Nissan Murano Z51 (2008 year). Manual — part 387
VTL-12
< PRECAUTION >
[WITHOUT 7 INCH DISPLAY]
PRECAUTIONS
• Perform leakage test and check that there is no leakage from connections after connecting the line.
Disconnect the line and replace the O-ring when the refrigerant leakage point is found. Then tighten
the connections of seal seat to the specified torque.
Service Equipment
INFOID:0000000003072881
RECOVERY/RECYCLING EQUIPMENT
Be certain to follow the manufacturer instructions for machine operation and machine maintenance. Never
introduce any refrigerant other than that specified into the machine.
ELECTRICAL LEAK DETECTOR
Be certain to follow the manufacturer instructions for tester operation and tester maintenance.
VACUUM PUMP
The lubricant contained inside the vacuum pump is not compatible
with the specified lubricant for HFC-134a (R-134a) A/C systems.
The vent side of the vacuum pump is exposed to atmospheric pres-
sure. So the vacuum pump lubricant may migrate out of the pump
into the service hose. This is possible when the pump is switched
OFF after evacuation (vacuuming) and the hose is connected to it.
To prevent this migration, use a manual valve placed near the hose-
to-pump connection, as per the following procedure.
• Vacuum pumps usually have a manual isolator valve as part of the
pump. Close this valve to isolate the service hose from the pump.
• Use a hose equipped with a manual shut-off valve near the pump
end for pumps without an isolator. Close the valve to isolate the
hose from the pump.
• Disconnect the hose from the pump if the hose has an automatic
shut-off valve. As long as the hose is connected, the valve is open
and lubricating oil may migrate.
Some one-way valves open when vacuum is applied and close
under the no vacuum condition. Such valves may restrict the ability
of the pump to create a deep vacuum and are not recommended.
MANIFOLD GAUGE SET
RHA861F
RHA270DA
Revision: 2008 October
2009 Murano
PRECAUTIONS
VTL-13
< PRECAUTION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
Be certain that the gauge face indicates HFC-134a or R-134a. Be
sure the gauge set has 1/2
″
-16 ACME threaded connections for ser-
vice hoses. Confirm the set has been used only with refrigerant
HFC-134a (R-134a) and specified lubricants.
SERVICE HOSES
Be certain that the service hoses display the markings described
(colored hose with a black stripe). All hoses must equip positive
shut-off devices (either manual or automatic) near the end of the
hoses opposite to the manifold gauge.
SERVICE COUPLERS
Never attempt to connect HFC-134a (R-134a) service couplers to a
CFC-12 (R-12) A/C system. The HFC-134a (R-134a) couplers do
not properly connect to the CFC-12 (R-12) system. However, if an
improper connection is attempted, discharging and contamination
may occur.
REFRIGERANT WEIGHT SCALE
Verify that no refrigerant other than HFC-134a (R-134a) and speci-
fied lubricants have been used with the scale. The hose fitting must
be 1/2
″
-16 ACME if the scale controls refrigerant flow electronically.
CHARGING CYLINDER
Use of a charging cylinder is not recommended. Refrigerant may be vented into the air from the top valve of
the cylinder when filling the cylinder with refrigerant. Also, the accuracy of the cylinder is generally less than
that of an electronic scale or of quality recycle/recharge equipment.
SHA533D
RHA272D
Shut-off valve rotation
A/C service valve
Clockwise
Open
Counterclockwise
Close
RHA273D
RHA274D
Revision: 2008 October
2009 Murano
VTL-14
< PRECAUTION >
[WITHOUT 7 INCH DISPLAY]
COMPRESSOR
COMPRESSOR
General Precautions
INFOID:0000000003072882
CAUTION:
• Plug all openings to prevent moisture and foreign material from entering.
• Store it in the same way as it is when mounted on the car when the compressor is removed.
• Follow “Maintenance of Lubricant Quantity in Compressor” exactly when replacing or repairing
compressor. Refer to
HA-25, "Maintenance of Lubricant Quantity"
• Keep friction surfaces between clutch and pulley clean. Wipe it off by using a waste moistened with
thinner if the surface is contaminated with lubricant.
• Turn the compressor shaft by hand more than five turns in both directions after compressor service
operation. This equally distributes lubricant inside the compressor. Let the engine idle and operate
the compressor for one hour after the compressor is installed.
• Apply voltage to the new compressor and check for normal operation after replacing the compressor
magnet clutch.
Revision: 2008 October
2009 Murano
FLUORESCENT LEAK DETECTOR
VTL-15
< PRECAUTION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
FLUORESCENT LEAK DETECTOR
General Precautions
INFOID:0000000003072883
CAUTION:
• The A/C system contains a fluorescent leak detection dye used for locating refrigerant leakages. An
ultraviolet (UV) lamp is required to illuminate the dye when inspecting for leakages.
• Always wear fluorescence enhancing UV safety goggles to protect eyes and enhance the visibility of
the fluorescent dye.
• The fluorescent dye leak detector is not a replacement for an electrical leak detector (SST: J-41995).
The fluorescent dye leak detector should be used in conjunction with an electrical leak detector
(SST: J-41995) to pin-point refrigerant leakages.
• Read and follow all manufacturer operating instructions and precautions prior to performing work
for safety and customer satisfaction.
• A compressor shaft seal should not necessarily be repaired because of dye seepage. The compres-
sor shaft seal should only be repaired after confirming the leakage with an electrical leak detector
(SST: J-41995).
• Always remove any remaining dye from the leakage area after repairs are completed to avoid a mis-
diagnosis during future service.
• Never allow dye to come into contact with painted body panels or interior components. Immediately
clean with the approved dye cleaner if dye is spilled. Fluorescent dye left on a surface for an
extended period of time cannot be removed.
• Never spray fluorescent dye cleaning agent on hot surfaces (engine exhaust manifold, etc.).
• Never use more than one refrigerant dye bottle [1/4 ounce (7.4 cc)] per A/C system.
• Leak detection dyes for HFC-134a (R-134a) and CFC-12 (R-12) A/C systems are different. Never use
HFC-134a (R-134a) leak detection dye in CFC-12 (R-12) A/C system or CFC-12 (R-12) leak detection
dye in HFC-134a (R-134a) A/C system, otherwise A/C system damage may result.
• The fluorescent properties of the dye remains for three or more years unless a compressor malfunc-
tion occurs.
IDENTIFICATION
NOTE:
Vehicles with factory installed fluorescent dye have a green label.
Vehicles without factory installed fluorescent dye have a blue label.
IDENTIFICATION LABEL FOR VEHICLE
Vehicles with factory installed fluorescent dye have an identification label on the front side of hood.
Revision: 2008 October
2009 Murano
VTL-16
< PREPARATION >
[WITHOUT 7 INCH DISPLAY]
PREPARATION
PREPARATION
PREPARATION
Special Service Tool
INFOID:0000000003072884
The actual shapes of Kent-Moore tools may differ from those of special service tools illustrated here.
HFC-134a (R-134a) Service Tool and Equipment
• Never mix HFC-134a (R-134a) refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/
or its lubricant.
• Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
• Refrigerant container fittings, service hose fittings and service equipment fittings (equipment that handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
• Never use adapters that convert one size fitting to another. Refrigerant/lubricant contamination occurs and
compressor malfunction may result.
Tool number
(Kent-Moore No.)
Tool name
Description
(ACR2005-NI)
ACR5 A/C Service Center
Function: Refrigerant recovery, recycling
and recharging
(J-41995)
Electrical leak detector
Power supply:
DC 12 V (Battery terminal)
(J-43926)
Refrigerant dye leak detection
kit
Kit includes:
(J-42220)
UV lamp and UV safety goggles
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
(J-43872)
Refrigerant dye cleaner
Power supply:
DC 12 V (Battery terminal)
WJIA0293E
AHA281A
ZHA200H
Revision: 2008 October
2009 Murano
PREPARATION
VTL-17
< PREPARATION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
(J-42220)
UV lamp and UV safety goggles
Power supply:
DC 12 V (Battery terminal)
For checking refrigerant leakage when flu-
orescent dye is equipped in A/C system
Includes:
UV lamp and UV safety goggles
(J-41447)
HFC-134a (R-134a) fluorescent
leak detection dye
(Box of 24, 1/4 ounce bottles)
Application:
For HFC-134a (R-134a) PAG oil
Container:
1/4 ounce (7.4 cc) bottle
(Includes self-adhesive dye identification
labels for affixing to vehicle after charging
system with dye.)
(J-41459)
HFC-134a (R-134a) dye injector
Use with J-41447, 1/4 ounce
bottle
For injecting 1/4 ounce of fluorescent leak
detection dye into A/C system
(J-43872)
Refrigerant dye cleaner
For cleaning dye spills
(J-39183)
Manifold gauge set (with hoses
and couplers)
Identification:
• The gauge face indicates HFC-134a (R-
134a).
Fitting size: Thread size
• 1/2
″
-16 ACME
Service hoses
• High-pressure side hose
(J-39501-72)
• Low-pressure side hose
(J-39502-72)
• Utility hose
(J-39476-72)
Hose color:
• Low-pressure side hose: Blue with black
stripe
• High-pressure side hose: Red with black
stripe
• Utility hose: Yellow with black stripe or
green with black stripe
Hose fitting to gauge:
• 1/2
″
-16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
SHA438F
SHA439F
SHA440F
SHA441F
RJIA0196E
S-NT201
Revision: 2008 October
2009 Murano
VTL-18
< PREPARATION >
[WITHOUT 7 INCH DISPLAY]
PREPARATION
Commercial Service Tool
INFOID:0000000003072885
Service couplers
• High-pressure side coupler
(J-39500-20)
• Low-pressure side coupler
(J-39500-24)
Hose fitting to service hose:
M14 x 1.5 fitting is optional or permanently
attached.
(J-39650)
Refrigerant weight scale
For measuring of refrigerant
Fitting size: Thread size
1/2
″
-16 ACME
(J-39649)
Vacuum pump
(Including the isolator valve)
Capacity:
• Air displacement: 4 CFM
• Micron rating: 20 microns
• Oil capacity: 482 g (17 oz.)
Fitting size: Thread size
• 1/2
″
-16 ACME
Tool number
(Kent-Moore No.)
Tool name
Description
S-NT202
S-NT200
S-NT203
Tool name
Description
Refrigerant identifier equipment
Checking for refrigerant purity and
system contamination
Power tools
For loosening bolts and nuts
Remover tools
Remove clips, pawls, metal clips
RJIA0197E
PBIC0190E
PIIB7923J
Revision: 2008 October
2009 Murano
PREPARATION
VTL-19
< PREPARATION >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
Sealant or/and Lubricant
INFOID:0000000003072886
HFC-134a (R-134a) Service Tool and Equipment
• Never mix HFC-134a (R-134a) refrigerant and/or its specified lubricant with CFC-12 (R-12) refrigerant and/
or its lubricant.
• Separate and non-interchangeable service equipment must be used for handling each type of refrigerant/
lubricant.
• Refrigerant container fittings, service hose fittings and service equipment fittings (equipment that handles
refrigerant and/or lubricant) are different between CFC-12 (R-12) and HFC-134a (R-134a). This is to avoid
mixed use of the refrigerants/lubricant.
• Never use adapters that convert one size fitting to another. Refrigerant/lubricant contamination occurs and
compressor malfunction may result.
Tool name
Description
HFC-134a (R-134a) refrigerant
Container color: Light blue
Container marking: HFC-134a (R-
134a)
Fitting size: Thread size
• Large container 1/2
″
-16 ACME
NISSAN A/C System Oil Type S
(DH-PS)
Type: Polyalkylene glycol oil (PAG),
type S (DH-PS)
Application:
HFC-134a (R-134a) swash plate com-
pressors (NISSAN only)
Capacity: 40 m
(1.4 US fl oz., 1.4
Imp fl oz.)
S-NT196
S-NT197
Revision: 2008 October
2009 Murano
VTL-20
< ON-VEHICLE MAINTENANCE >
[WITHOUT 7 INCH DISPLAY]
IN-CABIN MICROFILTER
ON-VEHICLE MAINTENANCE
IN-CABIN MICROFILTER
Exploded View
INFOID:0000000004676921
Removal and Installation
INFOID:0000000003072888
REMOVAL
1.
Remove the filter cover (1), and then remove the in-cabin micro-
filter (2).
INSTALLATION
Install in the reverse order of removal.
CAUTION:
• If the filter is deformed/damaged when removing, replace it with a new one. Deformed/damaged fil-
termay deteriorate the dust collecting performance.
• When installing, handle the filter with extreme care to avoid deforming/damaging.
Replacement
INFOID:0000000003072889
Replace in-cabin microfilter.
Refer to [
MA-8, "FOR NORTH AMERICA : Schedule 1"
MA-10, "FOR NORTH AMERICA : Schedule 2"
(FOR NORTH AMERICA)] or
MA-11, "FOR MEXICO : Periodic Maintenance"
(FOR MEXICO).
Affix a caution label inside the glove box when replacing filter.
1.
Heater & cooling unit assembly
2.
In-cabin microfilter
3.
Filter cover
JPIIA0895ZZ
JPIIA0552ZZ
Revision: 2008 October
2009 Murano
A/C CONTROL
VTL-21
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
ON-VEHICLE REPAIR
A/C CONTROL
Exploded View
INFOID:0000000003208740
DISASSEMBLY
Removal and Installation
INFOID:0000000003208741
REMOVAL
1.
Remove the instrument stay cover LH. Refer to
.
2.
Remove the instrument stay cover RH. Refer to
3.
Remove the mounting screws (A), and then remove the cluster
lid D (1).
4.
Remove the mounting screws (A), and then remove the A/C
control (1).
INSTALLATION
1.
Cluster lid D
2.
A/C control
JPIIA0600ZZ
JPIIA0601ZZ
JPIIA0602ZZ
Revision: 2008 October
2009 Murano
VTL-22
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
A/C CONTROL
Install in the reverse order of removal.
Revision: 2008 October
2009 Murano
A/C DISPLAY
VTL-23
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
A/C DISPLAY
Exploded View
INFOID:0000000003457773
DISASSEMBLY
Removal and Installation
INFOID:0000000003457774
REMOVAL
1.
Remove the central ventilator assembly. Refer to
.
2.
Remove the mounting screws (A), and then remove the mount-
ing bracket (1).
3.
Remove the mounting screws (A), and then remove the A/C dis-
play (1).
INSTALLATION
Install in the reverse order of removal.
1.
Bracket
2.
A/C display
3.
CRT filter
4.
AV display
JPIIA0603ZZ
JPIIA0604ZZ
JPIIA0605ZZ
Revision: 2008 October
2009 Murano
VTL-24
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
A/C AUTO AMP.
A/C AUTO AMP.
Exploded View
INFOID:0000000003072892
DISASSEMBLY
Removal and Installation
INFOID:0000000003072893
REMOVAL
1.
Remove the AV control unit. Refer to
2.
Remove the mounting screws (A), and then remove the A/C
auto amp. (1).
INSTALLATION
Install in the reverse order of removal.
JPIIA0553ZZ
1.
AV control unit
2.
Bracket (LH)
3.
A/C auto amp.
4.
Bracket (RH)
JPIIA0554ZZ
Revision: 2008 October
2009 Murano
AMBIENT SENSOR
VTL-25
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
AMBIENT SENSOR
Exploded View
INFOID:0000000003072894
Removal and Installation
INFOID:0000000003072895
REMOVAL
1.
Disconnect the ambient sensor connector (A), and then remove
the ambient sensor (1).
INSTALLATION
Install in the reverse order of removal.
1.
Ambient sensor
JPIIA1300ZZ
JPIIA0556ZZ
Revision: 2008 October
2009 Murano
VTL-26
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
IN-VEHICLE SENSOR
IN-VEHICLE SENSOR
Exploded View
INFOID:0000000003072896
Removal and Installation
INFOID:0000000003072897
REMOVAL
1.
Remove the instrument lower panel LH. Refer to
.
2.
Remove the mounting screw (A), and then remove the in-vehicle
sensor (1).
INSTALLATION
Install in the reverse order of removal.
1.
In-vehicle sensor
2.
Instrument lower panel LH
JPIIA0557ZZ
JPIIA0558ZZ
Revision: 2008 October
2009 Murano
SUNLOAD SENSOR
VTL-27
< ON-VEHICLE REPAIR >
[WITHOUT 7 INCH DISPLAY]
C
D
E
F
G
H
J
K
L
M
A
B
VTL
N
O
P
SUNLOAD SENSOR
Exploded View
INFOID:0000000003072898
Removal and Installation
INFOID:0000000003072899
REMOVAL
1.
Disconnect the sunload sensor connector, and then remove the
sunload sensor (1).
INSTALLATION
Install in the reverse order of removal.
1.
Sunload sensor
JPIIA0559ZZ
JPIIA0560ZZ
Revision: 2008 October
2009 Murano
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.