Ford Ranger EV (2001 year). Manual — part 176
414-03B-100
414-03B-100
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
2. Remove the traction battery cover.
1 Remove the 22 bolts.
2 Remove the cover.
3.
WARNING: The nominal voltage of
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.
4.
CAUTION: Disconnect only one HVJ
at a time.
Disconnect the HVJs from the contactor box.
•
Open the cap.
•
Remove the bolt.
5. Wrap the HVJ ends with orange electrical tape.
414-03B-101
414-03B-101
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
6. Remove the two-pin high-voltage connector
nuts.
7. Disconnect the high-voltage interlock electrical
connector.
8. Disconnect the low-voltage electrical connector.
9. Unclip the thermistors from the high-voltage
harness and cut the zip tie.
414-03B-102
414-03B-102
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
10. Open the clips that secure the contactor box
harness to the high-voltage harness.
11. Cut the two zip ties securing the contactor box
harness.
12. Disconnect the contactor box harness.
13. NOTE: The contactor box is held in place with
strips of Velcro
TM
.
Remove the contactor box.
414-03B-103
414-03B-103
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
Installation
1. To install, reverse the removal procedure.
•
Fill the high-voltage jumper connectors with
Nyogel after final tightening of the
nuts/bolts.
•
Apply Locktite 242 to the 22 traction
battery cover bolts.
Contactor Box Fuses
Removal
Нет комментариевНе стесняйтесь поделиться с нами вашим ценным мнением.