Nissan Juke F15. Manual — part 1022
PCS-32
< DTC/CIRCUIT DIAGNOSIS >
[IPDM E/R]
B2098 IGNITION RELAY ON STUCK
B2098 IGNITION RELAY ON STUCK
Description
INFOID:0000000012197167
• IPDM E/R operates the ignition relay when it receives an ignition switch ON signal from BCM via CAN com-
munication.
• Turn the ignition relay OFF by pressing the push-button ignition switch once when the vehicle speed is 4 km/
h (2.5 MPH) or less.
• Turn the ignition relay OFF with the following operation when the vehicle speed is more than 4 km/h (2.5
MPH) or when an abnormal condition occurs in CAN communication from the combination meter (Emer-
gency OFF)
- Press and hold the push-button ignition switch for 2 seconds or more.
- Press the push-button ignition switch 3 times within 1.5 seconds.
NOTE:
The ignition relay does not turn ON for 3 seconds after emergency OFF even if the push-button ignition switch
is pressed.
DTC Logic
INFOID:0000000012197168
DTC DETECTION LOGIC
1.
PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check DTC in “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
Is DTC detected?
YES
>> Refer to
.
NO
>> INSPECTION END.
Diagnosis Procedure
INFOID:0000000012197169
1.
CHECK SELF DIAGNOSTIC RESULT
Check DTC using CONSULT.
What is the display history of DTC “B2098”?
“CRNT”>> GO TO 2.
“PAST” >> GO TO 5.
2.
CHECK IGNITION RELAY CONTROL CIRCUIT VOLTAGE 1
1. Turn ignition switch ON
2. Check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> GO TO 3.
3.
CHECK IGNITION RELAY CONTROL CIRCUIT VOLTAGE 2
1. Disconnect IPDM E/R connector.
2. Turn ignition switch ON
DTC
CONSULT display
description
DTC Detection Condition
Possible causes
B2098
IGN RELAY ON
CIRC
The ignition relay ON is detected for 1 second at ignition switch OFF
(CPU monitors the status at the contact and excitation coil circuits
of the ignition relay inside it)
Ignition relay malfunction
(+)
(–)
Voltage
(Approx.)
IPDM E/R
Connector
Terminal
E17
68
Ground
0 V
PCS
B2098 IGNITION RELAY ON STUCK
PCS-33
< DTC/CIRCUIT DIAGNOSIS >
[IPDM E/R]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
3. Check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
.
NO
>> Check the harness of the ignition relay control circuit for a short to power.
4.
CHECK IGNITION RELAY CONTROL CIRCUIT
1. Disconnect IPDM E/R connector.
2. Check continuity between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Perform the diagnosis procedure for DTC B26F2. Refer to
NO
>> Repair or replace harness.
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
.
>> INSPECTION END
(+)
(–)
Voltage
(Approx.)
IPDM E/R
Connector
Terminal
E17
68
Ground
0 V
IPDM E/R
Ground
Continuity
Connector
Terminal
E17
68
Not existed
PCS-34
< DTC/CIRCUIT DIAGNOSIS >
[IPDM E/R]
B2099 IGNITION RELAY OFF STUCK
B2099 IGNITION RELAY OFF STUCK
Description
INFOID:0000000012197170
• IPDM E/R operates the ignition relay when it receives an ignition switch ON signal from BCM via CAN com-
munication.
• Turn the ignition relay OFF by pressing the push-button ignition switch once when the vehicle speed is 4 km/
h (2.5 MPH) or less.
• Turn the ignition relay OFF with the following operation when the vehicle speed is more than 4 km/h (2.5
MPH) or when an abnormal condition occurs in CAN communication from the combination meter (Emer-
gency OFF)
- Press and hold the push-button ignition switch for 2 seconds or more.
- Press the push-button ignition switch 3 times within 1.5 seconds.
NOTE:
The ignition relay does not turn ON for 3 seconds after emergency OFF even if the push-button ignition switch
is pressed.
DTC Logic
INFOID:0000000012197171
DTC DETECTION LOGIC
NOTE:
When IPDM E/R power supply voltage is low (Approx. 7 - 8 V for about 1 second), the “DTC: B2099” may be detected.
1.
PERFORM DTC CONFIRMATION PROCEDURE
1. Turn ignition switch ON.
2. Check DTC in “Self Diagnostic Result” mode of “IPDM E/R” using CONSULT.
Is DTC detected?
YES
>> Refer to
.
NO
>> INSPECTION END.
Diagnosis Procedure
INFOID:0000000012197172
1.
CHECK FUSE
Check that all of the fuses installed on the downstream of the contact point side circuit of the ignition relay in
IPDM E/R are not blown.
Is the inspection result normal?
YES
>> GO TO 2.
NO
>> Replace the blown fuse after replacing the affected circuit if a fuse is blown.
2.
CHECK IGNITION RELAY CONTROL CIRCUIT VOLTAGE
1. Turn ignition switch ON
2. Check voltage between IPDM E/R harness connector and ground.
Is the inspection result normal?
YES
>> Replace IPDM E/R. Refer to
PCS-37, "Removal and Installation"
NO
>> GO TO 3.
DTC
CONSULT display
description
DTC Detection Condition
Possible causes
B2099
IGN RELAY OFF
CIRC
The ignition relay OFF is detected for 1 second at ignition switch ON
(CPU monitors the status at the contact and excitation coil circuits of
the ignition relay inside it)
Ignition relay malfunction
(+)
(–)
Voltage
(Approx)
IPDM E/R
Connector
Terminal
E17
68
Ground
0 V
PCS
B2099 IGNITION RELAY OFF STUCK
PCS-35
< DTC/CIRCUIT DIAGNOSIS >
[IPDM E/R]
C
D
E
F
G
H
I
J
K
L
B
A
O
P
N
3.
CHECK BATTERY VOLTAGE
Check battery voltage.
Which is the measurement result?
More than 12.4 V>>GO TO 4.
Less than 12.4 V>>Perform battery inspection. Refer to
PG-97, "How to Handle Battery"
.
4.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
.
>> INSPECTION END