Nissan Juke (2016 year). Service Repair Manual — part 111
DLK-70
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK ACTUATOR
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
REAR LH
REAR LH : Component Function Check
INFOID:0000000012196631
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR LOCK” in “ACTIVE TEST” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-68, "DRIVER SIDE : Diagnosis Procedure"
REAR LH : Diagnosis Procedure
INFOID:0000000012196632
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect rear door lock assembly LH connector.
3. Check voltage between rear door lock assembly LH harness connector and ground.
BCM
Front door lock assembly (passenger side)
Continuity
Connector
Terminal
Connector
Terminal
M69
59
D17
6
Existed
65
5
BCM
Ground
Continuity
Connector
Terminal
M69
59
Not existed
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
M69
59
Ground
Door lock and unlock switch
Unlock
12 V
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
Revision: November 2015
2016 JUKE
DOOR LOCK ACTUATOR
DLK-71
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
Is the inspection result normal?
YES
>> Replace rear door lock assembly LH.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Disconnect BCM connector and all door lock assembly connector.
2. Check continuity between BCM harness connector and rear door lock assembly LH harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
REAR RH
REAR RH : Component Function Check
INFOID:0000000012196633
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR LOCK” in “ACTIVE TEST” mode.
3. Check that the function operates normally according to the following conditions.
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock assembly LH
Connector
Terminal
D65
2
Ground
Door lock and unlock switch
Unlock
12 V
1
Lock
BCM
Rear door lock assembly LH
Continuity
Connector
Terminal
Connector
Terminal
B10
55
D65
2
Existed
M69
65
1
BCM
Ground
Continuity
Connector
Terminal
B10
55
Not existed
M69
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
B10
55
Ground
Door lock and unlock switch
Unlock
12 V
M69
65
Lock
Monitor item
Status
DOOR LOCK
ALL LOCK
Door lock actuators
LOCK
ALL UNLK
UNLOCK
Revision: November 2015
2016 JUKE
DLK-72
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK ACTUATOR
Is the inspection result normal?
YES
>> Door lock actuator is OK.
NO
>> Refer to
DLK-68, "DRIVER SIDE : Diagnosis Procedure"
REAR RH : Diagnosis Procedure
INFOID:0000000012196634
1.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect rear door lock assembly RH connector.
3. Check voltage between rear door lock assembly RH harness connector and ground.
Is the inspection result normal?
YES
>> Replace rear door lock assembly RH.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
1. Disconnect BCM connector and all door lock assembly connector.
2. Check continuity between BCM harness connector and rear door lock assembly RH harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> Repair or replace harness.
3.
CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM harness connector and ground.
Is the inspection result normal?
YES
>> Check for internal short of each door lock actuator.
NO
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
(+)
(–)
Condition
Voltage
(Approx.)
Rear door lock assembly RH
Connector
Terminal
D45
6
Ground
Door lock and unlock switch
Unlock
12 V
5
Lock
BCM
Rear door lock assembly RH
Continuity
Connector
Terminal
Connector
Terminal
B10
55
D45
6
Existed
M69
65
5
BCM
Ground
Continuity
Connector
Terminal
B10
55
Not existed
M69
65
(+)
(–)
Condition
Voltage
(Approx.)
BCM
Connector
Terminal
B10
55
Ground
Door lock and unlock switch
Unlock
12 V
M69
65
Lock
Revision: November 2015
2016 JUKE
DOOR LOCK AND UNLOCK SWITCH
DLK-73
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR LOCK AND UNLOCK SWITCH
Component Function Check
INFOID:0000000012196635
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “CDL LOCK SW”, “CDL UNLOCK SW” in “DATA MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door lock and unlock switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196636
1.
CHECK DOOR LOCK AND UNLOCK SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect power window main switch connector.
3. Check signal between power window main switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR LOCK AND UNLOCK SWITCH CIRCUIT
1. Disconnect BCM connector and power window main switch connector.
2. Check continuity between BCM harness connector and power window main switch harness connector.
3. Check continuity between BCM harness connector and ground.
Monitor item
Condition
Status
CDL LOCK SW
Door lock and unlock switch
Lock
ON
Unlock
OFF
CDL UNLOCK SW
Lock
OFF
Unlock
ON
(+)
(–)
Signal
(Reference value)
Power window main switch
Connector
Terminal
D35
3
Ground
1.0 - 1.5 V
15
JPMIA0012GB
BCM
Power window main switch
Continuity
Connector
Terminal
Connector
Terminal
M68
12
D35
3
Existed
13
15
Revision: November 2015
2016 JUKE
DLK-74
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR LOCK AND UNLOCK SWITCH
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
NO
>> Repair or replace harness.
3.
CHECK DOOR LOCK AND UNLOCK SWITCH GROUND
Check continuity between power window main switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR LOCK AND UNLOCK SWITCH
DLK-74, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace power window main switch. Refer to
PWC-54, "Removal and Installation"
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000012196637
1.
CHECK DOOR LOCK AND UNLOCK SWITCH
1. Turn ignition switch OFF.
2. Disconnect power window main switch connector.
3. Check continuity between power window main switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace power window main switch.
BCM
Ground
Continuity
Connector
Terminal
M68
12
Not existed
13
Power window main switch
Ground
Continuity
Connector
Terminal
D35
1
Existed
Power window main switch
Condition
Continuity
Terminal
3
1
Door lock and unlock
switch
LOCK
Existed
UNLOCK
Not existed
15
LOCK
Not existed
UNLOCK
Existed
Revision: November 2015
2016 JUKE
DOOR REQUEST SWITCH
DLK-75
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR REQUEST SWITCH
Component Function Check
INFOID:0000000012196638
1.
CHECK FUNCTION
1. Select “INTELLIGENT KEY” of “BCM” using CONSULT.
2. Select “REQ SW-DR”, “REQ SW-AS” in “DATA MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Front door request switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196639
1.
CHECK DOOR REQUEST SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect malfunctioning front door request switch connector.
3. Check voltage between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 3.
NO
>> GO TO 2.
2.
CHECK DOOR REQUEST SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between malfunctioning front door request switch harness connector and BCM harness
connector.
3. Check continuity between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> Replace BCM. Refer to
BCS-94, "Removal and Installation"
NO
>> Repair or replace harness.
Monitor item
Condition
Status
REQ SW -DR
Driver side door request switch
Pressed
ON
Released
OFF
REQ SW -AS
Passenger side door request switch
Pressed
ON
Released
OFF
(+)
(–)
Voltage
(Approx.)
Front door request switch
Connector
Terminal
Driver side
D34
2
Ground
12 V
Passenger side
D15
1
Front door request switch
BCM
Continuity
Connector
Terminal
Connector
Terminal
Driver side
D34
2
M70
75
Existed
Passenger side
D15
1
100
Front door request switch
Ground
Continuity
Connector
Terminal
Driver side
D34
2
Not existed
Passenger side
D15
1
Revision: November 2015
2016 JUKE
DLK-76
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
DOOR REQUEST SWITCH
3.
CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between malfunctioning front door request switch harness connector and ground.
Is the inspection result normal?
YES
>> GO TO 4.
NO
>> Repair or replace harness.
4.
CHECK DOOR REQUEST SWITCH
DLK-76, "Component Inspection"
Is the inspection result normal?
YES
>> GO TO 5.
NO
>> Replace malfunctioning front door request switch.
5.
CHECK INTERMITTENT INCIDENT
GI-45, "Intermittent Incident"
>> INSPECTION END
Component Inspection
INFOID:0000000012196640
1.
CHECK DOOR REQUEST SWITCH
1. Turn ignition switch OFF.
2. Disconnect malfunctioning front door request switch connector.
3. Check continuity between malfunctioning front door request switch terminals.
Is the inspection result normal?
YES
>> INSPECTION END
NO
>> Replace malfunctioning front door request switch.
Front door request switch
Ground
Continuity
Connector
Terminal
Driver side
D34
1
Existed
Passenger side
D15
2
Front door request switch
Condition
Continuity
Terminal
1
2
Door request switch
Pressed
Existed
Released
Not existed
Revision: November 2015
2016 JUKE
DOOR SWITCH
DLK-77
< DTC/CIRCUIT DIAGNOSIS >
[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
M
A
B
DLK
N
O
P
DOOR SWITCH
Component Function Check
INFOID:0000000012196641
1.
CHECK FUNCTION
1. Select “DOOR LOCK” of “BCM” using CONSULT.
2. Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL”, “DOOR SW-RR”, “DOOR SW-BK” in “DATA
MONITOR” mode.
3. Check that the function operates normally according to the following conditions.
Is the inspection result normal?
YES
>> Door switch is OK.
NO
>> Refer to
.
Diagnosis Procedure
INFOID:0000000012196642
1.
CHECK DOOR SWITCH INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect malfunctioning door switch connector.
3. Check signal between malfunctioning door switch harness connector and ground using oscilloscope.
Is the inspection result normal?
YES-1 >> Back door: GO TO 3.
YES-2 >> Other door: GO TO 4.
NO
>> GO TO 2.
2.
CHECK DOOR SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between door switch harness connector and BCM harness connector.
Monitor item
Condition
Status
DOOR SW-DR
Driver side door
Open
On
Closed
Off
DOOR SW-AS
Passenger side door
Open
On
Closed
Off
DOOR SW-RL
Rear door LH
Open
On
Closed
Off
DOOR SW-RR
Rear door RH
Open
On
Closed
Off
DOOR SW-BK
Back door
Open
On
Closed
Off
(+)
(–)
Signal
(Reference value)
Door switch
Connector
Terminal
Driver side
B48
2
Ground
7.0 - 8.0 V
Passenger side
B49
Rear LH
B71
Rear RH
B53
Back door
D106
3
PKIB4960J
Revision: November 2015
2016 JUKE