Ford Ranger EV (2001 year). Manual — part 183
414-03B-128
414-03B-128
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
6. Remove the low-voltage harness push pin.
7. Remove the battery hold down bracket.
1 Remove bolts.
2 Remove the bracket.
8. Remove the battery hold down bracket.
1 Remove the bolts.
2 Remove the bracket.
9. Disconnect the blower thermistor electrical
connector.
414-03B-129
414-03B-129
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
10. NOTE: Two of the bolts secure hold down
brackets to the cover.
Remove the blower cover.
1 Remove the bolts.
2 Remove the cover.
11. NOTE: Note the location of the ‘‘P’’ clip that
retains the recirculating blower harness.
Remove the recirculating blower.
1 Remove the bolts.
2 Remove the blower
12. Remove the recirculating blower bracket.
1 Remove the bolts.
2 Remove the bracket.
Installation
1. To install, reverse the removal procedure.
414-03B-130
414-03B-130
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
414-03B-131
414-03B-131
High Voltage/Traction Battery — Nickel Metal Hydride
REMOVAL AND INSTALLATION (Continued)
Traction Battery High Voltage Fuse (250A)
Special Tool(s)
Battery Terminal Cap Opener
418-F215
Removal
1. Remove the traction battery. Refer to
2.
WARNING: The nominal voltage of
the traction battery is 300 volts. The buffer
zone must be set up and insulated rubber
gloves and a face shield must be worn.
Failure to follow these precautions may
result in severe personal injury or death.
Observe the EV-specific precautions. Refer to
1 Set up the buffer zone.
2 Test and wear the insulated rubber gloves.
3 Wear the face shield.