Toyota Tundra (2015 year). Manual — part 362
OK
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
8 (SR) - Body ground
20°C (68°F)
11 to 15 Ω
Text in Illustration
*a
Component without harness connected
(Transmission Wire)
NG
GO TO STEP 3
2.
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
(a) Disconnect the D74 ECM connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
D74-4 (SR) - Body ground
20°C (68°F)
11 to 15 Ω
Text in Illustration
*a
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
REPLACE ECM
3.
INSPECT SHIFT SOLENOID VALVE SR
A760E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMIS...
(a) Remove shift solenoid valve SR.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
TESTER CONNECTION
CONDITION SPECIFIED CONDITION
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body
20°C (68°F)
11 to 15 Ω
(c) Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an
operating noise.
OK:
MEASUREMENT CONDITION
SPECIFIED CONDITION
Battery positive (+) → Shift solenoid valve SR connector
Battery negative (-) → Shift solenoid valve SR body
Valve moves and makes an operating noise
Text in Illustration
*a
Component without harness connected
(Shift Solenoid Valve SR)
NG
REPLACE SHIFT SOLENOID VALVE SR
OK
REPAIR OR REPLACE TRANSMISSION WIRE
A760E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMIS...
Last Modified: 9-16-2014
6.6 C
Doc ID: RM000000W8A0M4X
Model Year: 2015
Model: Tundra
Prod Date Range: [08/2014 - ]
Title: A760E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMISSION SYSTEM: P2716; Pressure Control
Solenoid "D" Electrical (Shift Solenoid Valve SLT); 2015 MY Tundra [08/2014 - ]
DTC
P2716
Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
DESCRIPTION
Refer to DTC P0894
.
DTC
CODE
DTC DETECTION CONDITION
TROUBLE AREA
P2716
Open or short is detected in the shift solenoid valve SLT circuit
for 1 second or more while driving (1-trip detection logic).
Open or short in shift
solenoid valve SLT circuit
Shift solenoid valve SLT
ECM
MONITOR DESCRIPTION
When an open or short in the shift solenoid valve SLT circuit is detected, the ECM interprets this as a fault. The
ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Duration
1 second
MIL operation
Immediately
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not present
None
Solenoid current cut status
Not cut
Battery voltage
11 V or more
Ignition switch
ON
Starter
OFF
TYPICAL MALFUNCTION THRESHOLDS
Solenoid voltage monitor signal from solenoid driver MIC
No signal
A760E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMIS...
COMPONENT OPERATING RANGE
Output signal duty
Less than 100%
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
Perform the universal trip to clear permanent DTCs
.
PROCEDURE
1.
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLT)
(a) Disconnect the D83 transmission wire connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
A760E AUTOMATIC TRANSMISSION: AUTOMATIC TRANSMIS...