Nissan Juke (2016 year). Service Repair Manual — part 110
DLK-62
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
BACK DOOR OPENER SWITCH
3.
CHECK BACK DOOR OPENER SWITCH GROUND CIRCUIT
Check continuity between back door opener switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK BACK DOOR OPENER SWITCH
DLK-62, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door opener switch.
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000012196618
1.
CHECK BACK DOOR OPENER SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door opener switch connector.
3. Check continuity between back door opener switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door opener switch.
Back door opener switch
Ground
Continuity
Connector
Terminal
D107
2
Existed
Back door opener switch
Condition
Continuity
Terminal
1
2
Back door opener
switch
Pressed
Existed
Released
Not existed
Revision: November 2015
2016 JUKE
BACK DOOR REQUEST SWITCH
DLK-63
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BACK DOOR REQUEST SWITCH
Component Function Check
INFOID:0000000012196619
1.
CHECK FUNCTION
1. Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2. Select “REQ SW-BD/TR” in “DATA MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Back door request switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196620
1.
CHECK BACK DOOR REQUEST SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect back door opener switch connector.
3. Check voltage between back door opener switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK BACK DOOR REQUEST SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and back door opener switch harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
NO
>> Repair harness or connector.
3.
CHECK BACK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between back door opener switch harness connector and ground.
Monitor item
Condition
Status
REQ SW-BD/TR
Back door request switch
Pressed
On
Released
Off
(+)
(–)
Voltage
(Approx.)
Back door opener switch
Connector
Terminal
D107
3
Ground
12 V
BCM
Back door opener switch
Continuity
Connector
Terminal
Connector
Terminal
M68
51
D107
3
Existed
BCM
Ground
Continuity
Connector
Terminal
M68
51
Not existed
Back door opener switch
Ground
Continuity
Connector
Terminal
D107
4
Existed
Revision: November 2015
2016 JUKE
DLK-64
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
BACK DOOR REQUEST SWITCH
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK BACK DOOR REQUEST SWITCH
DLK-64, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace back door opener switch.
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000012196621
1.
CHECK BACK DOOR REQUEST SWITCH
1. Turn ignition switch OFF.
2. Disconnect back door opener switch connector.
3. Check continuity between back door opener switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace back door opener switch.
Back door opener switch
Condition
Continuity
Terminal
3
4
Back door request switch
Pressed
Existed
Released
Not existed
Revision: November 2015
2016 JUKE
BUZZER (COMBINATION METER)
DLK-65
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
BUZZER (COMBINATION METER)
Component Function Check
INFOID:0000000012196622
1.
CHECK FUNCTION
1. Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2. Select “INSIDE BUZZER” in “ACTIVE TEST” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
Yes
>> Buzzer (combination meter) is OK.
No
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196623
1.
CHECK METER BUZZER CIRCUIT
WCS-40, "Component Function Check"
.
Is the inspection result normal?
Yes
>> GO TO 2.
No
>> Repair or replace the malfunctioning parts.
2.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
.
>> INSPECTION END
Monitor item
Status
INSIDE BUZZER
Take Out
ON
Take away warning
Buzzer sounds
OFF
Buzzer does not sound
Key
ON
OFF position warning
Buzzer sounds
OFF
Buzzer does not sound
Revision: November 2015
2016 JUKE
DLK-66
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR KEY CYLINDER SWITCH
DOOR KEY CYLINDER SWITCH
Component Function Check
INFOID:0000000012196624
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “KEY CYL LK SW”, “KEY CYL UN-SW” in “DATA MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door key cylinder switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196625
1.
CHECK DOOR KEY CYLINDER SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front door lock assembly (driver side) connector.
3. Check voltage between front door lock assembly (driver side) harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR KEY CYLINDER SWITCH SIGNAL CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and front door lock assembly (driver side) harness
connector.
3. Check continuity between BCM harness connector and ground.
Monitor item
Condition
Status
KEY CYL LK-SW
Driver side door key cylinder
Lock
ON
Neutral / Unlock
OFF
KEY CYL UN-SW
Unlock
ON
Neutral / Lock
OFF
(+)
(–)
Voltage (V)
(Approx.)
Front door lock assembly (driver side)
Connector
Terminal
D38
5
Ground
8.0 - 8.5 V
6
Battery voltage
JPMIA0587GB
BCM
Front door lock assembly (driver side)
Continuity
Connector
Terminal
Connector
Terminal
M68
7
D38
5
Existed
8
6
Revision: November 2015
2016 JUKE
DOOR KEY CYLINDER SWITCH
DLK-67
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK DOOR KEY CYLINDER SWITCH GROUND CIRCUIT
Check continuity between front door lock assembly (driver side) harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR KEY CYLINDER SWITCH
DLK-67, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace front door lock assembly (driver side).
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
.
>> INSPECTION END
Component Inspection
INFOID:0000000012196626
1.
CHECK DOOR KEY CYLINDER SWITCH
1. Turn ignition switch OFF.
2. Disconnect front door lock assembly (driver side) terminal.
3. Check continuity between front door lock assembly (driver side) terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace front door lock assembly (driver side).
BCM
Ground
Continuity
Connector
Terminal
M68
7
Not existed
8
Front door lock assembly (driver side)
Ground
Continuity
Connector
Terminal
D38
4
Existed
Front door lock assembly (driver side)
Condition
Continuity
Terminal
5
4
Driver side door key cylinder
Unlock
Existed
Neutral / Lock
Not existed
6
Lock
Existed
Neutral / Unlock
Not existed
Revision: November 2015
2016 JUKE
DLK-68
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK ACTUATOR
DOOR LOCK ACTUATOR
DRIVER SIDE
DRIVER SIDE : Component Function Check
INFOID:0000000012196627
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR LOCK” in “ACTIVE TEST” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-68, "DRIVER SIDE : Diagnosis Procedure"
DRIVER SIDE : Diagnosis Procedure
INFOID:0000000012196628
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front door lock assembly (driver side) connector.
3. Check voltage between front door lock assembly (driver side) harness connector and ground.
Is the inspection result normal?
YES
>> Replace front door lock assembly (driver side).
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Disconnect BCM connector and all door lock assembly connector.
2. Check continuity between BCM harness connector and front door lock assembly (driver side) harness
connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
(+)
(–)
Condition
Voltage
(Approx.)
Front door lock assembly
(driver side)
Connector
Terminal
D38
2
Ground
Door lock and unlock switch
Unlock
12 V
1
Lock
BCM
Front door lock assembly (driver side)
Continuity
Connector
Terminal
Connector
Terminal
M69
65
D38
1
Existed
66
2
BCM
Ground
Continuity
Connector
Terminal
M69
65
Not existed
66
Revision: November 2015
2016 JUKE
DOOR LOCK ACTUATOR
DLK-69
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
3.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
PASSENGER SIDE
PASSENGER SIDE : Component Function Check
INFOID:0000000012196629
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR LOCK” in “ACTIVE TEST” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-68, "DRIVER SIDE : Diagnosis Procedure"
PASSENGER SIDE : Diagnosis Procedure
INFOID:0000000012196630
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect front door lock assembly (passenger side) connector.
3. Check voltage between front door lock assembly (passenger side) harness connector and ground.
Is the inspection result normal?
YES
>> Replace front door lock assembly (passenger side).
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Disconnect BCM connector and all door lock assembly connector.
2. Check continuity between BCM harness connector and front door lock assembly (passenger side) har-
ness connector.
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M69
66
Ground
Door lock and unlock switch
Unlock
12 V
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
(+)
(–)
Condition
Voltage
(Approx.)
Front door lock assembly
(passenger side)
Connector
Terminal
D17
6
Ground
Door lock and unlock switch
Unlock
12 V
5
Lock
Revision: November 2015
2016 JUKE
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.