Toyota Tundra (2015 year). Manual — part 2098
(a) for LH:
(1) Disconnect the A12 light connector.
(2) Disconnect the J29 relay connector.
(3) Measure the resistance according to the value(s) in the table below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
A12-3 (B) - J29-10 (TRNL)
Always
Below 1 Ω
A12-2 (E) - Body ground
A12-3 (B) - Body ground
Always
10 kΩ or higher
LIGHTING: LIGHTING SYSTEM: Turn Signal Light Circuit; 2015 M...
(b) for RH:
(1) Disconnect the A13 light connector.
(2) Disconnect the J29 relay connector.
(3) Measure the resistance according to the value(s) in the table below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
A13-3 (B) - J29-17 (TRNR)
Always
Below 1 Ω
A13-2 (E) - Body ground
A13-3 (B) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN
IN PROBLEM SYMPTOMS TABLE
5.
CHECK HARNESS AND CONNECTOR (REAR COMBINATION LIGHT - TURN SIGNAL
FLASHER AND BODY GROUND)
(a) for LH:
(1) Disconnect the R13 light connector.
(2) Disconnect the J29 relay connector.
(3) Measure the resistance according to the value(s) in the table below.
LIGHTING: LIGHTING SYSTEM: Turn Signal Light Circuit; 2015 M...
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
R13-1 (TRN) - J29-2 (LL)
Always
Below 1 Ω
R13-2 (E) - Body ground
R13-1 (TRN) - Body ground
Always
10 kΩ or higher
(b) for RH:
(1) Disconnect the R14 light connector.
(2) Disconnect the J29 relay connector.
(3) Measure the resistance according to the value(s) in the table below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
R14-1 (TRN) - J29-8 (LR)
Always
Below 1 Ω
R14-2 (GND) - Body ground
R14-1 (TRN) - Body ground
Always
10 kΩ or higher
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN
IN PROBLEM SYMPTOMS TABLE
6.
CHECK HARNESS AND CONNECTOR (OUTER REAR VIEW MIRROR - TURN SIGNAL
FLASHER AND BODY GROUND)
LIGHTING: LIGHTING SYSTEM: Turn Signal Light Circuit; 2015 M...
(a) for LH:
(1) Disconnect the N5 light connector.
(2) Disconnect the J29 relay connector.
(3) Measure the resistance according to the value(s) in the table below.
Standard resistance:
TESTER CONNECTION
CONDITION
SPECIFIED CONDITION
N5-4 (TRNL) - J29-2 (LL)
Always
Below 1 Ω
N5-3 (GND) - Body ground
N5-4 (TRNL) - Body ground
Always
10 kΩ or higher
LIGHTING: LIGHTING SYSTEM: Turn Signal Light Circuit; 2015 M...