Nissan Primera P12. Manual — part 690
SC-6
BATTERY
CHART II
●
Check battery type and determine the specified current using the following table.
Fig. 1 Discharging Current (Load Tester)
*.
SEL755W
Type
Current (A)
28B19R(L)
90
34B19R(L)
99
46B24R(L)
135
55B24R(L)
135
50D23R(L)
150
55D23R(L)
180
65D26R(L)
195
80D26R(L)
195
75D31R(L)
210
063 [YUASA type code]
210
95D31R(L)
240
115D31R(L)
240
025 [YUASA type code]
240
065 [YUASA type code]
255
027 [YUASA type code]
285
075 [YUASA type code]
300
110D26R(L)
300
95E41R(L)
300
067 [YUASA type code]
325
BATTERY
SC-7
C
D
E
F
G
H
I
J
L
M
A
B
SC
A: SLOW CHARGE
Fig. 2 Initial Charging Current Setting (Slow Charge)
●
Check battery type and determine the specified current using the table shown above.
●
After starting charging, adjustment of charging current is not necessary.
130E41R(L)
330
096 [YUASA type code]
375
096 [YUASA type code]
375
010S [YUASA type code]
360
Type
Current (A)
*1.
*2.
SEL756W
CON-
VERTED
SPECIFIC
GRAVITY
BATTERY TYPE
2
8
B
19
R
(L)
3
4
B
19
R
(L)
4
6
B
24
R
(L)
5
5
B
24
R
(L)
5
0
D
23
R
(L)
5
5
D
23
R
(L)
025
[Y
U
ASA
ty
p
e
code
]
027
[Y
U
ASA
ty
p
e
code
]
6
5
D
26
R
(L)
8
0
D
26
R
(L)
063
[Y
U
ASA
ty
p
e
code
]
067
[Y
U
ASA
ty
p
e
code
]
096
[Y
U
ASA
ty
pe
cod
e
]
7
5
D
31
R
(L)
9
5
D
31
R
(L)
1
1
5
D
31
R
(L)
1
1
0
D
26
R
(L)
9
5
E
41
R
(L)
065
[Y
U
ASA
ty
p
e
code
]
075
[Y
U
ASA
ty
p
e
code
]
09
6L
[Y
U
ASA
ty
pe
co
de]
01
0S
[Y
U
ASA
ty
pe
co
de]
13
0E41R
(L
)
Below
1.100
4.0 (A)
5.0 (A)
7.0 (A)
8.0 (A)
8.
5
(A)
9.
0
(A)
10.0 (A)
11.0 (A)
14
.0
(A)
SC-8
BATTERY
Fig. 3 Additional Charge (Slow Charge)
CAUTION:
●
Set charging current to value specified in Fig. 2. If charger is not capable of producing specified
current value, set its charging current as close to that value as possible.
●
Keep battery away from open flame while it is being charged.
●
When connecting charger, connect leads first, then turn on charger. Do not turn on charger first,
as this may cause a spark.
●
If battery temperature rises above 60
°
C (140
°
F), stop charging. Always charge battery when its
temperature is below 60
°
C (140
°
F).
B: STANDARD CHARGE
*.
SEL757W
*1.
*2.
SEL758W
BATTERY
SC-9
C
D
E
F
G
H
I
J
L
M
A
B
SC
Fig. 4 Initial Charging Current Setting (Standard Charge)
●
Check battery type and determine the specified current using the table shown above.
●
After starting charging, adjustment of charging current is not necessary.
Fig. 5 Additional Charge (Standard Charge)
CAUTION:
●
Do not use standard charge method on a battery whose specific gravity is less than 1.100.
●
Set charging current to value specified in Fig. 4. If charger is not capable of producing specified
current value, set its charging current as close to that value as possible.
●
Keep battery away from open flame while it is being charged.
●
When connecting charger, connect leads first, then turn on charger. Do not turn on charger first,
as this may cause a spark.
●
If battery temperature rises above 60
°
C (140
°
F), stop charging. Always charge battery when its
temperature is below 60
°
C (140
°
F).
CON-
VERTED
SPECIFIC
GRAVITY
BATTERY TYPE
28
B19R
(L
)
34
B19R
(L
)
46
B24R
(L
)
55
B24R
(L
)
50
D
23R
(L
)
55
D
23R
(L
)
02
5
[YUASA
type
cod
e
]
02
7
[YUASA
type
cod
e
]
65
D
26R
(L
)
80
D
26R
(L
)
06
3
[YUASA
type
cod
e
]
06
7
[YUASA
type
cod
e
]
09
6
[YUASA
type
cod
e
]
75
D
31R
(L
)
95
D
31R
(L
)
1
1
5
D
31R
(L
)
1
1
0
D
26R
(L
)
95
E41R
(L
)
06
5
[YUASA
type
cod
e
]
07
5
[YUASA
type
cod
e
]
0
96L
[Y
U
ASA
ty
p
e
code
]
010S
[Y
U
ASA
ty
p
e
c
ode]
130E4
1
R
(L
)
1.100 -
1.130
4.0 (A)
5.0 (A)
6.0 (A)
7.0 (A)
8.
0
(A)
9.0 (A)
10.0 (A)
13
.0
(A)
1.130 -
1.160
3.0 (A)
4.0 (A)
5.0 (A)
6.0 (A)
7.
0
(A)
8.0 (A)
9.0 (A)
11.
0
(A)
1.160 -
1.190
2.0 (A)
3.0 (A)
4.0 (A)
5.0 (A)
6.
0
(A)
7.0 (A)
8.0 (A)
9.
0
(A)
1.190 -
1.220
2.0 (A)
2.0 (A)
3.0 (A)
4.0 (A)
5.
0
(A)
5.0 (A)
6.0 (A)
7.
0
(A)
*.
SEL759W
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.