> Repair or replace malfunctioning part, and then GO TO 30.
19.
CHECK INTAKE SYSTEM
Check for the cause of uneven air flow through mass air flow sensor. Refer to the following.
• Crushed air ducts
• Malfunctioning seal of air cleaner element
• Uneven dirt of air cleaner element
• Improper specification of intake air system
OK or NG
OK
>> GO TO 21.
NG
>> Repair or replace malfunctioning part, and then GO TO 20.
20.
CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”, AND “B/FUEL SCHDL”
Select “A/F ALPHA-B1”, “A/F ALPHA-B2”, and “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and
make sure that each indication is within the SP value.
OK or NG
OK
>> INSPECTION END
NG (“B/FUEL SCHDL” is more, “A/F ALPHA-B1”, “A/F ALPHA-B2” are less than the SP value)>>GO TO 21.
21.
DISCONNECT AND RECONNECT MASS AIR FLOW SENSOR HARNESS CONNECTOR
1.
Stop the engine.
EC-544
< COMPONENT DIAGNOSIS >
[VQ40DE]
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
2.
Disconnect mass air flow sensor harness connector. Check pin terminal and connector for damage and
then reconnect it again.
>> GO TO 22.
22.
CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”
1.
Start engine.
2.
Select “A/F ALPHA-B1”, “A/F ALPHA-B2” in “SPEC” of “DATA MONITOR” mode, and make sure that
each indication is within the SP value.
OK or NG
OK
>> 1.
Detect malfunctioning part of mass air flow sensor circuit and repair it. Refer to
2.
GO TO 29.
NG
>> GO TO 23.
23.
CHECK “MAS A/F SE-B1”
Select “MAS A/F SE-B1” in “SPEC” of “DATA MONITOR” mode, and make sure that the indication is within the
SP value.
OK or NG
OK
>> GO TO 24.
NG (More than the SP value)>>Replace mass air flow sensor, and then GO TO 29.
24.
REPLACE ECM
1.
Replace ECM.
2.
Perform initialization of NVIS(NATS) system and registration of all NVIS(NATS) ignition key IDs. Refer to
SEC-7, "ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement"
.
3.
4.
EC-473, "Accelerator Pedal Released Position Learning"
5.
EC-473, "Throttle Valve Closed Position Learning"
6.
EC-473, "Idle Air Volume Learning"
.
>> GO TO 29.
25.
CHECK INTAKE SYSTEM
Check for the cause of uneven air flow through mass air flow sensor. Refer to the following.
• Crushed air ducts
• Malfunctioning seal in air cleaner element
• Uneven dirt in air cleaner element
• Improper specification in intake air system
OK or NG
OK
>> GO TO 27.
NG
>> Repair or replace malfunctioning part, and then GO TO 26.
26.
CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and make sure that the indication is within the
SP value.
OK or NG
OK
>> INSPECTION END
NG (Less than the SP value)>>GO TO 27.
27.
CHECK “MAS A/F SE-B1”
Select “MAS A/F SE-B1” in “SPEC” of “DATA MONITOR” mode, and make sure that the indication is within the
SP value.
OK or NG
OK
>> GO TO 28.
NG (Less than the SP value)>>Replace mass air flow sensor, and then GO TO 30.
28.
CHECK INTAKE SYSTEM
Check for the cause of air leak after the mass air flow sensor. Refer to the following.
TROUBLE DIAGNOSIS - SPECIFICATION VALUE
EC-545
< COMPONENT DIAGNOSIS >
[VQ40DE]
C
D
E
F
G
H
I
J
K
L
M
A
EC
N
P
O
• Disconnection, looseness, and cracks in air duct
• Looseness of oil filler cap
• Disconnection of oil level gauge
• Open stuck, breakage, hose disconnection, or cracks of PCV valve
• Disconnection or cracks in EVAP purge hose, stick open canister purge volume control solenoid valve
• Malfunctioning seal in rocker cover gasket
• Disconnection, looseness, or cracks in hoses, such as a vacuum hose, connecting to intake air system parts
• Malfunctioning seal in intake air system, etc.
>> GO TO 30.
29.
CHECK “A/F ALPHA-B1”, “A/F ALPHA-B2”, AND “B/FUEL SCHDL”
Select “A/F ALPHA-B1”, “A/F ALPHA-B2”, and “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and
make sure that each indication is within the SP value.
OK or NG
OK
>> INSPECTION END
NG
>> Detect malfunctioning part according to
EC-943, "Symptom Matrix Chart"
30.
CHECK “B/FUEL SCHDL”
Select “B/FUEL SCHDL” in “SPEC” of “DATA MONITOR” mode, and then make sure that the indication is
within the SP value.
OK or NG
OK
>> INSPECTION END
NG
>> Detect malfunctioning part according to
EC-546
< COMPONENT DIAGNOSIS >
[VQ40DE]
POWER SUPPLY AND GROUND CIRCUIT
POWER SUPPLY AND GROUND CIRCUIT
Diagnosis Procedure
INFOID:0000000005273496
1.
INSPECTION START
Start engine.
Is engine running?
Yes or No
Yes
>> GO TO 8.
No
>> GO TO 2.
2.
CHECK ECM POWER SUPPLY CIRCUIT-I
1.
Turn ignition switch OFF and then ON.
2.
Check voltage between ECM terminal 109 and ground with
CONSULT-III or tester.
OK or NG
OK
>> GO TO 4.
NG
>> GO TO 3.
3.
DETECT MALFUNCTIONING PART
Check the following.
• Fuse block (J/B) connector M4
• Harness connectors M31, E152
• 10A fuse (No.1)
• Harness for open or short between ECM and fuse
>> Repair harness or connectors.
4.
CHECK GROUND CONNECTIONS
1.
Turn ignition switch OFF.
2.
Loosen and retighten three ground screws on the body. Refer to
OK or NG
OK
>> GO TO 5.
NG
>> Repair or replace ground connections.
5.
CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
1.
Disconnect ECM harness connector.
2.
Check harness continuity between ECM terminals 1, 115, 116 and ground.
Refer to Wiring Diagram.
Voltage: Battery voltage
MBIB0015E
BBIA0539E
Continuity should exist.
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.